Section V. - Open drainage channels.
NATURAL DRAINAGE FLOW. The creation of swales, alteration of small channel capacity or direction, changing of ground cover, and the lining of existing channels with other material natural or man-produced, may be necessary in some parts of the system to achieve the objectives of this standard. OPEN STORM DRAINAGE REQUIREMENTS (A) All land adjoining open natural or improved storm drainage channels having an elevation below the 100-year flood elevation of the channel shall be dedicated drainage easement for the purpose of providing a zone of protection to all property owners. To facilitate future maintenance, the entire width of the channel and channel banks shall be covered by the same drainage easement. Such channels in developments shall be platted as Common Area and have a maintenance program carried out by the property owners association. (B) All drainage easements platted for the purpose of conveying stormwater above ground shall remain clear of obstructions and encroachments. Prohibited obstructions and encroachments shall include, but are not limited to, fences that block or inhibit the flow of water such as those made of brick or wood panels, swimming pools, driveways, mechanical and electrical equipment, storage sheds, and retaining walls. (C) Any channel improvements shall be approved by the City Engineer prior to the commencement of any work thereon. (D) Whenever channel improvements are carried out, sodding, backsloping, cribbing and other bank protection shall be designed and constructed to control siltation and erosion for the anticipated conditions and flow resulting from a 100 year frequency rainfall. (See Section IX.) (E) Any channel grading shall be such that water will not gather in pools. (F) Drainage easements sufficient in width to provide a buffer and provide working room for construction and access for channel maintenance shall be provided. (G) For an unimproved channel, the width of the drainage easement shall be wide enough to satisfy (F) above as well as to provide enough area to flatten the slope of the bank of the channel 3.5:1 (horizontally:vertically) to allow for the remediation of any future bank erosion. (H) All drainage swales, channels, berms, and other drainage improvements shown on the approved plans shall be constructed prior to the acceptance of the Final Plat. (I) Common Areas set aside for the purposes of stormwater detention and/or conveyance provide an integral part of the stormwater design of the area and shall remain intact for perpetuity and shall not be parceled, split, altered, diminished, or subdivided. This restriction shall also be included on the Final Plat filed of record. DESIGN CONSIDERATIONS (A) Channels should be trapezoidal in shape and on as flat a grade as possible without causing ponding. (B) The use of Mannings Equation in the calculations of hydraulic characteristics of open channel flows in prismatic channels without backwater control will be acceptable. When analyzing natural channels or when analyzing any overland conveyance system that has downstream control that could affect the 100 year event water surface elevations, the use of the HEC-RAS (U.S. Army Corps of Engineers Hydrologic Engineering Center River Analysis System) modeling program or other approved water surface profile modeling program shall be required. The "n" value(s) used for channels shall be based on the individual channel characteristics. When submitting calculations, include the source for the "n" value. (C) Constructed Channel Geometry: The minimum bottom width shall be 4' with side slopes not steeper than 3.5:1 (horizontally:vertically) for sodded sections and a minimum bottom width of 3' with side slopes of not steeper than 1:1 for paved or rocklined sections. Care must be exercised by the engineer to provide a safe design in relation to public areas. (D) Flow Velocities in Channels: Velocities shall not exceed 4 fps for sections sodded in grass. Velocities in concrete lined or paved sections shall not exceed 15 fps. The dissipation of energy shall be required at the confluence of improved channels with natural channels through the use of energy dissipaters, stilling basins, etc. (E) Trickle Channels: All channels altered or improved from the natural state and all drainage swales shall have a paved trickle channel to prevent erosion, permanently set the flowline, and facilitate maintenance. Sodding or other methods of erosion control shall be required adjacent to the paved trickle channel. (F) Concrete Flumes: Concrete flumes shall be allowed as overflow protection for stormsewer systems and in lieu of enclosed pipe to drain areas not exceeding two (2) acres in size. All concrete flumes shall extend to the rear of adjacent lots, have scour protection at their point of discharge, and shall discharge into a dedicated drainage area or channel without creating drainage or erosion problems. 1. Concrete flumes that serve as overflow protection at a sump-position stormsewer system shall be designed for the 100 year storm event flow under the conditions that all upstream inlets and grates are experiencing clogging in accordance with the STD-400 clogging factors and the sump position inlets / grates are totally clogged. The weir length of the entrance to the flume shall be sufficiently sized to convey that flow from the street gutter to the flume without allowing overtopping of the street curb or exceeding street water depth design criteria. 2. Concrete flumes that serve as the primary conveyance avenue in a sump position shall be designed for the 100 year storm event flow under the conditions that all upstream inlets and grates are clogged. The weir length of the entrance to the flume shall be sufficiently sized to convey that flow from the street gutter to the flume without allowing overtopping of the street curb or exceeding street water depth design criteria. 3. A flume on grade where the gutter velocity for the 100 year storm event exceeds 5 fps shall not be allowed as an acceptable method to remove flow from the street due to the high likelihood that the flume entrance will be bypassed by the flow. 4. The weir length of the entrance to a flume on grade shall be designed and accounted for when calculating the amount of flow intercepted by the flume. (G) Bar ditches (often referred to as "drainage ditches") are an acceptable method to convey stormwater runoff in rural paving section design. All bar ditches and driveway culverts shall be designed by the engineer to convey the 100 year storm event. The minimum acceptable driveway culvert diameter is 15". The maintenance of the bar ditch is the responsibility of the property owner. It is encouraged that bar ditches in residential developments have a maintenance program carried out by the property owners association. (H) Reinforced concrete box structures shall have an apron reinforced with rebar. The apron shall be tied to the box structure with rebar and have a toe wall. Adequately sized riprap shall protect the end of the apron and toe wall from scour during the 100 year storm event. Energy dissipaters also shall be used where riprap alone is inadequate to reduce discharge velocities. Sandstone boulders or blocks shall not be used as riprap or energy dissipaters. The reinforced concrete box structure shall be designed to have a minimum freeboard at its inlet from the 100 year storm event water surface elevation to its low chord equal to 15% of the box culvert rise or 2', whichever is less, to help compensate for potential blockage from debris during flooding. The use of Manning's Equation for sizing reinforced concrete box structures at street crossings shall not be acceptable. (I) Span bridges shall be designed to have a minimum freeboard at the inlet from the 100 year storm event water surface elevation to its low chord equal to 15% of the structure's rise or 1', whichever is less. The use of Manning's Equation for sizing span bridges at street crossings shall not be acceptable. (J) All other culverts shall be designed to have a minimum freeboard at the inlet from the 100 year storm event water surface elevation to its low chord equal to 15% of its rise or 2', whichever is less. The use of Manning's Equation for sizing culverts at street crossings shall not be acceptable.
Ask a question about Edmond law
Corpus searches the Edmond sections it holds and shows the ones that match, with their citations. Free, no sign-in.