§ 8-22 — International Fuel Gas Code adopted; modifications
Code of Ordinances of the City of Hernando, Mississippi (Supp. No. 13: codified through Ordinance of August 4, 2026) · Hernando Code of Ordinances § 8-22
Corpus is an independent public-information project, not the official City of Hernando website. Stable reference: corpuslaw.us/code/5db37814-09b7-42cb-a97a-aabb485a015a
Sec. 8-22. - International Fuel Gas Code adopted; modifications.
The 2024 International Fuel Gas Code be adopted with the following appendices: Appendix A - Sizing and Capacities of Gas Piping; Appendix B - Sizing of Venting Systems Serving Appliances Equipped with Draft Hoods, and Category I Appliances and Appliances; and Appendix C - Exit Terminals of Mechanical and Direct Vent Venting Systems with the following modifications and amendments to the 2024 International Fuel Gas Code: (1) IFGC Modification. Whenever the International Fuel Gas Code refers to the "code official" it shall mean the person appointed or designated by the municipal governing body to administer and enforce the provisions of the Gas Code. (2) IFGC Amendment No. 1. Amend Section 112 of the 2024 International Fuel Gas Code by deleting sections 112.2, 112.3, 112.4 and inserting the following in place of the deleted sections. Appeals. An appeal, variance request or application for approval of alternative methods or materials as described in IBC Section 109.11 shall be made in writing to the building official at the office of planning. The building official shall respond in writing through certified mail within 10 working days of receipt of the request. An appeal of the building official's decision shall be requested in writing to the director of planning at the office of planning. The director of planning shall respond in writing through certified mail within 10 working days of receipt of the request. An appeal of the director of planning decision shall be requested in writing to Planning Commission. The request shall be submitted to the city clerk. Appeals and or request for variance to the requirements of the International Fuel Gas Code as adopted and amended by the city, shall be heard by the Board of Aldermen (3) IFGC Amendment No. 2. Amend the 2024 International Fuel Gas Code Section 406.4.1 by deleting the existing language and substituting the following: 406.4.1 Method of testing. Low pressure gas piping (two psig or less) shall withstand a pressure of 30 psig for a period of not less than 10 minutes without showing any drop in pressure. All high pressure gas piping must have a minimum of 100 psig test.
(Ord. of 5-20-2014, § 2; Ord. of 2-3-2026(2))
Ask a question about Hernando law
Corpus searches the Hernando sections it holds and shows the ones that match, with their citations. Free, no sign-in.