Section IV — Enclosed stormsewer
Code of Ordinances of the City of Edmond, Oklahoma (Codified through Ordinance No. 4097, enacted August 10, 2026 (Supp. No. 40)) · Edmond Code of Ordinances tit. 23, App. - Standard Drainage Policy, Section IV
Corpus is an independent public-information project, not the official City of Edmond website. Stable reference: corpuslaw.us/code/d40e9e71-73f2-40be-89df-fff8cc8287f3
Section IV. - Enclosed stormsewer.
GENERAL: The use of the Manning Equation or the use of appropriate charts or nomographs in the design of stormsewers will be considered acceptable. Investigations of the capacity of all existing structures on the waterway shall be made. In addition, runoff from storms exceeding the design storm shall be anticipated by the developer and disposed of with minimum damages to surrounding property. The stormsewer must be accessible for maintenance. DESIGN CRITERIA (A) Pipes which are a part of the stormsewer system shall have a minimum diameter of fifteen (15) inches. (B) Enclosed storm drains will be designed for open-channel flow. (C) Minimum Grades: The slope shall be such to maintain a minimum velocity of 2.5 fps. (D) Acceptable Roughness coefficient "n" for stormsewers: Materials of Construction | Design Coefficient Mannings "n" Box Culverts | .013 Concrete Pipe | .012 Annular Plain Corrugated Metal Pipe | .024 Helical Plain Corrugated Metal Pipe | .016 Coated Corrugated Metal Pipe | As approved by City Engineer (E) General rules to be observed: 1. Do not discharge a larger pipe into a smaller one. 2. At change in pipe size, match top of pipe. 3. A one (1) foot freeboard shall be maintained below the proposed finish grade through the stormsewer system. The submittal of energy calculations shall be required on any reach of a system which exceeds 500 linear feet, on the total system that exceeds 1500 linear feet, and/or on a reach of a system which has an elevation change exceeding ten (10) feet. (F) Manhole Locations: Manholes shall be located at intervals not to exceed 350 feet for pipe sizes 42" or less. Above 42", manholes shall be located as determined by the City Engineer. Manholes shall be located at conduit junctions, changes of grade, changes of alignment, and changes in conduit size. (G) Pipe Connections: The use of one material to extend a stormsewer constructed of a different material shall not be allowed except at manholes, junction boxes, or inlets. (H) Pipe Laid on Curves: Degree of curvature shall be as per manufacturer's recommendations. (I) All stormsewer outlets shall have erosion protection provided by headwalls, flared end sections, curtain walls, or other approved outlet protection. (J) All stormsewer pipe under pavement shall be "O-ringed" reinforced concrete pipe. (K) Water-tight seals shall be required for all stormsewer pipe in the right-of-way. (L) A minimum of 2' of cover is required for stormsewer pipe. (M) All stormsewer shall be analyzed for the existence of tailwater conditions during the 100 year storm event. If tailwater is present, the stormsewer shall be designed to adequately compensate for this situation. The calculations or other documentation demonstrating that the tailwater check has been made shall be submitted. (N) A drainage easement of satisfactory width to provide working room for construction and maintenance shall be provided for all stormsewers with the minimum width of the easement being 15'. The presence of any bedding materials, backfill, and the depth of pipe also shall be taken into consideration. INLET SYSTEM (A) Inlet design and location in street sections must be compatible with the allowable depth of water on the street section. (B) Inlet location shall not interfere with vehicular or pedestrian traffic. (C) Whenever possible, inlets shall intercept water before it reaches a pedestrian crosswalk or street intersection. (D) Inlets shall not be located in a curb radius. Where existing conditions exist that require an inlet in the radius, the radius shall not be less than 38 feet. (E) Inlets shall be located to prevent water from minor streets spilling over and flooding major streets. (F) All hoods in a sump condition shall have 8" openings with the gutter lowered to accommodate the inlet. Transition section shall be 10' in each direction. (G) Where a curbed street crosses a bridge or reinforced concrete box structure, gutter flow shall be intercepted and not allowed to flow onto the structure. (H) Inlets on non-arterial streets shall be installed at all low points with sufficient inlet design to ensure the ponding depth does not exceed 5" in a 100 year storm event for a standard 6" barrier curbed or standard 6" mountable curbed street. For non-arterial streets with nonstandard curbs, the maximum 100 year storm event water surface elevation in the street at all low points shall be limited to provide the same inches of freeboard between the water surface elevation and the top of the curb that is required in the first part of this section. For arterial or section line streets, ponding depth shall not exceed 4" in a 100 year storm event. (I) All stormsewer systems located at a low point ("sump")shall provide for an emergency overflow channel with a designated drainage easement sufficiently sized to contain within its boundaries the 100 year storm event runoff under the assumed conditions that the sump position stormsewer inlets / grates are 100% blocked, and in addition provide sufficient working room for future maintenance. (J) Inlet Capacities. No method of determining capacity is prescribed in this standard. Theoretical capacities using clear water in nomograph form have been published by various sources such as the American Society of Civil Engineers (ASCE) & Highway Research Board. When using nomographs, submit the source along with drainage calculations. Due to the potential for clogging and changes in street cross section due to future street resurfacing, the following efficiency factors shall be applied: Inlet | Condition | Efficiency Curb Opening | Continuous grade | 0.8 Sump | 0.8 Grate | Continuous grade | 0.6 Sump | 0.5 Transverse bars | 0.5 Combination | Continuous grade | 0.7 Sump | 0. 7 Street slope, street cross-slope, and velocities shall be taken into account when sizing inlets and grates with their efficiencies reduced accordingly. The receiving stormsewer pipes shall be sized for flows to which the inlet and grate clogging factors have not been applied. (K) Any inlet grates over which a bicyclist can ride shall be of a design considered bicycle safe.
Ask a question about Edmond law
Corpus searches the Edmond sections it holds and shows the ones that match, with their citations. Free, no sign-in.