Sec. 15.01.200. - Chapter 5, Section 503.2.1 amended—Dimensions.

Chapter 5, Section 503.2.1 of the International Fire Code, 2024 Edition, is amended to read as follows: 503.2.1 Dimensions. Fire apparatus access roads and alleys shall have an unobstructed width of not less than 20 feet (6,096 mm) drivable surface for single-family access and 24 feet (7,315 mm) for duplex and multi-family dwellings access, exclusive of shoulders, except for approved security gates in accordance with Section 503.6, and an unobstructed vertical clearance of not less than 13 feet 6 inches (4,115 mm).

(Ord. No. 52-878, § 20, 1-13-26)