§ 8-27 — International Fire Code adopted; modifications
Code of Ordinances of the City of Hernando, Mississippi (Supp. No. 13: codified through Ordinance of August 4, 2026) · Hernando Code of Ordinances § 8-27
Corpus is an independent public-information project, not the official City of Hernando website. Stable reference: corpuslaw.us/code/1da1cb1e-1cb5-4d9a-8d67-68e5e2e988a6
Sec. 8-27. - International Fire Code adopted; modifications.
The 2024 International Fire Code be adopted with the following appendix: Appendix C - Fire Hydrant Locations and Distribution Appendix B - Fire-Flow Requirements for Buildings, Appendix D - Fire Apparatus Access Roads, Appendix E - Hazard Categories, Appendix F - Hazard Ranking, Appendix H - Hazardous Materials Management Plan (HMMP) and Hazardous Materials Inventory Statement (HMIS) Instruction, Appendix I - Fire Protection Systems - Noncompliant Conditions and with the following modifications and amendments to the 2024 International Fire Code: (1) IFC Amendment No. 1. a. Amend Section 108 to read as follows: Section 108. An appeal, variance request or application for approval of alternative methods or materials as described in IBC Section 104.11 shall be made in writing to the Fire Marshal's Office. The Deputy Fire Marshall shall respond in writing through certified mail within 10 working days of receipt of the request. An appeal of the Deputy Fire Marshal's decision shall be requested in writing to the Fire Marshal. The fire marshal shall respond in writing through certified mail within ten working days of receipt of the request. An appeal of the fire marshal's decision shall be requested in writing to Planning Commission. The appeal of this decision shall be submitted to the city clerk. Appeals and or request for variance to the requirements of the International Fire Code as adopted and amended by the city, shall be heard by the Board of Aldermen. b. Amend Section 202 General Definitions Fire Area: [B] Fire area. The aggregate floor area enclosed and bounded by firewalls of four hours minimum, exterior walls of a building. Areas of the building not provided with surrounding walls shall be included in the fire area if such areas are included within the horizontal projection of the roof or floor next above. (2) IFC Amendment No. 2. Amend Section 506.1 where required to read as follows: 506.1 Where required. Where access to or within a structure or an area is restricted because of secured openings or where immediate access is necessary for life-saving or fire-fighting purposes, the fire code official is authorized to require a key box to be installed by the property owner in a location approved by the Fire Official. The key box shall be of an approved type and shall contain keys to gain necessary access as required by the fire code official. Manufacture specifications shall be used to determine number of keys to be allowed to be stored in box. Due consideration shall be given to box size needed. In addition a master key system shall be required on all commercial buildings. (3) IFC Amendment No. 3. Amend Section 506.1.1 Locks to read as follows: 506.1.1 Locks. An approved lock shall be installed by the property owner on gates or similar barriers when required by the fire code official. Two- position electric override key switch shall be installed by the property owner for emergency access to gated communities, apartment complexes, parking garages and industrial gated areas and to control electrical equipment vital to emergency operations. (4) IFC Amendment No. 4. Add Section 705 Fire areas Firewalls: 705 Fire Areas Firewalls. The firewalls separating a single and/or mixed occupancy into different fire areas shall have a fire-resistance rating of not less than 4-hours. (5) IFC Amendment No. 5. Add Section 901.8.1. [B] Section 901.8.1 Pump Riser Room Access. Fire pump and automatic sprinkler system riser rooms shall be provided with an exterior door and unobstructed passageway large enough to allow removal of the largest piece of equipment. (6) IFC Amendment No. 6. Amend Section 903.2.1.1 Group A-1 to read as follows: [B] 903.2.1.1 Group A-1. An automatic sprinkler system shall be provided for Group A-1 occupancies where one of the following conditions exists: 1. The fire area exceeds 8,000 square (743m 2 ); 2. The fire area has an occupant load of 300 or more; 3. The fire area is located on a floor other than a level of exit discharge serving such occupancies; or 4. The fire area contains a multi-theater complex. (7) IFC Amendment No. 7. Amend Section 903.2.1.3 Group A-3 to read as follows: [B] 903.2.1.3 Group A-3. An automatic sprinkler system shall be provided for Group A-3 occupancies where one of the following conditions exists: 1. The fire area exceeds 8,000 square feet (743m 2 ); 2. The fire area has an occupant load of 300 or more; or 3. The fire area is located on a floor other than a level of exit discharge serving such occupancies. (8) IFC Amendment No. 8. Amend Section 903.2.1.4 Group A-4 to read as follows: [B] 903.2.1.4 Group A-4. An automatic sprinkler system shall be provided for Group A-4 occupancies where one of the following conditions exists: 1. The fire area exceeds 8,000 square feet (743m 2 ); 2. The fire area has an occupant load of 300 or more; or 3. The fire area is located on a floor other than a level of exit discharge serving such occupancies. (9) IFC Amendment No. 9. Add Section 903.2.2.1 Group B Business [B] 903.2.2.1 Group B Business. An automatic sprinkler system shall be provided for Group B occupancies where the fire area exceeds 8,000 square feet (743m 2 ); (10) IFC Amendment No. 10. Amend Section 903.2.3 Group E and Delete Exception. [B] 903.2.3 Group E. An automatic sprinkler system shall be provided for Group E occupancies as follows: 1. Throughout all Group E fire areas. 2. Throughout every portion of educational buildings below the lowest level of exit discharge serving that portion of the building. (11) IFC Amendment No. 11. Amend Section 903.2.4 Group F-1 to read as follows: [B] 903.2.4 Group F-1. An automatic sprinkler system shall be provided throughout all buildings containing a Group F-1 occupancy where one of the following conditions exists: 1. A Group F-1 fire area exceeds 8,000 square feet (743m 2 ). 2. A Group F-1 fire area is located more than three stories above grade plane. 3. The combined area of all Group F-1 fire areas on all floors, including any mezzanines, exceeds 8,000 square feet (743m 2 ). 4. A Group F-1 occupancy used for the manufacture of upholstered furniture or mattresses exceeds 2,500 square feet (232 m 2 ). (12) IFC Amendment No. 12. Add Section 903.2.4.2 Group F-2. [B] 903.2.4.2 Group F-2 Factory Industrial F-2 Low-hazard Occupancy. 1. A Group F-2 fire area exceeds 8,000 square feet (1,115 m 2 ). 2. A Group F-2 fire area is located more than three stories above grade plane. 3. The combined area of all Group F-2 fire areas on all floors, including any mezzanines, exceeds 8,000 square feet (2,230 m 2 ). (13) IFC Amendment No. 13. Amend Section 903.2.7 Group M to read as follows: [B] 903.2.7 Group M. An automatic sprinkler system shall be provided throughout buildings containing a Group M occupancy where one of the following conditions exists: 1. A Group M fire area exceeds 8,000 square feet (743m 2 ). 2. A Group M fire area is located more than three stories above grade plane. 3. The combined area of all Group M fire areas on all floors, including any mezzanines, exceeds 16,000 square feet (1,486m 2 ). 4. A Group M occupancy used for the display and sale of upholstered furniture or mattresses exceeds 5,000 square feet (464 m 2 ). (14) IFC Amendment No. 14. Amend Section 903.2.9 Group S-1 to read as follows: [B] 903.2.9 Group S-1. An automatic sprinkler system shall be provided throughout all buildings containing a Group S-1 occupancy where one of the following conditions exists: 1. A Group S-1 fire area exceeds 8,000 square feet (743 m 2 ). 2. A Group S-1 fire area is located more than three stories above grade plane. 3. The combined area of all Group S-1 fire areas on all floors, including any mezzanines, exceeds 16,000 square feet (1,486 m 2 ). 4. A Group S-1 fire area used for the storage of commercial trucks or buses where the fire area exceeds 5,000 square feet (464 m 2 ). 5. A Group S-1 occupancy used for the storage of upholstered furniture or mattresses exceeds 2,500 square feet (232 m 2 ). (15) IFC Amendment No. 15. Amend Section 903.2.9.1 Repair Garages to read as follows: [B] 903.2.9.1 Repair garages. An automatic sprinkler system shall be provided throughout all buildings used as repair garages in accordance with Section 406, as shown: 1. Buildings having two or more stories above grade plane, including basements, with a fire area containing a repair garage exceeding 8,000 square feet (743 m 2 ). 2. Buildings no more than one story above grade plane, with a fire area containing a repair garage exceeding 8,000 square feet (743 m 2 ). 3. Buildings with repair garages servicing vehicles parked in basements. 4. A Group S-1 fire area used for the repair of commercial trucks or buses where the fire area exceeds 5,000 square feet (464 m 2 ). (16) IFC Amendment No. 16. Amend Section 903.2.10 Group S-2 to read as follows: [B] 903.2.10 Group S-2 enclosed parking garages. An automatic sprinkler system shall be provided throughout buildings classified as enclosed parking garages in accordance with Section 406.4 as follows: 1. Where the fire area of the enclosed parking garage exceeds 8,000 square feet (743 m 2 ); or 2. Where the enclosed parking garage is located beneath other groups. Exception: Enclosed parking garages located beneath Group R-3 occupancies. (17) IFC Amendment No. 17. Add Section 903.2.13 [B] Section 903.2.13 Mixed Occupancies. All buildings 8,000 square feet or greater fire area not separated by the approved 4-hour fire barrier and/or horizontal assembly set forth in this ordinance shall have a fire sprinkler system. (18) IFC Amendment No. 18. Add Section 903.2.14 [B] Section 903.2.14 Multi-Tenant Occupancy. Every other potential occupancy space shall have a monitored sprinkler cutoff valve and water flow switch installed for accurate response from fire department personnel and to eliminate potential hazard from the entire building being disconnected from water system during construction of future tenant spaces. (19) IFC Amendment No. 19. Amend Section 903.3.8 to read as follows: 903.3.7 Fire department connections. The location of fire department connections shall be approved by the fire code official. All fire department connections shall be a five-inch storz connection on a 30 degree elbow, placed no less than one and a half times the height of the building away, in an area approved by the fire code official. The fire department connection shall be placed within 100 feet of a hydrant. (20) IFC Amendment No. 20. Add Section 903.4.2.1 [F] 903.4.2.1. All Buildings that are required to have a fire sprinkler system shall provide a minimum of one visible/audible warning device in each tenant space that actuation of the sprinkler system or fire alarm system shall activate the device. (21) IFC Amendment No. 21. (a) A licensed fire protection contractor licensed is required to install an automatic extinguishing system must install all piping within a building and to a point five (5) feet outside the building. Only contractors approved to install fire protection sprinkler systems/ fire main loop shall install piping from a point five (5) feet outside a building to the water provider's connection. Maintenance of piping and fire hydrants shall be performed by the contractor in compliance with the regulations of the Mississippi State Board of Contractors, for the duration of the building project. Loop systems for yard piping are required for increased reliability and improved hydraulics. Loop systems should be sectionalized by placing valves at branches and at strategic locations to minimize the extent of impairments.
(Ord. of 5-20-2014, § 7; Ord. of 2-3-2026(2))
Ask a question about Hernando law
Corpus searches the Hernando sections it holds and shows the ones that match, with their citations. Free, no sign-in.
