§ 3-905.14 — Pipe sizing
Code of the City of Harrisburg, Pennsylvania · Harrisburg Code § 3-905.14
Corpus is an independent public-information project, not the official City of Harrisburg website. Stable reference: corpuslaw.us/code/cf9a972e-962f-40b3-ae80-d690d4e8c663
§ 3-905.14: Pipe sizing.
A. Piping shall be designed in accordance with NFPA 13R and NFPA 13D. If more than one design discharge is required, the pipe sizing procedure shall be prepared for each design discharge, except that when piping is sized hydraulically, calculations shall be made in accordance with the methods described in NFPA 13, Standards for the Installation of Sprinkler Systems. B. Minimum size pipe shall be 3/4 of an inch for copper, blazemaster and polybutelene and one inch for steel. C. To size piping for systems connected to a City water supply, the following approximate method is acceptable: (1) Establish system flow rate in accordance with § 3-905.10. (2) Determine water pressure in the street. (3) Select pipe sizes. (4) Deduct meter pressure losses, if any. (5) Deduct pressure loss for elevation building height above street in feet times 0.434 equals psi. (6) Deduct pressure losses from City main to control valve (manifold assembly including any backflow prevention if required) by the total lengths of pipe in feet. (7) Deduct pressure losses for piping within building by the total length in feet of each size pipe between the control valve (manifold assembly) and the farthest sprinkler. (8) Deduct valve and fitting pressure losses. Count valves and fittings from the control valve to the highest, hydraulically most remote point, determine the equivalent length for each size by the factors for the pipe use and total these values. (9) In multilevel buildings, Steps 1 through 7 shall be repeated to size piping for each floor. (10) If the remaining pressure is less than the operating pressure established by the testing laboratory for the sprinkler being used, a redesign is necessary. If this pressure is higher than required, smaller piping may be used when justified in calculations. (11) The remaining piping shall be sized the same as the piping to the farthest sprinkler unless smaller sizes are justified by calculations. D. To size piping for systems with an elevated tank, pump or pump-tank combination, determine the pressure at the water supply outlet and proceed through Steps 3, 7, 8, 9, 10 and 11 of Subsection C. E. Pipe configurations may be looped, gridded, straight run or a combination thereof.
Ask a question about Harrisburg law
Corpus searches the Harrisburg sections it holds and shows the ones that match, with their citations. Free, no sign-in.