§ 62-79 — Justification for system extensions and modifications
Code of Ordinances, City of Concord, North Carolina (Supp. 53 Update 2: codified through Ordinance No. 26-83, enacted August 13, 2026 (online updated September 15, 2026)) · Concord Code of Ordinances § 62-79
Corpus is an independent public-information project, not the official City of Concord website. Stable reference: corpuslaw.us/code/dcfb5215-d16e-4372-ac50-2f9b48c92b3f
Sec. 62-79. - Justification for system extensions and modifications.
(a) Concord Utilities recognizes four justifications for the extension or modification of the Concord Water Distribution and/or Wastewater Collection Systems. (1) Extensions and modifications for the health, safety, and welfare of the public. The Concord Water Distribution or Wastewater Collection System may be extended or modified for the purpose of providing public utility access to persons when their existing system has failed and is resulting in a demonstrated health risk to them and/or the general public. (2) Extensions and modifications for the fulfillment of the Capital Improvement Plan. The city shall provide and maintain certain basic components of the Concord Utilities. These components include treatment facilities, water booster pump stations, wastewater pump stations, water storage tanks, sewer outfall mains, and water transmission mains. Any extensions or modifications to these components shall be constructed and/or improved according to a Capital Improvement Plan (C.I.P.) that is reviewed and approved by the city council. The city may also extend or modify water distribution mains and sewer collection mains within the Concord Utilities for the purpose of serving existing residential dwellings or vacant lots, which are zoned for residential development, within the municipal limits of the City of Concord. Upon approval by the city council, the city may also extend water transmission and/or distribution lines or sewer collection and/or outfall mains to industrial or commercial properties meeting the criteria of the city's adopted economic development incentive policy. The city's financial participation in utility extension and modification projects is subject to the availability of funds and other qualifications. (3) Extensions and modifications for involuntary annexation areas. The city shall meet all requirements related to annexations as prescribed by N.C. General Statute Chapter 160A, Article 4A, Part 3. Concord Utilities shall provide the same level of service to newly-annexed areas that is available to the remainder of the city, as provided by the city's adopted ordinances and policies. Therefore, the city may extend or modify the Concord Utilities for the purpose of providing the appropriate level of service to involuntary annexation areas. (4) Extensions and modifications for subdivisions and private development. The Concord Utilities may be extended or modified for the purpose of providing service to subdivisions and private developments subject to the provisions of this article. (b) Concord Utilities recognizes the following justifications for the addition and/or modification of public lift stations/force mains of the Concord Wastewater Collection Systems to serve the subbasin of which the lift station discharges into. (1) Lift stations may be allowed where they are a feasible alternative to either a small, permanent treatment facility or a temporary solution for a new development. (2) Concord may add additional regional pump stations to provide for effective and efficient flow of wastewater throughout the system. (3) Concord may, on a case-by-case basis, consider requests to accept new developer funded lift stations in the situations described below: a. The lift station can be eliminated by a project or combination of projects, all of which are included for funding in the approved 5-year CIP. The lift station can be eliminated by a project being done under a reimbursable program, and the funds have been made available to Concord for construction. b. The proposed lift station is at an appropriate location and has adequate capacity or expansion capacity to serve as a permanent or long-term facility, and gravity service is cost prohibitive or not possible due to other circumstances. If developer can provide documentation that the cost of a gravity sewer exceeds the cost of a wastewater lift station-force main pursuant to Title 15A NCAC 2T, Concord Code of Ordinance Chapter 62, Article 3, and Concord's Pump Station-Force Main technical specification and details. The developer shall submit a sealed cost estimate of the projected gravity sewer and lift station, Concord shall evaluate the documentation for possible authorization. c. The construction of the proposed lift station would include elimination of one or more existing lift stations. d. The construction of the proposed lift station would facilitate significant progress toward achievement of land use goals and strategies described by current, officially approved planning documents, and no other reasonable options are available for service. (4) In all cases, the receiving system must have available capacity to carry the proposed lift station discharge. Any upgrades required shall be the responsibility of the customer requesting the lift station.
(Ord. No. 04-17, § 1, 3-11-2004; Ord. No. 26-36, § 1, 3-12-2026)
Ask a question about Concord law
Corpus searches the Concord sections it holds and shows the ones that match, with their citations. Free, no sign-in.