§ 8-21 — International Building Code adopted; amendments
Code of Ordinances of the City of Hernando, Mississippi (Supp. No. 13: codified through Ordinance of August 4, 2026) · Hernando Code of Ordinances § 8-21
Corpus is an independent public-information project, not the official City of Hernando website. Stable reference: corpuslaw.us/code/f4d10dad-e82c-4a69-9c65-4068474032a2
Sec. 8-21. - International Building Code adopted; amendments.
The 2024 International Building Code is adopted with the following appendices: Appendix C, Group U—Agricultural Building; Appendix I, Patio Covers with the following modifications and amendments to the 2024 International Building Code: (1) IBC Modification. When the International Building Code refers to the "applicable governing authority," it shall be deemed to be a reference to the mayor and board of aldermen of the city. When the International Building Code refers to the "code official," it shall mean the person appointed or designated by the mayor and board of aldermen of the city to administer and enforce the provisions of the International Building Code. (2) IBC Amendment No. 1. Delete Section 113 of the 2024 International Building Code in its entirety and substitute in its place, the following: 113.1.1 Appeals. An appeal, variance request or application for approval of alternative methods or materials as described in IBC Section 104.11 shall be made in writing to the building official at the office of planning. The building official shall respond in writing through certified mail within 10 working days of receipt of the request. An appeal of the building official's decision shall be requested in writing to the director of planning at the office of planning. The director of planning shall respond in writing through certified mail within 10 working days of receipt of the request. An appeal of the director of planning decision shall be requested in writing to Planning Commission. The written request for an appeal of this decision shall be submitted to the city clerk Appeals and/or variance request to the requirements of the International Building, Plumbing, Fuel Gas, Mechanical, Energy Conservation Codes, National Electrical Code (NFPA 70) as amended and adopted by the city shall be heard by Board of Aldermen. (3) IBC Amendment No. 2. Amend Chapter 11 of the 2024 International Building Code by adding the following code references at the end of the section: American with Disabilities Act Accessibility Guidelines and the Fair Housing Act where applicable. (4) IBC Amendment No. 3. Amend Section 1406.3 of the 2024 International Building Code by adding section 1406.3.1 as follows: 1406.3.1 Private Balconies. On private balconies where separate tenants are provided and the balcony perimeter walls are less than 50 percent open and constructed of combustible construction, tenant separation requirements at the balcony floor shall be provided. (5) IBC Amendment No. 4. Amend Section 3109 of the 2024 International Building Code by adding section 3109.6 as follows: 3109.6 Ladders and steps. All pools whether public or private shall be provided with a ladder or steps in the shallow end where water depth exceeds 36 inches. In private pools where water depth exceeds 5 feet there shall be ladders, stairs, or underwater benches/swim outs in the deep end. Where manufactured diving equipment shall be used, benches or swim outs shall be recessed or located in a corner. In public pools, there shall be steps or ladders in the shallow end and ladders in the deep end. Ladders, stairs, or underwater benches/swim outs shall be no more than 75 feet apart. (6) IBC Amendment No. 5. Amend Section 202 General Definitions Fire Area, to read as follows: [F] Fire Area. The aggregate floor area enclosed and bounded by firewalls of four hours minimum or, exterior walls of a building. Areas of the building not provided with surrounding walls shall be included in the fire area if such areas are included within the horizontal projection of the roof or floor next above. (7) IBC Amendment No. 6. Amend Chapter 7: Fire and Smoke Protection Features by adding the following: Section: 706.12 Fire Areas. Firewalls separating a single and/or mixed occupancy into different fire areas shall have a fire-resistance rating of not less than four hours. (8) IBC Amendment No. 7. Delete Section 707.3.10 and Table 707.3.10, fire areas entirely. (9) IBC Amendment No. 8. Add Section 901.8.1 to Chapter 9: Fire Protection Systems. [F]Section 901.8.1 Pump Riser Room Access. Fire pump and automatic sprinkler system riser rooms shall be provided with an exterior door and unobstructed passageway large enough to allow removal of the largest piece of equipment. (10) IBC Amendment No. 9. Amend Section 903.2.1.1 Group A-1 to read as follows: [F] 903.2.1.1 Group A-1. An automatic sprinkler system shall be provided for Group A-1 occupancies where one of the following conditions exists: 1. The fire area exceeds 8,000 square feet (743m 2 ); 2. The fire area has an occupant load of 300 or more; 3. The fire area is located on a floor other than a level of exit discharge serving such occupancies; or 4. The fire area contains a multi-theater complex. (11) IBC Amendment No. 10. Amend Section 903.2.1.3 Group A-3 to read as follows: [F] 903.2.1.3 Group A-3. An automatic sprinkler system shall be provided for Group A-3 occupancies where one of the following conditions exists: 1. The fire area exceeds 8,000 square feet (743m 2 ); 2. The fire area has an occupant load of 300 or more; or 3. The fire area is located on a floor other than a level of exit discharge serving such occupancies. (12) IBC Amendment No. 11. Amend Section 903.2.1.4 Group A-4 to read as follows: [F] 903.2.1.4 Group A-4. An automatic sprinkler system shall be provided for Group A-4 occupancies where one of the following conditions exists: 1. The fire area exceeds 8,000 square feet (743m 2 ); 2. The fire area has an occupant load of 300 or more; or 3. The fire area is located on a floor other than a level of exit discharge serving such occupancies. (13) IBC Amendment No. 12. Add Section 903.2.2.1 Group B Business: [F] 903.2.2.1 Group B Business. An automatic sprinkler system shall be provided for Group B occupancies where the fire area exceeds 8,000 square feet (743m 2 ); (14) IBC Amendment No. 13. Amend Section 903.2.3 Group E and Delete Exception. [F] 903.2.3 Group E. An automatic sprinkler system shall be provided for Group E occupancies as follows: 1. Throughout all Group E fire areas 2. Throughout every portion of educational buildings below the lowest level of exit discharge serving that portion of the building. (15) IBC Amendment No. 14. Amend Section 903.2.4 Group F-1 to read as follows: [F] 903.2.4 Group F-1. An automatic sprinkler system shall be provided throughout all buildings containing a Group F-1 occupancy where one of the following conditions exists: 1. A Group F-1 fire area exceeds 8,000 square feet (743m 2 ). 2. A Group F-1 fire area is located more than three stories above grade plane. 3. The combined area of all Group F-1 fire areas on all floors, including any mezzanines, exceeds 8,000 square feet (743m 2 ). 4. A Group F-1 occupancy used for the manufacture of upholstered furniture or mattresses exceeds 2,500 square feet (232 m 2 ). (16) IBC Amendment No. 15. Add the following Section: 903.2.4.2 Group F-2 Factory Industrial F-2 Low-hazard Occupancy. 1. A Group F-2 fire area exceeds 8,000 square feet (743 m 2 ). 2. A Group F-2 fire area is located more than three stories above grade plane. 3. The combined area of all Group F-2 fire areas on all floors, including any mezzanines, exceeds 8,000 square feet (743m 2 ). (17) IBC Amendment No. 16. Amend Section 903.2.7 Group M to read as follows: [F] 903.2.7 Group M. An automatic sprinkler system shall be provided throughout buildings containing a Group M occupancy where one of the following conditions exists: 1. A Group M fire area exceeds 8,000 square feet (743m 2 ). 2. A Group M fire area is located more than three stories above grade plane. 3. The combined area of all Group M fire areas on all floors, including any mezzanines, exceeds 16,000 square feet (1486 m 2 ). 4. A Group M occupancy used for the display and sale of upholstered furniture or mattresses exceeds 5,000 square feet (464 m 2 ). (18) IBC Amendment No. 17. Amend Section 903.2.9 Group S-1 to read as follows: [F] 903.2.9 Group S-1. An automatic sprinkler system shall be provided throughout all buildings containing a Group S-1 occupancy where one of the following conditions exists: 1. A Group S-1 fire area exceeds 8,000 square feet (743m 2 ). 2. A Group S-1 fire area is located more than three stories above grade plane. 3. The combined area of all Group S-1 fire areas on all floors, including any mezzanines, exceeds 16,000 square feet (1486m 2 ). 4. A Group S-1 fire area used for the storage of commercial trucks or buses where the fire area exceeds 5,000 square feet (464 m 2 ). 5. A Group S-1 occupancy used for the storage of upholstered furniture or mattresses exceeds 2,500 square feet (232 m 2 ). (19) IBC Amendment No. 18. Amend Section 903.2.9.1 Repair Garages to read as follows: [F] 903.2.9.1 Repair garages. An automatic sprinkler system shall be provided throughout all buildings used as repair garages in accordance with Section 406, as shown: 1. Buildings having two or more stories above grade plane, including basements, with a fire area containing a repair garage exceeding 8000 square feet (743m 2 ). 2. Buildings no more than one story above grade plane, with a fire area containing a repair garage exceeding 8,000 square feet (743m 2 ). 3. Buildings with repair garages servicing vehicles parked in basements. 4. A Group S-1 fire area used for the repair of commercial trucks or buses where the fire area exceeds 5,000 square feet (464 m 2 ). (20) IBC Amendment No. 19. Amend Section 903.2.10 Group S-2 to read as follows: [F] 903.2.10 Group S-2 enclosed parking garages. An automatic sprinkler system shall be provided throughout buildings classified as enclosed parking garages in accordance with Section 406.4 as follows: 1. Where the fire area of the enclosed parking garage exceeds 8,000 square feet (743m 2 ); or 2. Where the enclosed parking garage is located beneath other groups. Exception: Enclosed parking garages located beneath Group R-3 occupancies. (21) IBC Amendment No. 20. Add Section 903.2.13 [F] Section 903.2.13 Mixed Occupancies. All buildings 8000 square feet or greater fire area not separated by the approved 3-hour fire barrier and/or horizontal assembly set forth in this ordnance shall have a fire sprinkler system. (22) IBC Amendment No. 21. Add Section 903.2.14 [F] Section 903.2.14 Multi-Tenant Occupancy. Every other potential occupancy space shall have a monitored sprinkler cutoff valve and water flow switch installed for accurate response from fire department personnel and to eliminate potential hazard from the entire building being disconnected from water system during construction of future tenant spaces. (23) IBC Amendment No. 22. Add Section 903.4.2.1 [F] 903.4.2.1. All Buildings that are required to have a fire sprinkler system shall provide a minimum of one visible/audible warning device in each tenant space that actuation of the sprinkler system or fire alarm system shall activate the device. (24) IBC Amendment No. 23. Amend Chapter 35 Reference Standards from IECC - 24 International Energy Conservation Code to IECC - 09 International Energy Conservation Code (25) Construction - All hotel/motel occupant types greater than three stories shall be constructed to meet Type II B, or more restrictive options that are considered non-combustible construction types as defined in the International Building Code as adopted. (26) Stair Enclosures- Where buildings are designed and constructed ,pursuant to section 602.5 relating to the construction of combustible Type V buildings, all stair enclosures shall be of two hour non combustible construction having 1½ hour rated opening protection.
(Ord. of 5-20-2014, § 1; Ord. of 2-3-2026(2))
Ask a question about Hernando law
Corpus searches the Hernando sections it holds and shows the ones that match, with their citations. Free, no sign-in.