Section II — Determination of storm runoff
Code of Ordinances of the City of Edmond, Oklahoma (Codified through Ordinance No. 4097, enacted August 10, 2026 (Supp. No. 40)) · Edmond Code of Ordinances tit. 23, App. - Standard Drainage Policy, Section II
Corpus is an independent public-information project, not the official City of Edmond website. Stable reference: corpuslaw.us/code/36c96b0b-11e8-4d16-879f-3b36196bded3
Section II. - Determination of storm runoff.
GENERAL. Numerous methods of runoff computation are available on which the design of storm drainage and flood control systems may be based. The Rational Method will be accepted as adequate for drainage areas up to 40 acres. For larger areas, the U.S. Army Corps of Engineers Hydraulic Engineering Center HEC-1 or other engineering programs or methods acceptable to the City Engineer shall be used. Any hydrological soil group data to be used when computing runoff shall be determined from the most current edition of the Oklahoma County, Oklahoma Soil Survey provided by the United States Department of Agriculture Natural Resources Conservation Service. RATIONAL METHOD OF RUNOFF COMPUTATION (A) Runoff Coefficient "C": The runoff coefficients shall be chosen to represent the integrated effects of infiltration, detention storage, evaporation, retention, flow routing, and interception. The "C" values are provided in Table 2.1, Runoff Coefficients for Use in the Rational Formula. (B) Rainfall Intensity (I): The average rainfall rate in inches per hour considered for a particular drainage basin or sub-basin and selected on the basis of design rainfall duration and design frequency or occurrence. (1) Intensity duration curves acceptable for Edmond are shown on Figure 2.1. The formula used to generate the curve is: Rainfall Intensity Formula I = a/(t d + b) c Where I = Average Rainfall Intensity, inches/hour T d = Rainfall Duration (or Time of Concentration), minutes a, b, c = Variable values from the following table: ZONE II RAINFALL FREQUENCY 2 Year | 5 Year | 10 Year | 25 Year | 50 Year | 100 Year a = 56.43 | a = 72 | a = 82 | a = 95 | a = 108 | a = 120 b = 11.5 | b = 15 | b = 15 | b = 15 | b = 15 | b = 15 c = 0.810 | c = 0.80 | c = 0.80 | c = 0.80 | c = 0.80 | c = 0.80 (2) The time of concentration is the time required for the entire watershed to contribute runoff to the point of interest. Street flow shall be considered as being in an open paved channel. An acceptable formula for use in determining overland flow travel time is: Time = K (L .37 /S .2 ) L = Length of Flow in Feet S = Average Slope in Feet/Foot K = Constant for Character of Surface Values of K: Pavement | .37 Bare Soil | .60 Poor Grass | .90 Average Grass | 1.00 Dense Grass | 1.13 An acceptable formula for determining channel flow time is: Time = K (L 2 /S) .385 Values of K: Curbed street .0035 Concrete Lined Channel .006 Sodded Swale .008 Bar Ditch .012 The time of flow in a closed conduit is the quotient of the length of the conduit and velocity of flow as computed using the hydraulic factors of the conduit. Manning's Equation is acceptable for analyzing open channel flows in prismatic channels without backwater control and for analyzing free water surface conduit flows. The use of Manning's Equation for sizing culverts at street crossings shall not be acceptable. (C) Drainage Area: The size and shape of the watershed must be determined. Drainage areas shall be determined through the use of planimetric topographic maps, supplemented by field surveys. A drainage area map shall be provided for each project. The drainage area contributing to the system being designed and drainage sub-area(s) contributing to each inlet point shall be identified. The outlines of the drainage divides must follow actual lines rather than artificial land divisions. TABLE 2.1 Runoff Coefficients for Use in the Rational Formula LAND USE | BASIN SLOPE Slope < 2% | Slope >= 2% Single Family Residence < ½ Acre | .55 | .65 Single Family Residence >= ½ Acre | .45 | .55 Multi Family | .60 | .70. Apartments | .75 | .85 Commercial | .90 | .95 Parks, Golf Courses | .35 | .45 Undeveloped | .30 | .40 [image omitted; see the official code]
Ask a question about Edmond law
Corpus searches the Edmond sections it holds and shows the ones that match, with their citations. Free, no sign-in.