§ 8-24 — International Mechanical Code adopted; modifications

Code of Ordinances of the City of Hernando, Mississippi (Supp. No. 13: codified through Ordinance of August 4, 2026) · Hernando Code of Ordinances § 8-24

Corpus is an independent public-information project, not the official City of Hernando website. Stable reference: corpuslaw.us/code/ba870b46-1747-4d31-ba23-259a46304df0

Sec. 8-24. - International Mechanical Code adopted; modifications.

The 2024 International Mechanical Code be adopted with the following modifications and amendments to the 2024 International Mechanical Code: (1) IMC modification. Whenever the International Mechanical Code refers to the "code official" it shall mean the person appointed or designated by the municipal governing body to administer and enforce the provisions of the Mechanical Code. (2) IMC Amendment No. 1. Amend Section 109 of the 2024 International Mechanical Code by deleting sections 109.1.1, 109.2, 109.3, 109.4, 109.5 and 109.6 and inserting the following in place of the deleted sections. 109.2 Appeals. An appeal, variance request or application for approval of alternative methods or materials as described in IBC Section 104.11 shall be made in writing to the building official at the office of planning. The building official shall respond in writing through certified mail within 10 working days of receipt of the request. An appeal of the building official's decision shall be requested in writing to the director of planning at the office of planning. The director of planning shall respond in writing through certified mail within ten working days of receipt of the request. An appeal of the director of planning decision shall be requested in writing to Planning Commission. The appeal shall be to the city clerk. Appeals and or request for variance to the requirements of the International Mechanical Code as adopted and amended by the city, shall be heard by the Board of Aldermen (3) IMC Amendment No. 2. Amend Section 506.3.2.5 to read as follows: 506.3.2.5 Grease duct test. Prior to the use or concealment of any portion of a grease duct system, a leakage test shall be performed. Ducts shall be considered to be concealed where installed in shafts or covered by coatings or wraps that prevent the ductwork from being visually inspected on all sides. The permit holder shall be responsible to provide the necessary equipment and perform the grease duct leakage test. All intake and exhaust terminations shall be sealed and smoke emitters, sufficient to positively charge the system, shall be dropped in to the system including the hood to duct connection. The duct shall be permitted to be tested in sections, provided that every joint is tested. For listed factory-built grease duct, the test shall be limited to duct joints assembled in the field and shall exclude factory welds.

(Ord. of 5-20-2014, § 4; Ord. of 2-3-2026(2))

Ask a question about Hernando law

Corpus searches the Hernando sections it holds and shows the ones that match, with their citations. Free, no sign-in.