§ 62-98 — Minimum design criteria

Code of Ordinances, City of Concord, North Carolina (Supp. 53 Update 2: codified through Ordinance No. 26-83, enacted August 13, 2026 (online updated September 15, 2026)) · Concord Code of Ordinances § 62-98

Corpus is an independent public-information project, not the official City of Concord website. Stable reference: corpuslaw.us/code/1824b143-12ec-454e-92d9-2fd2807de674

Sec. 62-98. - Minimum design criteria.

The following design criteria shall be adhered to for all public and private extensions to or modifications to the city's water distribution system and wastewater collection system. All utilities requiring a permit pursuant to this article shall be designed following good engineering practices. All engineering plans shall include but not be limited to the following information: (1) General requirements for engineering plans. a. A general location map, a north arrow, a scale, a plan view of all proposed water and sanitary sewer lines (including gravity lines and force mains), a center-of-pipe profile view of all proposed sanitary sewer lines (including gravity lines and force mains), and a center-of-pipe profile view of all waterlines with diameters 12 inches and greater. The plan and profile view of the same portion of line shall be provided on the same engineering plan sheet. b. Road names and state road numbers, existing and proposed utilities, existing names and location of water-bodies, the 100-year flood elevation, existing and proposed rights-of-way and easements, elevation control markers and monuments, utility stationing, existing and proposed topography at two-foot increments, and the proximity of the proposed infrastructure to all other utilities and natural features within 200 feet. c. Water distribution line and wastewater collection line stationing shall be separate from roadway stationing. d. Engineering plans shall be signed, sealed, and dated by the engineer. (2) Applicable standards. Designs shall conform to the following minimum design standards: a. The North Carolina Administrative Code; b. The design standards in the Standard Specifications for Wastewater Collection and Water Distribution Construction for Cabarrus County; c. Any additional standards as determined by this article or the director of engineering; d. Cross connection control, in accordance with the Backflow Prevention and Cross Connection Control Manual and section 62-161, shall be provided. (3) Rights-of-way/easements. All utility rights-of-way/easements shall meet the following standards: a. Rights-of-way and easements shall be granted, dedicated, and recorded in accordance with the city's current rights-of-way, easements, and encroachments policy. b. Water distribution lines and wastewater collection lines that are not located within a road right-of-way shall be located within a public utility right-of-way/easement 1. The minimum utility right-of-way/easement width shall be 30 feet. 2. Rights-of-way greater than 30 feet shall be provided when required by the director of engineering. 3. Every portion of the water distribution system extension and wastewater collection system extension or modification shall be accessible by city maintenance crews and equipment within the utility rights-of-way/easement. An all weather travel surface and a minimum slope of eight percent or flatter and side slopes of two percent or flatter must be provided within the utility rights-of-way/easement. When access through the utility rights-of-way/easement is not possible, the director of engineering may approve a maintenance/access easement. All maintenance/access easements must be clearly indicated on the plans and legally conveyed to the city. The maintenance/access easement shall have an all weather travel surface with a minimum slope of eight percent or flatter and side slopes of two percent or flatter with a horizontal curve radius that does not exceed the turning capabilities of the city equipment. (4) Locations and separations. The location of all utilities shall meet the following standards and the required horizontal and/or vertical separation distance shall be noted at the appropriate station on the engineering plans. a. A minimum horizontal separation of five feet shall be maintained between any type of maintenance obstruction and the city's water distribution lines, wastewater collection lines, and associated appurtenances, unless an exception is granted as outlined in section 62-100. Greater separation distances may be required as specified by federal, state, or local regulations. b. A minimum vertical separation of two feet shall be maintained between any type of maintenance obstruction, including but not limited to any other utility provider's lines or equipment, and the city water distribution lines, wastewater collection lines, and associated appurtenances, unless an exception is granted as outlined in section 62-100. If an exception is granted, a minimum vertical separation of one foot must be maintained and the city water distribution lines, wastewater collection lines, and associated appurtenances shall be constructed of ductile iron pipe or an approved ferrous material with joints that are equivalent to potable water main standards for a distance of ten feet on either side of the point of crossing. Greater separation distances may be required as specified by federal, state, or local regulations. c. A minimum horizontal separation of ten feet shall be maintained between the city water distribution system and wastewater collection lines, and associated appurtenances, unless an exception is granted as outlined in section 62-100. d. In areas where utilities are proposed along new roadways subject to the city's development ordinances, water distribution lines and wastewater collection lines shall be located in accordance with the city's current utility corridor plan, or as specified by the director of engineering. e. Manholes and cleanouts shall not be located within any feature conveying or pooling stormwater. f. Water meters and valve vaults shall not be located within any feature conveying or pooling stormwater. (5) Cover and material standards. The water and sewer system extensions shall meet or exceed the following depth standards: a. Three feet minimum cover shall be provided for water distribution systems and wastewater collection systems extensions and/or modifications unless an exception is granted as outlined in section 62-100. If an exception is granted, the water distribution systems and wastewater collection systems extensions and/or modifications must maintain at least 30 inches of cover and be constructed of ductile iron pipe or an approved ferrous material. b. Maximum depth of cover for non-ferrous pipe shall be limited to 18 feet. Non-ferrous pipe with a proposed depth of cover exceeding 12 feet shall require the submission of bearing capacity documentation and the supporting design calculations and shall be subject to approval by the director of engineering. The documentation and design calculations shall address the bearing capacity of the proposed pipe and its ability to withstand the dead and live loads. The design shall include adequate documentation and a standard detail, which adequately addresses the bedding requirements for the pipe. c. Ferrous material shall be provided for all proposed water and sewer system extensions that have a depth of cover exceeding 18 feet. All ferrous pipe with a proposed depth of cover exceeding 18 feet shall require the submission of bearing capacity documentation and the supporting design calculations and shall be subject to approval by the director of engineering. The documentation and design calculations shall adequately address the bearing capacity of the proposed ferrous pipe and its ability to withstand the dead and live loads. The design shall include adequate documentation and the proposed standard detail, which adequately satisfies the bedding requirements for the pipe. (6) Pipe standards. a. All wastewater collection system mains shall be sized to accommodate potential wastewater flow from the entire drainage basin based on current zoning and/or land use designations. b. Water distribution system extensions or modifications that are 12 inches or greater in diameter shall be constructed of ductile iron pipe with joints that are equivalent to potable water main standards. c. Fire hydrant legs shall be constructed of six inch ductile iron pipe with restrained joints that are equivalent to potable water main standards. (7) Slope standards. Eight-inch diameter wastewater collection system lines shall be designed and installed at a slope equal to or exceeding six-tenths of one percent except on dead-end lines and lines where low flows are expected. Minimum slope on such lines that are 18 inch or less in diameter shall be one percent. (8) Manhole standards. a. If the sanitary sewer lines entering and exiting a manhole are separated by 225°—270° or 90°—135°, the invert-in and invert-out elevations shall have a vertical separation of at least five-tenths of one foot. b. Five-foot diameter inside drop manholes shall be provided where invert separations equal two feet or greater and a 12-inch diameter pipe or smaller is proposed. If three 12-inch diameter or smaller drops are needed at a manhole, a six-foot inside drop manhole shall be provided. If the invert separation is two feet or greater and a pipe diameter larger than 12-inches is proposed, an outside drop manhole shall be provided. c. Wastewater collection system manhole rim elevations must be set to conform to the street and shoulder final grade elevation within public or private road rights-of-way. All other wastewater collection system manhole rim elevations shall be at least two feet above final grade. Wastewater collection system manholes located within the 100-year flood elevation shall be set such that the rim elevation is either one foot above the 100-year flood elevation but not more than three feet above final grade or two feet above final grade and watertight with sealed manhole covers and screened vent pipes set at least one foot above the 100-year flood elevation. d. Wastewater collection system manholes shall be vented every 1,000 feet or at every other manhole, whichever yields the greater number of vents. (9) Wastewater pump station standard. All wastewater pump stations shall be designed according to the city's standard wastewater pump station specification. (10) Service laterals. Service laterals shall meet the following standards. a. Sewer service cleanouts shall be located at the edge of the right-of-way. b. Sewer service cleanouts shall have brass caps with glued bi-threaded couplings. c. Sewer service laterals that discharge directly into a manhole shall discharge into the manhole trough via direct piping that extends to the main trough or via a manufactured service trough at a one percent grade. d. When water and sewer service laterals are extended from mains within the road right-of-way, sewer service laterals shall be located at the center of the lot and water service laterals shall be located five feet to the right of the sewer service lateral.

(Ord. No. 04-17, § 1, 3-11-2004; Ord. No. 05-13, § 7, 3-10-2005; Ord. No. 05-95, § 1, 10-13-2005; Ord. No. 05-113, § 6, 12-8-2005; Ord. No. 12-117, § 1, 11-8-2012; Ord. No. 21-19, § 5, 3-11-2021; Ord. No. 26-41, § 2, 5-14-2026)

Ask a question about Concord law

Corpus searches the Concord sections it holds and shows the ones that match, with their citations. Free, no sign-in.