§ 3-905.18 — Levels of protection

Code of the City of Harrisburg, Pennsylvania · Harrisburg Code § 3-905.18

Corpus is an independent public-information project, not the official City of Harrisburg website. Stable reference: corpuslaw.us/code/7b13e263-035e-4e24-bf56-906ede0d6fc4

§ 3-905.18: Levels of protection.

A. The responsibility for properly maintaining a sprinkler system is the obligation of the owner or manager, who shall understand the sprinkler system operation. A monthly maintenance program shall follow these steps: (1) Inspect all sprinklers visually to ensure against obstruction of spray. (2) Inspect all valves to assure that they are opened. (3) Test water flow devices. (4) Test the alarm system. Note: When it appears likely that the test will result in a response from the Fire Bureau, notification shall be made to the Fire Bureau prior to any testing of the system. (5) Test pumps, where employed. (6) Check the pressure of air used with dry systems. (7) Check water level in tanks. (8) Take care to see that sprinklers are not painted either at the time of installation or subsequent redecoration. When painting sprinkler piping, or painting in areas next to sprinklers, the sprinklers may be covered with a bag which shall be immediately removed after painting has been completed for that area. (9) Protect any sprinkler heads located in areas subject to damage with a cage or similar device. (10) Maintain a record or log of such inspections and make available the same upon the request of the Fire Chief. B. When a tank is used for domestic and fire protection purposes, a low-water alarm actuated when the water level falls below 110% of the minimum quantity as required per the discharge design and domestic usage requirements shall be installed. C. Decorative painting of a residential sprinkler must be distinguished from the temperature identification colors as referenced in Section 3.16.6 of NFPA 13-1987, Standard for the Installation of Sprinkler Systems. D. Alarms connected to the water flow devices shall be of sufficient intensity to be clearly audible in all bedrooms over background noise levels with all intervening doors closed. The tests of the audibility level shall be conducted with household equipment which may be in operation at night and in full operation, i.e., window air conditioners, television, stereo, room humidifiers and/or room dehumidifiers, etc. E. The following shall provide guidance for location of sprinklers near ceiling obstructions. Where beams, light fixtures, sloped ceilings and other obstructions occur, additional sprinklers may be necessary to achieve proper response and distribution. Guidance may also be obtained from the manufacturer. F. Maximum distance from sprinkler deflector to bottom of ceiling obstruction. Distance from Sprinkler to Side of Ceiling Obstruction | Maximum Distance from Sprinkler Deflector to Bottom of Ceiling Obstruction 6 inches or less | Not permitted 6 inches to less than 1 foot | 0 inch 1 foot to less than 2 feet | 1 inch 2 feet to less than 2 feet 6 inches | 2 inches 2 feet 6 inches to less than 3 feet | 3 inches 3 feet to less than 3 feet 6 inches | 4 inches 3 feet 6 inches to less than 4 feet | 6 inches 4 feet to less than 4 feet 6 inches | 7 inches 4 feet 6 inches to less than 5 feet | 9 inches 5 feet to less than 5 feet 6 inches | 11 inches 5 feet 6 inches to less than 6 feet | 14 inches G. As indicated throughout this chapter, light and ordinary hazard structures shall follow the criteria as defined in NFPA 13-1987, Standard for the Installation of Sprinkler Systems. H. When approved plastic piping is used in domestic sprinkler systems, all threaded fittings used for testing purposes shall be of CPVC, PVC, or copper. No black iron nipples shall be used on plastic female fittings for testing purposes. I. All sprinkler head threads are to receive either a coating of teflon liquid dope acceptable to the plastic being utilized or a second wrapping of teflon tape prior to installation. J. All domestic sprinkler systems must be installed by certified personnel, i.e., licensed plumber or licensed sprinkler installer. However, the final connection to the water supply shall be completed by a licensed master plumber who has been certified by the Bureau of Codes Enforcement. K. At least three spare sprinkler heads of each type utilized, temperature rating and orifice size used in the system shall be kept on the premises. When fused sprinklers are replaced by the owner or others, care shall be taken to assure that the replacement sprinkler has the same operating characteristics. L. The following items are required on drawings for domestic sprinklers: (1) Establish sprinkler system under the City of Harrisburg requirements. (2) Indicate layout of head location, pipe layout, location of cutoff, tie-in, switch bell, location of commode if used for circulating, location of bleeder valve and line, and Fire Department connection. (3) Description notes: Fill out blanks and attach (a) through (t) to all drawings. (a) Type of head _____ () pendant () sidewall () both. (b) Type of pipe _______________. (c) Type of fastening of pipe _______________. (d) Type of backflow if used _________________. (e) Size of main from street _______________. (f) Size of main sprinkler line _______________. (g) Size(s) of branch line(s) _______________. (h) Type and degree of heads in mechanical room _______________. (i) Note: No branch lines are to exceed 25 feet on circulating system. (j) Flow test of sprinkler system to be certified before drywall. (k) Copy of hydraulic calculations to be provided. (l) Calculations to be based on gpm flow test at highest elevation and worst condition. (m) If separate calculations for each group of buildings, note on drawings and calculations. (n) Pipe in attic shall be laid as close as possible to the ceiling. (o) Escutcheons shall be used when heads are near light fixtures or beams so that spray pattern is not obstructed or two heads are to be used. (p) Any changes in these drawings or in the event any unfinished rooms are contemplated, all changes shall be submitted for approval. (q) Mechanical rooms to have 165° to 212° F. commercial-type sprinkler heads. (r) No exposed piping to sprinklered areas. (s) Piping is to be protected from freezing. (t) All sprinkler drops are to be screwed into place with no nails to be utilized. M. The following items are required for valves and manifold assembly: (1) Incoming water supply from street line or other supply. (2) Gate valve, meter assembly (and possible backflow preventer) as required by local water authority. (3) Iron pipe "T." (4) Domestic supply. (5) Union with iron pipe standard. (6) One-quarter-turn full port gate valve (iron pipe standard). (7) Watts 601 (iron pipe standard) check valve or equivalent. [Note: Double valve assembly (backflow preventer) required where a Fire Department connection is utilized.] (8) McDonnell & Miller FS4-3F series flow switch or equivalent. (9) Drains piped outside of structure. (10) Pressure-relief valve Watts 530c50 with one-half-inch fittings or equivalent. (11) Cross-connection. (12) Pressure gauge rated at least 25 psi over static pressure. (13) Manifold assembly. (14) Century two-and-one-half-inch swivel Fire Bureau connection or equivalent. (15) Connection to sprinkler system piping and sprinkler heads. (16) Nipple length extends five pipe diameters.

Ask a question about Harrisburg law

Corpus searches the Harrisburg sections it holds and shows the ones that match, with their citations. Free, no sign-in.