Sec. 8-25. - International Residential Code adopted; modifications.

The 2024 International Residential Code be adopted with the following appendices: Appendix A - Sizing and Capacity of Gas Piping; Appendix B - Sizing of Venting Systems Serving Appliances with Draft Hoods, Category I Appliances and Appliances Listed for Use With Type B Vents; Appendix C-Exit Terminals of Mechanical Draft and Direct - Vent Systems; Appendix G - Swimming Pools, Spas, and Hot Tubs; Appendix H - Patio Covers; Appendix N - Venting Methods; and Appendix P - Sizing of Water Piping Systems with the following modifications and amendments to the 2024 International Residential Code: (1) IRC Modification. Whenever the International Residential Code refers to the code official it shall mean the person appointed or designated by the municipal governing body to administer and enforce the provisions of the Residential Code. (2) International Residential Building Code. a. IRC (B) Amendment No. 1. Amend Section R112 of the 2024 International Residential Code by deleting sections R112.1 and inserting the following in place of the deleted sections. R112.1. An appeal, variance request or application for approval of alternative methods or materials as described in IBC Section 104.11 shall be made in writing to the building official at the office of planning. The building official shall respond in writing through certified mail within 10 working days of receipt of the request. An appeal of the building official's decision shall be requested in writing to the director of planning at the office of planning. The director of planning shall respond in writing through certified mail within ten working days of receipt of the request. An appeal of the director of planning decision shall be requested in writing to Planning Commission. The appeal shall be submitted to the city clerk. The Appeals and or request for variance to the requirements of the International Residential Building Code shall be heard by Board of Aldermen b. IRC (B) Amendment No. 2. Amend table R301.2(1) to read as follows; Table R301.2(1) Climatic and Geographic Design Criteria Ground Snow Load | Wind Design | Seismic Design Categoryf | Subject to Damage From Speedd (mph) | Topographic effectsk | Weatheringa | Frost line depthb | Termitec 10 inches | 90 | Site specific | D 0 | Moderate | 13 Inches | Very heavy Winter Design Temp | Ice Barrier Underlayment Requiredh | Flood Hazardsg | Air Freezing Indexi | Mean Annual Tempj 20 degrees | No | NFIP | 250 | 60 degrees c. IRC (B) Amendment No. 3. 1. Amend Section R313.2 of the 2024 International Residential Code by adding the following at the end of the paragraph: "Exceeding 6500 sq. ft. under roof" so the amended section will read: R313.2 One- and two-family dwellings automatic fire systems. An automatic residential fire sprinkler system shall be installed in one- and two-family dwellings exceeding 6500 sq. ft. under roof 2. Amend Section R302, Table R302.1(1) of the 2024 International Residential Code as follows: Delete the words "1 hour" in row 1, column 3, for walls with less than five feet of fire separation distance and insert in its place "2 hour." d. IRC (B) Amendment No. 4. Modify Section R301.2.2 number 2 by adding the phrase "however, such detached one and two family dwellings constructed using wood framing in Seismic Design Categories D o , D 1 and D 2 shall be allowed, as an alternative compliance method for meeting the structural requirements of this code's seismic provisions, to comply with the requirement in Section R301.2.2.3.8." at the end of this item, so that when amended the entire section shall read as follows: R301.2.2 Seismic provisions. The seismic provisions of this code shall apply as follows: 1. Townhouse in Seismic Design Categories C, D 0 , D 1 and D 2 . 2. Detached one and two family dwellings in D 0 , D 1 and D 2 , however, such detached one and two family dwellings constructed using wood framing in Seismic Design Categories D 0 , D 1 and D 2 shall be allowed, as an alternative compliance method for meeting the structural requirements of this code's seismic provisions, to comply with the requirement in Section R301.2.2.3.8. e. IRC (B) Amendment No. 5. Add a new Section R301.2.2.3.8 and new Subsections R301.2.2.3.8.1 through R301.2.2.3.8.12 so that when amended, the entire new section and its subsections shall read as follows: R301.2.2.3.8Alternative compliance method for structural requirements. In addition to meeting all the structural requirements for Seismic Design Category C and sections R301.2.2.3.1, R301.2.2.3.6 and R301.2.2.3.7, an alternative compliance method for meeting structural requirements when wood framing is used shall include compliance with the following items. In the event any requirement in this section differs from wind code structural requirements, the more stringent will apply. The alternative compliance method is allowable only when the total wall opening area does not exceed 30 percent of wall area along each of the four main exterior walls, not including exterior walls containing a garage door opening. 1. A minimum of two 24-inch prefabricated shear panels may be installed in any one exterior wall with openings that exceed the 30 percent requirement and still be considered in compliance with the amendment conditions. R301.2.2.3.8.1 Anchorage exterior walls (Sole Plates). Exterior wall sole plates shall be secured to the foundation or framing below by one of the following methods: 1. Foundation: one-half inch (12.7 mm) anchor bolts, with three-inch by three-inch (76 mm by 76 mm) washers, embedded in the foundation a minimum of seven inches (178 mm) in depth. Such anchor bolts are to be placed four feet on center maximum and within 12 inches (305 mm) of the end of each plate section. A minimum of two anchors per plate section is required. 2. Foundation: MASA anchors or equivalent embedded in the foundation and placed at four feet (1219 mm) on center maximum and within 12 inches (305 mm) of the end of each plate section. A minimum of two anchors per plate section is required. 3. Elevated Floors: 10d nails placed at eight inches on center and embedded in a continuous rim board. Rim board depth to match depth of floor framing. Rim board shall be nailed to the end of each floor framing member with three 10d nails. Where floor framing parallels exterior wall, two rim boards shall be provided and nailed per Table R602.3(1). The rim board shall be fastened to wall top plate with metal plates at six feet (1829 mm) on center; installed plate capacity shall equal or exceed 440 pounds. R301.2.2.3.8.2 Anchorage all structural interior walls (Sole Plates). Interior wall framing shall be secured by one of the following methods: 1. Foundation: one-half inch (12.7mm) anchor bolts, with three-inch by three-inch (76 mm by 76 mm) washers, embedded a minimum of 7 inches (178 mm) in depth in the concrete foundation (thickened slab) at 4 feet (1219 mm) on center maximum and within 12 inches (305mm) of the end of each plate section. 2. Foundation: By power actuated fasteners that provide 210 pounds per linear foot shear capacity, placed two feet (610 mm) on center maximum and within 12 inches (305 mm) of each plate section or equivalent means of anchorage. A minimum of two anchors are required per plate section. 3. Elevated Floors: 10d nails placed at eight inches (204 mm) on center and embedded in one of the following: a) Structural wall top plate flush with bottom of floor sheathing; or b) Floor joist parallel with and directly below plate; or c) Blocking, depth to match, placed between floor joists and running the full length of the plate. Blocking to be nailed per Table R602.3(1). R301.2.2.3.8.3 Stud spacing - Exterior walls. All two by four exterior walls shall be a maximum of 16 inch (406 mm) stud spacing up to three stories. Gypcrete flooring or similar cementitous leveling products shall not be used on elevated floors. Exception: Thin-set or other base material required for installation of flooring products in isolated confined spaces such as bathrooms. R301.2.2.3.8.4 Wall sheathing. R301.2.2.3.8.4.1 Exterior wall sheathing. Exterior wall sheathing shall be 7/16inch (11mm) exterior rated OSB or equivalent or 7/16-inch (11mm) plywood minimum. Sheathing is to be fastened every six inches (152 mm) on the edges and 12 inches (305 mm) at intermediate supports. R301.2.2.3.8.4.5 Interior structural wall sheathing. Interior sheathing shall be a minimum of one-half inch (12.7mm) gypsum fastened every seven inches (178 mm) on edges and every seven inches (178 mm) at intermediate supports. R301.2.2.3.8.5 Garage door openings. Brace wall panels are required for garage openings as per Section R602.10.6 of this Code. Exception - An engineered pre-manufactured wall panel is allowed to be used at garage openings. R301.2.2.3.8.6 APA Narrow Wall systems are not permitted. Use of APA narrow wall systems is not permitted for establishing compliance with these requirements. R301.2.2.3.8.7 Connections across floor joist space. 18 gauge galvanized steel coil strapping (ex. CS 18) installed at 48-inch (1219 mm) on center across floor joist space or equivalent is required on all exterior walls and stacked interior structural walls. Strapping shall run vertical along edge of studs and shall be centered on floor joist space. Studs shall be vertically aligned. R301.2.2.3.8.8 Roof framing connections. Roof framing members shall be fastened to wall top plate with 18 gauge galvanized steel clips (ex. H2.5A) or equivalent, not to exceed 48 inches (1219 mm) on center maximum. Provide clips in addition to fastening requirements in Table R602.3(1). This requirement applies to all contact points with load bearing walls. In the event wind fastening requirements differ, the more stringent shall apply. R301.2.2.3.8.9 Shear wall hold downs. Exterior walls: A single hold down shall be installed at each end of each wall over eight feet (2438 mm) in length (two hold downs per wall length). Hold down capacity (P), in pounds, shall be equal to 210 pounds/feet times wall height (P = 210 * H) where (H) is the distance from wall bottom plate to wall top plate. A cut sheet of the hold down type used shall be provided to code enforcement when requested by the Building Official. Cut sheet shall show tested product load rating and manufacturer information. R301.2.2.3.8.10 Opening straps/clips. This section applies only to window and door openings and only to openings located in exterior walls and interior structural walls. Louver, pipe penetrations, dryer vents, and all other wall openings are not required to meet this section unless they exceed four square feet in area. 1. Studs above and below headers and window sill plates: Provide 18 gauge galvanized steel clips (ex. H2.5A) or equivalent at 32 inches (813 mm), top and bottom of studs, minimum two clips per opening width at headers and sills. 2. Headers: Headers shall bear on minimum one ply jack post and be fastened to post with 18 gauge galvanized steel clips (ex. H2.5A), or continuous sheathing from king post to header or sill or equivalent. 3. Window Sill plate: Sill plate shall be end nailed with three 10d nails each end through minimum one ply of king/jack posts, or continuous sheathing from king post to header or sill, or equivalent. 4. King/Jack posts: Provide 20 gauge galvanized steel stud plate connector (ex. SP1) or equivalent from post to wall plate, top and bottom. Post plys shall be nailed together with 10d nails at eight inches (204 mm) on center staggered full height. R301.2.2.3.8.11 Brick veneer. Exterior brick veneer shall not exceed 25 feet (7620 mm) in height above non-combustible foundation. Brick at gable peaks shall not exceed 40 feet (12 192 mm) in height above non-combustible foundation. Exterior brick veneer shall comply with all other applicable Chapter 7 IRC requirements. Interior brick veneer and masonry chimneys shall comply with Chapter 7 IRC requirements. R301.2.2.3.8.12 Floor openings. When floor openings in the second or third floors exceed 15 percent of the ground floor square footage, garage space excluded, they shall be considered as large floor openings. 1. The gross floor area shall be the area bounded by exterior walls. 2. Openings for stairs and egress are excluded from the net floor opening area. 3. Perimeter interior walls bounding a large floor opening shall be considered structural and shall be subject to all requirements as such. If perimeter walls are not present below opening perimeter (i.e. beam and column system is used), the supporting structure shall be engineered. (3) Residential Mechanical. a. IRC (M) Amendment No. 1. Amend Section MI305.1.3 of the 2024 International Residential Code by adding new section as follows: 1305.1.3.2. Access to mechanical equipment located in the attic of one- and two-family dwelling units shall be provided by permanent or pull down stairs. b. IRC (M) Amendment No. 2. Amend Section M1411.3 of the 2024 International Residential Code by adding the following sentence to the end of the paragraph: Units shall drain to a sanitary sewer drain through an indirect waste located within two feet of the equipment, or to an approved french drain which extends two feet below grade and provides eight cubic feet of drain material for a unit three tons (10.6 kW) nominal capacity or less or sixteen cubic feet of drain material for a unit larger than three tons. (4) Residential Electrical. a. IRC (E) Amendment No. 1. Delete Chapter 34 though 43 of the 2024 International Residential Code in its entirety and substitute the following: Residential Electrical Wiring shall be installed incompliance with and according to 2011 NFPA 70, The National Electrical Code. (5) Residential Energy Conservation. R112. An appeal, variance request or application for approval of alternative methods or materials as described in IBC Section 104.11 shall be made in writing to the building official at the office of planning. The building official shall respond in writing through certified mail within ten working days of receipt of the request. An appeal of the building official's decision shall be requested in writing to the director of planning at the office of planning. The director of planning shall respond in writing through certified mail within ten working days of receipt of the request. An appeal of the director of planning decision shall be requested in writing to Planning Commission. An appeal of this decision shall be made to the city clerk. Appeals and or request for variance to the requirements of the International Residential Code as adopted and amended by the city, shall be heard by the construction Board of Aldermen a. IRC (Energy) Amendment No. 1. Amend Table N1102.1.1 (R402.1.1) by deleting the values listed in Zone 3 and inserting in place the following values; Fenestration U-Factor- 0.50 Skylight U-Factor- 0.65 Ceiling R-Value- 30 Frame wall R-Value- 13 Mass Wall R-Value- 5 continuous / 8 cavity Floor R-Value- 19 Basement Wall R-Value- 5 continuous / 13 cavity Slab R-Value and Depth- 0 Crawl Space Wall R-Value- 5 continuous / 13 cavity b. IRC (Energy) Amendment No. 2. Amend Table N1102.1.3 (R402.1.3) by deleting the values listed in Zone 3 and inserting in place the following values; Fenestration U-Factor- 0.50 Skylight U-Factor- 0.65 Ceiling U-Factor- 0.035 Frame wall U-Factor- 0.082 Mass Wall U-Factor- 0.141 Floor U- Factor- 0.047 Basement Wall U-Factor- 0.091 Slab R-Value and Depth- 0 Crawl Space Wall U-Factor 0.136 c. IRC (Energy) Amendment No. 3. Delete Section 1102.4.1.2 (R402.4.1.2) Testing, entirely

(Ord. of 5-20-2014, § 5; Ord. of 2-3-2026(2))

Ask a question about Hernando law

Corpus searches the Hernando sections it holds and shows the ones that match, with their citations. Free, no sign-in.