§ 8-23 — International Plumbing Code adopted; modifications

Code of Ordinances of the City of Hernando, Mississippi (Supp. No. 13: codified through Ordinance of August 4, 2026) · Hernando Code of Ordinances § 8-23

Corpus is an independent public-information project, not the official City of Hernando website. Stable reference: corpuslaw.us/code/e523a779-9ac4-4bb2-9c7b-8164f6424ede

Sec. 8-23. - International Plumbing Code adopted; modifications.

The 2024 International Plumbing Code be adopted with the following appendices: Appendix B - Rates of Rainfall for Various Cities and Appendix E - Sizing of Water Piping Systems with the following modifications and amendments to the 2024 International Plumbing Code: (1) IPC Modification. Whenever the International Plumbing Code refers to the code official it shall mean the person appointed or designated by the municipal governing body to administer and enforce the provisions of the International Plumbing Code. (2) IPC Amendment No. 1. Amend Section 109 of the 2024 International Plumbing Code by deleting sections 113.1 and inserting the following in place of the deleted sections: 113.1 Appeals. An appeal, variance request or application for approval of alternative methods or materials as described in IBC Section 104.11 shall be made in writing to the building official at the office of planning. The building official shall respond in writing through certified mail within 10 working days of receipt of the request. An appeal of the building official's decision shall be requested in writing to the director of planning at the office of planning. The director of planning shall respond in writing through certified mail within ten working days of receipt of the request. An appeal of the director of planning decision shall be requested in writing to Planning Commission. An appeal of this decision shall be submitted to the city clerk. Appeals and or request for variance to the requirements of the International Plumbing Code as adopted and amended by the city, shall be heard by the Board of Aldermen (3) IPC Amendment No. 2. Amend Section 306.1 of the 2024 International Plumbing Code by adding the following section: 306.2.4 Support. Under slab plumbing installations placed on un-compacted fill shall be properly supported in accordance with section 308. (4) IPC Amendment No. 3. Amend Section 403.1 of the 2024 International Plumbing Code by adding exception and table as follows: Exception. A single, unisex, toilet room with one water closet and one lavatory is allowed in the following occupancies when the total area does not exceed the values listed in the table. Occupancy | Maximum Area, Net Square Feet Assembly | 500 Business | 1,500 Mercantile | 1,500 Factory and industrial | 1,500 Storage | 4,500 (5) IPC Amendment No. 4. Amend Section 605 of the 2024 International Plumbing Code by adding the following sentence at the end of the section: 605.5. Water Distribution fittings shall not be placed under slab installations unless prior approval is made with the Code Official. (6) IPC Amendment No. 5. Amend Section 608.1 of the 2024 International Plumbing Code by adding section 608.1.1 as follows: 608.1.1. A backflow prevention device shall be required in all new and existing buildings when the building official determines that there is a hazard of contamination of the potable water supply. (7) IPC Amendment No. 6. Amend Section 608.16.5 of the 2024 International Plumbing Code by adding section 608.16.5.1 as follows: 608.16.5.1. A Reduced, Pressure, Backflow Preventer and all components shall be installed to meet the following conditions: A. A valve shall be placed within close proximity of the water meter. B. A minimum of schedule 40 service pipe shall be installed from the meter to the backflow preventer. C. The schedule 40 service pipe shall be buried at a minimum depth of 12 inches. D. There shall be a minimum of 12 inches of gravel at the bottom of the backflow preventer. E. Each backflow preventer shall be tested and certified by an individual certified by the State of Tennessee to test such devices. The test results shall be on site at the time of inspection (8) IPC Amendment No. 7. Amend Section 903.1 of the 2024 International Plumbing Code by inserting the number 10 in place of the bracketed word [number]. (9) IPC Amendment No. 8. Amend Section 913.4 and Table 913.4 of the 2024 International Plumbing Code, by changing the minimum diameter of stack vents and vent stacks to two inches. (10) Amend 410.2 to Occupant loads of 100.

(Ord. of 5-20-2014, § 3; Ord. of 2-3-2026(2))

Ask a question about Hernando law

Corpus searches the Hernando sections it holds and shows the ones that match, with their citations. Free, no sign-in.