Sec. 8-26. - National Electrical Code adopted; modifications.

The 2023 National Electrical Code (NEC) be adopted with the following modifications and amendments: (1) NEC Modification. Whenever the National Electrical Code refers to the "code official" it shall mean the person appointed or designated by the municipal governing body to administer and enforce the provisions of the Electrical Code. (2) NEC Amendment No. 1. Amend Article 210, Section 210.12(B) of the 2008 National Electrical Code by adding the following exception; Exception: Arc-fault circuit interrupters, combination type, shall be required for all bedrooms and in all other rooms shall be optional. In addition, arc-fault interrupters will not be required for garage door openers. (3) NEC Amendment No. 2. Appeals. An appeal, variance request or application for approval of alternative methods or materials as described in IBC Section 104.11 shall be made in writing to the Building Official. The building official shall respond in writing within ten working days of receipt of the request. An appeal of the building official's decision shall be requested in writing to the director of planning. The director of planning shall respond in writing within ten working days of receipt of the request. An appeal of the director of planning decision shall be requested in writing to Planning Commission. Appeals and or request for variance to the requirements of the National Electrical Code as adopted and amended by the city, shall be heard by the Board of Aldermen. (4) Delete Section 210.8 in it's entirety and replace it with the 2011 NEC language for Section 210.8 (5) Delete 230.85 in it's entirety (6) Amend section 330.21 by adding "In commercial settings, MC Cable is required" (7) Amending 334.12 by adding (11) "In commercial settings, MC Cable is required" (8) Deleting 334.10 (2), (3), (4), and (5)

(Ord. of 2-3-2026(2))

Ask a question about Hernando law

Corpus searches the Hernando sections it holds and shows the ones that match, with their citations. Free, no sign-in.