For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 5.12 — Standards for Multi-Family Residential Dwellings in Non-Residential Zoning Districts

Code of the City of Arlington, Texas (City Secretary chapter PDFs as posted 2026-11-07, each current through the ordinance named on its cover, with the City Secretary's adopted-not-yet-codified Ordinances 25-063, 25-069, 25-073, 25-074, 25-075, 25-084, 26-003, 26-004, 26-019, 26-024 and 26-027 applied; Anti-Discrimination chapter not included) · Arlington City Code, Unified Development Code Chapter, § 5.12

Corpus is an independent public-information project, not the official City of Arlington website. Stable reference: corpuslaw.us/code/78c97766-6a40-4275-aa59-283f010b54a5

5.12. STANDARDS FOR MULTI-FAMILY RESIDENTIAL DWELLINGS IN NON-RESIDENTIAL ZONING DISTRICTS

5.12.1. PURPOSE A. The purpose of these standards is to improve the appearance and functionality of multi-family development in non-residential zoning districts, recognizing the importance to design in the economic success of urban areas, the need to be more efficient in the use of land, and the need to ensure the adequate protection of the surrounding area. These standards are intended to: 1. Improve the quality of life of residents of multi-family residential dwellings; 2. Promote sensitive design and planning of multi-family housing units that preserves or improves the characteristics of surrounding development; 3. Provide a distinctive architectural character in new multi-family residential developments that avoids featureless design, large building masses, and repetition of façades within a single development; 4. Promote building design, placement, and orientation that contributes to a sense of neighborhood and community; 5. Complement or be compatible with the surrounding uses and community facilities; 6. Contribute to, enhance, or promote the welfare of the area and adjacent properties; and 7. Advance the goals of adopted neighborhood or area plans, ensuring the proposed development contributes to cohesive community design, preserves natural features where appropriate, and reinforces connectivity and walkability. 5.12.2. APPLICABILITY A. These standards are applicable to new construction or development of multi-family dwelling units in all non-residential zoning districts, except: 1. When multi-family dwellings are not permitted by Section 3.2, Supplemental Use Standards. 2. In Form-Based Zoning Districts (FBZDs) – Standards in Article 13 apply. B. Applicable overlay district standards contained in Section 2.4, Overlay Districts, must be met, such as streetscape and public realm standards. 5.12.3. NON-RESIDENTIAL BUILDING CONVERSION A. This section shall apply to an existing building used for office, retail, or warehouse uses that: 1. Proposes to convert at least 65 percent of the building for multi-family dwellings or mixed-use dwellings; 2. At least 65 percent of each floor of the building is fit for occupancy; and 3. Was constructed and with a Certificate of Occupancy issued at least 5 years before the proposed date to start the conversion. B. The following regulations are prohibited in connection with the use, development construction, or occupancy of such building and conversion: 1. The preparation of a traffic impact analysis or other study relating to the effect the proposed converted building would have on traffic or traffic operations; 2. The construction of improvements or payment of a fee in connection with mitigating traffic effects related to the proposed converted building; 3. The provision of additional parking spaces, other than the parking spaces that already exist on the site of the proposed converted building; 4. The extension, upgrade, replacement, or oversizing of a utility facility except as necessary to provide the minimum capacity needed to serve the proposed converted building; 5. Design requirement, including a requirement related to the exterior, windows, internal environment of a building, or interior space dimensions of an apartment, that is more restrictive than the applicable minimum standard under the International Building Code as adopted as a municipal commercial building code under Texas Local Government Code, Section 214.216; and 6. Impact fees, unless the land on which the building is located was already subject to an impact fee before a building permit related to the conversation was filed with the Zoning Administrator. 5.12.4. SITE DESIGN AND BUILDING ORGANIZATION A. Tree Preservation 1. Must comply with Section 5.2.3, Tree Preservation and Replacement. B. Common Open Space 1. For multi-family residential buildings with a gross floor area greater than 20,000 and up to 50,000 square feet: 7 percent of total gross site area must be preserved for common open spaces. 2. For multi-family residential buildings with a gross floor area greater than 50,000 square feet: 10 percent of total gross site area must be preserved for common open spaces. 3. Common open spaces must comply with Section 5.10.3, Common Open Space Standards, of this Code. C. Building Orientation and Common Open Space Common open space shall be provided in accordance with Section 5.10, Common Open Space, and this section. 1. Large open space should be the fundamental organizing element of the site. Common open space should be well defined by buildings and streets. Buildings should be oriented in such a way as to create courtyards and open space areas. 2. Large existing trees and other natural features should be integrated into the open space. 3. Common open space should be centralized and directly accessible to a majority of the surrounding units. Where possible, it should be linked to adjacent parks, paths, and open space areas. 4. The open space counted towards the Open Space Area calculation shall be useable areas and not riparian areas or slopes exceeding 3:1. D. Building Separation 1. Building separation must comply with Section 5.5.4.D., Building Separation for Multi-Family Development. 2. In no instance shall a separation standard require a setback from a property line be more than 25 feet. In such instance, the setback or separation requirement shall be reduced to 25 feet. E. Site Amenities 1. In conjunction with the common open space requirements, all multi-family projects must provide site amenities from the table below for the residents. 2. Site amenities must be located equitably throughout the development. 3. Within 75 feet of a single-family residential use, all site amenities located above the ground floor must be contained within an enclosed building. 4. Within 75 feet of a single-family residential use, all active site amenities located on the ground floor must be contained within an enclosed building. Active amenities include swimming pools, playgrounds, and sport courts. 5. Multi-family residential projects must provide the type and number of amenities according to Table 5.12-1 and 5.12-2. | TABLE 5.12-1: Site Amenities Table – Multi-Family Dwelling Districts | Tier 1 3 amenities must be provided from this table | Amenity | | | Standards Dog Park  Minimum 1,200 sq ft fenced area with (a) pet waste station, (b) shaded bench, and (c) pet washing station (outdoor spigot with drain or elevated tub).  Must not be located within 75 feet of a single-family residential use. Bicycle storage and repair  Covered structure with space for minimum 1 bike per 5 station units and a fixed repair stand with basic tools and tire pump. Library and reading area  Furnished interior space (min. 150 sq ft) with built-in bookshelves and seating for at least 4. Game/Media room and  Shared-use indoor room (min. 300 sq ft) with flexible meeting spaces seating and one built-in screen/projector or monitor  Office center and maker Shared-use indoor room with at least 2 workstations, high- space speed internet, and one specialty workstation (e.g., 3D printer, sewing machine, or crafting bench).  Fitness center with sauna Fitness room of at least 500 sq ft plus either a dedicated or steam room sauna or steam room with separate ventilation. | TABLE 5.12-2: Site Amenities Table – Multi-Family Dwelling Districts | Tier 2 2 amenities must be provided from this table | Amenity | | | Standards Swimming pool and  Swimming pool: Minimum 400 sq ft in-water surface area shaded children’s play and 600 sq ft adjacent deck. Includes: (a) 4-ft enclosure area (required for projects with self-latching gate, (b) shade structure over part of with more than 80 units) deck, (c) shaded seating for at least 4, and (d) ADA accessibility.  Children’s play area: Minimum 800 sq ft outdoor area with: (a) shaded play structure with at least 2 interactive elements, (b) impact-absorbing surface, (c) 2+ benches, and (d) fencing if adjacent to parking or drive aisles. Project-wide  Continuous 10-ft-wide loop trail (min. 1,000 linear feet) jogging/walking trails with pet waste stations every 300 ft; must connect at least 3 parts of the site. Rooftop lounge  Minimum 500 sq ft rooftop space with built-in seating and shading (e.g., pergola, canopy); ADA-accessible.  Centralized courtyard Minimum 1,200 sq ft common courtyard with at least one with prominent artistic or water feature and seating integrated fountain/art/sculpture into the design.  Community garden with At least 300 sq ft of raised planting beds, water access, and shed a 40 sq ft storage shed with tools. Natural open space with  Minimum 3,000 sq ft open area with: (a) native plantings, outdoor features (b) 2+ shaded benches, (c) shaded playground (unless already required), and (d) shaded outdoor kitchen or grill. Sports Court  Full-size court for one of the following: tennis, basketball, volleyball, or pickleball, with appropriate surfacing, striping, and perimeter fencing (as applicable). The Zoning Administrator may approve a half-court if site constraints, design integration, or unit count warrant a reduced configuration. F. Setbacks and Buffers 1. In no instance shall a buffer or setback require more than 25 feet between a property line and a building. G. Access 1. New multi-family developments with 100 or more units shall take primary access from an arterial street and shall comply with the following standards: a. A minimum of one secondary point of ingress/egress into a multi-family development may be required for public safety access. b. No vehicular access from a multi-family development shall be provided on a local street serving existing single-family detached development; however, secondary vehicle access for public safety vehicles may be provided onto local streets. 2. New multi-family development with fewer than 100 units may take primary access from a major collector street, if approved by the Zoning Administrator. 3. See Section 5.2.2.B.6, Landscape at Site Entries for Multi-Family Developments for site entry landscaping standards. 4. All stairwells and stairways shall be integrated into the design of the building and include a security gate at any exterior point of entry. 5. All secured buildings and communal areas must be accessible for emergency access, such as the use of Knox boxes, and include security cameras and related equipment. H. Off-Street Parking Standards and Location In addition to all applicable parking standards in Section 5.4, Off-Street Parking and Loading, the following standards must be met. In the event of a conflict, this section controls. 1. Minimum number of parking spaces must comply with section 5.4.3, Off- Street Parking Standards. 2. In no instance shall parking spaces required for residential purposes be used for shared parking calculations. 3. At least 80 percent of the required number of parking spaces must be provided in covered parking. At least 50 percent of these parking spaces must be located in an enclosed garage. 4. No parking shall be between a building and the street right-of-way. I. Parking Lot Landscaping. 1. Uncovered Spaces. All uncovered parking spaces must be located within 50 feet of a shade tree. 2. Large Shade Trees. Newly planted trees within the surface parking lot shall only include Shade Trees from the City’s Approved Plant List. J. Accessory Parking and Loading Standards 1. An accessible rideshare pick-up and drop-off location must be provided outside secured gates at the primary access point. 2. At least 15 percent of all required parking spaces must include electric vehicle charging stations. Such stations must be associated with an uncovered parking space accessible to multi-family tenants and may be counted toward required parking. Off-premise signage shall not be permitted. K. Energy Saving and Environmental Measures 1. Provide at least two passive measures, such as: a. Building orientation directing a majority of windows and doors away from long durations of sun exposure, b. Utilizing preserved trees for shading the proposed building facades, c. Working with existing topography, or d. Minimizing impervious surfaces by careful building footprint/hardscape placement. 2. Provide at least two active measures, such as: a. Solar roofs for the carports and low VOC materials/coatings; b. DarkSky compliant outdoor lighting; c. Rainwater reclamation; d. Bioswales to catch and filter water runoff; or e. Energy efficiency smart home devices in all residences and communal areas. 3. Additional active or passive measures may be approved by the Zoning Administrator. 4. The site plan must include an energy saving and environmental note as to how the development complies with these measures and anticipated impact. The Zoning Administrator shall review this note to determine compliance. 5.12.5. BUILDING DESIGN A. Building Height 1. Building height must comply with Section 4.1.6.E, Special Height Limitations in Non-Residential Zoning Districts. B. Building Length 1. The maximum length of any multi-family building shall be 180 feet. C. 360-Degree Architecture 1. All sides of a multi-family building shall display a similar level of quality and architectural detailing as on the front elevation. D. Design of Multiple Buildings 1. Design of multiple buildings must comply with Section 5.5.4.F.8, Design of Multiple Buildings. E. Building Mass and Horizontal Articulation 1. Each elevation greater than 50 feet in length, measured horizontally, must incorporate: a. horizontal articulations having a combined change in articulation of at least 30 percent of the length of the elevation. 2. The elevations of all multi-family buildings must be articulated through the incorporation of at least six or more of the following: a. Bay or box windows; b. Porches or covered entries that are proportional to the size of the building; c. Dormers; d. Awnings or canopies; e. Structural offsets a minimum of four feet from the principal plane of the façade; f. Accent materials such as brick, stone, or stucco with banding highlights; g. Ornamental or decorative window grills and shutters; h. Variation in window sizes and shapes; i. Vertical elements such as towers or building end-caps that demarcate building modules; or j. Other features as approved by the Zoning Administrator. 3. The height of any part of a multi-family building shall not exceed 45 feet if the building is located within 75 feet of a property zoned or used for single-family residential. Buildings and parts of buildings located more than 75 feet away are not subject to Section 4.1.6.E., Special Height Limitations in Non- Residential Zoning Districts. 4. Multi-family buildings must provide concentrated unit access points. Monotonous access balconies and corridors running the length of the exterior of a building are prohibited. F. Roof Form and Vertical Articulation 1. Roof form must comply with Section 5.5.4.F.3, Roof Form. 2. In addition to the vertical articulation requirements cited above, buildings with more than two stories and 100 feet in length along a public street, must include a variation in building stories by at least one story. Corner buildings must only be required to apply such standard to the elevation with the most linear public street frontage. G. Roofing Design and Materials 1. Roofing design and material must comply with Section 5.5.4.F.4, Roofing Design and Materials. H. Exterior Wall Materials 1. A minimum of two distinct building materials from the preferred material list must be utilized on all façades to provide architectural detail and interest. a. For purposes of this section, preferred materials must be defined as: (i) Stone or brick laid up unit by unit and set in mortar; (ii) Exterior portland cement plaster (stucco) with three coats over metal lath or wire fabric lath; (iii) Cultured stone, cast stone, or natural stone panels; (iv) Architecturally finished block (i.e. burnished block or split faced concrete masonry units), only up to 4 feet above the foundation or surrounding grade; (v) Exterior Insulation and Finish System (EIFS), but only for trim and eaves; (vi) Cementitious fiberboard siding, provided that: (1) It shall only be used on multi-family structures that are three stories or less in height; (2) Each side of a structure may contain a maximum coverage of 25 percent cementitious fiberboard siding; (3) In no instance shall an elevation parallel and visible from a public street include cementitious fiberboard; and (4) All cementitious fiberboard must be on a minimum 10-year maintenance schedule, which must include repairing missing or broken cementitious fiberboard and repainting. (vii) Metal cladding; or (viii) Other material deemed appropriate for the architectural style, as approved by the Zoning Administrator. (ix) The use of wood for trim, accents, or soffits, may be permitted if approved by the Zoning Administrator. I. Transparency and Commercial Aesthetic 1. At least 25 percent of all walls facing a public street must contain windows or doorways. 2. All ground floor walls facing a major arterial, frontage road, or highway, must contain: a. Minimum 40 percent windows or doorways; b. Minimum ceiling height of 12 feet; c. Incorporate canopies or awnings over the doorways and low-sill windows; and d. Include hardscaping elements and small plazas between the building and right-of-way. J. Architectural Features 1. The top floor of any building must contain a distinctive finish, consisting of a cornice, banding, or other architectural termination. 2. For all structures three stories or more in height, the base (first 20 feet) of a building must be distinguished from the remainder of the building by providing a minimum of three of the design elements listed above in subsection 5.12.5.B.2, above. 3. Multi-family buildings must be designed to incorporate visually heavier and more massive elements at the building base, and lighter elements above the base. Upper stories must not appear heavier or demonstrate greater mass than the lower stories of the building. K. Awnings and Overhanging Eaves 1. Awnings and overhanging eaves must be constructed of industry-accepted metal, canvas, and woven vinyl when adjacent to a public street. L. Balconies 1. Generally, all balconies must be inset and flush with the building’s façade. 2. At least 50 percent of studio apartments must include a 20 square-foot balcony. 3. Single-bedroom units must provide at least 30 square feet of balcony space. 4. All other units must provide at least 50 square feet of balcony space with a storage closet. 5. 10 percent of all residential-only ground floor units must provide a minimum 60 square-foot outdoor lawn with a four-foot wrought iron fence and gate. In no instance shall this requirement compete with Section 5.12.5.I, Transparency and Commercial Aesthetic. M. Entry Design 1. To the maximum extent practicable, the primary entrance and façade of individual buildings within a residential development shall must not be oriented towards parking, but must be oriented towards: a. An abutting public street, or b. Common open space, such as interior courtyards, parks, or on-site natural areas, or features with a clearly defined and easily accessible pedestrian circulation system. 2. Ground-floor units with frontage along the primary street must have an entrance that faces the street. Multi-family buildings located with multiple street frontages must provide entrances to units along each street frontage. a. Dwelling units above the ground floor must have interior unit entrances, except that exterior stairs are permitted for access to upper-floor units only if they are oriented towards a central plaza not visible from any street. 3. Stairwells and stairways shall be integrated into the design of the building and comply with Section 5.12.4.G above. N. Garages and Carports 1. All garages and carports must be located at the rear or side of the primary structure. Garages may be integrated into the building with the units. 2. All carports and garages must be designed as an integral part of the architecture of the project. Garages and carports shall be constructed with compatible architectural treatments that match the main buildings (e.g., roof pitch, gable type and orientation, roof materials). 3. For the end support columns of each carport structure, 75 percent of support columns height, as measured from the base, must be wrapped with compatible masonry or stone materials. 4. Gutter systems must be included along the perimeter of all carport rooflines. 5. Carports visible to a public street must screen 50% of the visible side through the use of architectural elements such as louvers, and maintain a 2-foot clearance measured vertically from the parking lot surface. 6. Any enclosed parking structure must be designed so that the only openings at street level are for auto or pedestrian circulation. The remaining street wall of the ground floor shall be wrapped by units or include façade treatments such as projections, recesses, niches, fenestration, or changes of materials or color. 7. All lighting within the carport must be shielded from public view. O. Retaining Walls 1. A retaining wall that is three feet in height or taller and that is not part of an improved drainage channel must be constructed of masonry, stained concrete, or textured concrete. P. Minimum Dwelling Unit Sizes 1. Minimum dwelling sizes must comply with Section 5.5.2.C., Multi-Family and Mixed-Use Residential Dwelling Unit Sizes. 5.12.6. OTHER DESIGN STANDARDS A. Defensible Space 1. Crime Prevention Through Environmental Design (CPTED) best practices, including providing defensible space, opportunities for natural surveillance, territorial reinforcement, and access control, should be incorporated into site, building, and unit design. 2. The concept of private space and control of access points should be reinforced using low fences and landscaping, as appropriate. 3. Window placement between units should balance privacy and natural surveillance. B. Trash and Storage Areas 1. In addition to the requirements of Section 5.3.3.E Refuse Facility Screened, the standards in this section shall apply. 2. Trash enclosures must be internalized and oriented away from streets and residential areas. Enclosures must be located inside parking areas or at the end of parking bays. Enclosures should not be located adjacent to primary buildings. 3. Trash enclosures must be placed in locations for tenant convenience and pickup service. 4. Enclosures must be architecturally compatible in design to the primary buildings on site using common colors, building materials, and roof materials. C. Mailrooms and Other Accessory Structures 1. Mailrooms, package drop-offs, and mail kiosks must be incorporated within an accessible, secured, and enclosed building. 2. Mailrooms or mail kiosks may be incorporated into another building or separated from all other buildings by a minimum of 20 feet. 3. All mailrooms or accessory structures must be architecturally compatible in design to the primary buildings on site using common colors, building materials, and roof materials. 4. In addition to these standards, all mailrooms and other accessory structures must comply with Section 5.12.4.G, above.

Amended by Ord. No. 26-019, passed 4-21-2026.

Ask a question about Arlington law

Corpus searches the Arlington sections it holds and shows the ones that match, with their citations. Free, no sign-in.