Code of the City of Arlington, Texas (City Secretary chapter PDFs as posted 2026-11-07, each current through the ordinance named on its cover, with the City Secretary's adopted-not-yet-codified Ordinances 25-063, 25-069, 25-073, 25-074, 25-075, 25-084, 26-003, 26-004, 26-019, 26-024 and 26-027 applied; Anti-Discrimination chapter not included) · Arlington City Code, Unified Development Code Chapter, § 5.6

Corpus is an independent public-information project, not the official City of Arlington website. Stable reference: corpuslaw.us/code/66258201-eb83-44c7-af20-a250989a8dc7

5.6. NON-RESIDENTIAL DESIGN STANDARDS

5.6.1. PURPOSE The intent of this section is to establish design and development standards that foster high-quality, attractive, and sustainable non-residential development. The standards are intended to: A. Protect and enhance the character and quality of commercial and industrial areas in Arlington; B. Protect and enhance the long-term market value of property within Arlington; C. Enhance the human and pedestrian scale of commercial and industrial developments and ensure compatibility between residential neighborhoods and adjacent commercial and industrial uses; D. Mitigate negative visual impacts arising from the scale, bulk, and mass of large buildings and centers; E. Promote building designs and construction practices that are sustainable and adaptable to multiple uses for extended building lifecycles; and F. Balance the community’s economic and aesthetic concerns. 5.6.2. APPLICABILITY A. The general applicability standards in Section 5.1, Applicability of this Article, shall apply to this section. B. These non-residential design standards shall apply to the following: 1. All new structures or existing structures expanded by 30 percent or more in gross square footage in all residential zoning districts and the LO, OC, NC, CC, GC, HC, BP, and FH zoning districts. 2. All new structures or existing structures expanded by 30 percent or more in gross square footage in the LI and IM zoning districts for land uses in the public and institutional and commercial uses categories, as described in Article 3, Use Standards. 3. All new structures or existing structures expanded by 30 percent or more in gross square footage for all uses in the LI and IM zoning districts located within 600 feet of the right-of-way of US 287 Highway between Interstate 20 and the southern city limits. 4. In the event of an express conflict between a building design standard in this Section 5.6 and an overlay district, the standard for the overlay district shall control, as provided in Section 2.1.5, Relationship to Overlay Districts. C. Mixed-use projects shall comply with the Section 5.6 and Section 5.7, Mixed-Use Design Standards. D. Alternate building and site designs may be approved by the Zoning Administrator through the procedure described in Section 10.4.22, Alternative Equivalent Compliance. E. All non-residential and mixed-use development in Form-Based Zoning Districts shall meet the design standards in Article 13 based on the applicability for the specific FBZD. 5.6.3. SITE DESIGN AND BUILDING ORGANIZATION A. Purpose Site design standards address a development’s relationship to its surrounding natural features and development patterns. They also address the relationship between key elements within the site. Careful site design is critical to the success of projects, and the standards of this Section should be considered at the outset, and throughout, the design process. The standards of this Section are intended to: 1. Ensure development relates to the physical characteristics of the site; 2. Ensure building scale, orientation, and design relates to the surrounding uses and streets, and creates a cohesive visual identity and an attractive street scene; 3. Ensure site design for efficient pedestrian, bicycle, transit, and vehicular circulation patterns, and create a high-quality pedestrian environment; 4. Promote design environments built to human scale; 5. Ensure delivery, trash, and loading facilities are located so as not to impede regular vehicular and pedestrian circulation and access routes; and 6. Ensure safe and efficient access between buildings and parking areas. B. Non-residential Contextual Front Setbacks 1. The front setback for infill development may be established as a range based on the locations of the primary structures on abutting lots in the same zone district located on the same street frontage as, and on each side of, the subject lot (i.e., two abutting lots set the range), as approved by the Zoning Administrator. 2. Development of a principal structure on the subject lot shall be set back no further from the primary street than the furthest front façade of the principle building on either of the two abutting lots, and shall be located no closer to the primary street than the closest front façade C. Building Organization and Orientation 1. Individual Buildings a. Development composed of one or two buildings shall be oriented so that the front façade faces the street from which the building derives its street address. b. In cases where the long axis of a building is perpendicular to the primary street, the portion of the structure facing the primary street shall be configured with at least one or more windows that are transparent. c. In cases of redevelopment where the structure is on a corner, the building may be addressed from an entrance on either street provided that addressing integrity for first responders is maintained. 2. Multi-Building Organization Development composed of three or more buildings shall be configured to: a. Break up the site into a series of smaller "blocks" defined by on-site streets, vehicle access ways, pedestrian walkways, or other circulation routes; or b. Frame the corner of an adjacent street intersection or entry point to the development; or c. Frame and enclose on at least two sides parking areas, public spaces, or other site amenities; or d. Frame and enclose outdoor dining or gathering spaces for pedestrians between buildings; or e. On sites of 15 acres or more, frame and enclose a "main street" pedestrian or vehicle access corridor within the development site. 3. Entrance Orientation [image omitted; see the official code] The principal building entrance shall face the street providing the main access to the site. In cases where the principal entrance does not face the principal street, the entrance shall be connected to the street and adjacent parking areas with sidewalks that meet the shading requirements of Section 5.6.4.J, Providing for Shade. [image omitted; see the official code] Figure 5.27 Building entry directly from a 4. Building Entry Design street a. All buildings shall have their primary entrance directly off the street or through a recessed area, courtyard, or plaza located adjacent to the street. b. The primary entryway shall be readily [image omitted; see the official code] apparent as a prominent architectural component from the street, thus creating a focal point. However, non-residential buildings with multiple tenants on the ground floor or multiple primary entrances shall have all entrances treated architecturally. c. Primary building entrances are to be defined and articulated with [image omitted; see the official code] Figure 5.28 Building entry through a architectural elements such as courtyard pediments, columns, porticos, porches, and overhangs. d. All ground-floor entrances shall be covered or inset. This requirement shall not apply to loading areas. D. Transitions in Height and Mass Transitions between non-residential structures and residential neighborhoods shall be provided by using a combination of the following techniques: 1. Concentrating the tallest buildings at the center of the site or along primary street frontages; 2. Stepping down the height of buildings along the shared lot line or street frontage to the average height of the adjacent residential structures; or 3. Providing gradual decreases in building height and mass (other than step-down, as described above) so that new structures have a comparable scale as adjacent residential structures along the shared lot line or street frontage. E. Ballfield Lighting For an exception to the maximum building height, in residential zoning districts, the Zoning Administrator may approve certain requests for alternative equivalent compliance as provided under Section 10.4.22 of this Code. 5.6.4. BUILDING DESIGN A. Purpose Building design directly influences the character and function of non-residential development. The standards of this Section are intended to: 1. Ensure that multi-building or phased commercial developments use compatible schemes of materials, colors, and architectural styles to ensure consistency; 2. Ensure that buildings are designed to a human scale; and 3. Encourage sustainable development by limiting the amount of resources necessary to construct and operate buildings and by designing buildings to be adaptable for multiple uses. B. 360-Degree Architecture All building elevations shall be architecturally finished with similar levels of materials and detailing (e.g., tiles, moldings, cornices, wainscoting, etc.). Blank walls void of architectural details or other variation are prohibited. C. Building Mass 1. Horizontal Articulation Buildings shall be designed to reduce apparent mass by dividing façades into a series of smaller components. No individual component shall have a length of more than 60 feet. Components shall be distinguished from one another through four or more of the following: a. Variations in roof form or variations in roof height of two feet or more; b. Changes in wall plane of 24 inches or more in width and depth; c. Variations in the arrangement and recessing of doors and windows; d. Recognizable changes in texture, material, or surface colors; e. Decorative columns; or f. Minimum ten-foot parapet return. 2. Vertical Articulation a. Buildings greater than two stories or taller than 20 feet shall be designed to reduce apparent mass by including a clearly identifiable base, middle, and top, with horizontal elements separating these components. b. A well-defined cornice or fascia shall be located at the top of the storefront and at the roofline. c. The component described as the middle shall constitute a minimum of 50 percent of the total building height. [image omitted; see the official code] [image omitted; see the official code] Figure 5.29 Example of horizontal articulation (left) and vertical articulation (right) 3. Other Techniques Buildings should incorporate other techniques to divide further large building façades, including the following: a. In large stores with internal functions (e.g., coffee shop, deli, florist), buildings should include a minor storefront with a separate entrance. Large uses (e.g., grocery stores, department stores, warehouse stores) should include multiple entrances. b. Architectural elements including projecting volumes, windows, balconies, loggias, canopies, pediments, and moldings that break up the mass of the building are encouraged. c. Building design should avoid oversimplified, one-dimensional façades that lack human scale. d. Design articulation should not apply evenly across the building façade, but should be grouped for greater visual impact, employing changes in volume and plane. e. Enhancement of long unadorned walls may be accomplished with: (i) Light and shade design elements, (ii) Recesses and projections, (iii) Vertical accents or focal points, (iv) Murals or sculptures, (v) Masonry texture features, or (vi) Landscaping. D. Design Elements 1. Structures 20,000 square feet or less shall include a minimum of four of the architectural design features listed below. Structures over 20,000 square feet shall include a minimum of six of the architectural design features listed below: a. Canopies, awnings, arcades, covered walkways, or porticos; b. Recesses, projections, columns, pilasters projecting from the planes, offsets, reveals, or projecting ribs used to express architectural or structural bays; c. Varied roof heights for pitched, peaked, sloped, or flat roof styles; d. Articulated cornice line; e. Arches; f. Display windows, faux windows, or decorative windows; g. Architectural details (such as tile work and molding) or accent materials integrated into the building façade; h. Integrated planters or wing walls that incorporate landscaping and sitting areas or outdoor patios; i. Integrated water features; or j. Other architectural features approved by the Zoning Administrator. 2. The dominant primary cladding material shall be used on at least 20 percent of the wall area of the side elevations of the structure. 3. All service and aesthetic attachments to buildings shall be designed to complement the buildings they serve in terms of their color and/or material. This includes such items as railings, walls, conduits, ladders, stack pipes, drain spouts, and similar items. [image omitted; see the official code] Figure 5.30 Examples of recesses and projections. E. Architectural Accent Features In addition to the design elements required by 5.6.4.D above, to add detail to a building’s façade, a minimum of three of the following accent features are required: 1. Overhang eaves, 2. Banding, 3. Pilasters, [image omitted; see the official code] 4. Articulated parapets, [image omitted; see the official code] 5. Cornices, 6. Columns, 7. String courses, 8. Projecting windows, 9. Window sills, Figure 5.31 Architectural accent feature examples. 10. Rustication, 11. Lintels, and 12. Porches. F. Roof Design 1. Roofline Articulation Variations in rooflines shall be used to add interest and reduce the scale of large buildings. Roof features shall complement the character of the overall development. [image omitted; see the official code] Figure 5.32 Examples of acceptable roof design. 2. Flat Roofs Flat roofs shall include parapets that adhere to articulation requirements for the main face of the structure. The average height of the parapet shall not exceed 15 percent of the height of the supporting wall, unless rooftop equipment cannot be sufficiently screened. A three-dimensional cornice treatment is encouraged for parapets. Parapets shall look complete from all sides if visible at any distance from the ground. Parapets shall be constructed of the same material as the primary façade. 3. Overhanging Eaves Overhanging eaves shall extend at least two feet past the supporting walls. 4. Roof Pitch Pitched roofs shall have a minimum pitch of 4:12 for all structures, unless otherwise approved by the Zoning Administrator. This requirement excludes roofs for entries and dormers. 5. Architectural Elements Architectural elements that add visual interest to the roof, such as dormers and masonry chimneys, are encouraged. 6. Roof Materials Sloped or pitched roofs constructed of asphalt shingles, synthetic shingles, standing seam metal, or tile are preferred. Flat roofs may be constructed of any industry-standard material. G. Awnings, Canopies, Arcades, and Overhangs Structural awnings are encouraged at the first-floor level to enhance articulation of the building. 1. The material of awnings and canopies shall complement the building. 2. Awnings shall not be internally illuminated. 3. Canopies shall not exceed 40 linear feet without a break. 4. Awnings shall not extend more than five feet over the public sidewalk, unless otherwise approved by the Zoning Administrator, up to a maximum of 10 feet, and are in keeping with the architectural style of the building. 5. Canopies shall respect the placement of street trees and lighting. 6. All large canopies that require structural columns for support shall be completely faced with an approved finish material measured from the finished grade to the canopy roof. Materials used on columns and canopies shall be complementary to the building. [image omitted; see the official code] Figure 5.33 Examples of building canopy and awning. H. Unified Design 1. If a building or center has a primary architectural theme, that theme should be used around the entire building. This can include, but is not limited to, the use of tile accents, stucco designs, awnings, cornice treatments, stepped parapets, trellises or arbors with live plant material, textured materials such as stone or brick, planters, or colored panels. 2. The architectural design within a multi-building development of structures (including freestanding outparcel structures) shall be organized around a consistent architectural theme in terms of the character, materials, texture, color, and scale of buildings. Themed restaurants, retail chains, and other franchise-style structures shall adjust their standard architectural model to be consistent with a development's architectural character. 3. All buildings in a single development, whether developed at a single time or in phases, shall share at least four architectural features in order to create continuity within the overall development. These features include, but are not limited to, the following: a. Overhangs, b. Canopies or porticos, c. Recesses or projections, d. Arcades, e. Raised corniced parapets over the entrance, f. Roof style and materials, g. Arches, h. Outdoor patios, i. Tower elements (at strategic locations), j. Display windows, k. Integral planters that incorporate landscaped areas or seating areas, l. Water features, and m. Public art or sculptures. [image omitted; see the official code] Figure 5.34 Visual continuity between buildings. I. Building Materials and Colors 1. Wall Materials a. No single building material shall [image omitted; see the official code] cover more than 80 percent of the front building façade. b. Preferred materials shall be defined as: (i) Native stone, brick, or tile laid up unit by unit and set in mortar; (ii) Stucco (exterior portland cement plaster with three coats over metal lath or wire fabric lath); [image omitted; see the official code] Figure 5.35 No single material covering (iii) Cultured stone or cast stone; more than 80% of front façade (iv) Architecturally finished block (i.e. burnished block, split faced concrete masonry units, or architecturally finished tiltwall); (v) Architecturally finished pre-cast wall that is profiled, sculptured, or provides three-dimensional interest; (vi) Poured-in-place concrete wall; (vii) Composite aluminum cladding such as Alucobond; (viii) Exterior Insulation and Finish System (EIFS) located at least four feet above grade and not more than 20% of the façade; and (ix) Architectural glass of less than 25 percent reflectance. [image omitted; see the official code] Figure 5.36 Architectural materials. c. The rear façade of a building that is adjacent to an industrial use may be constructed with tiltwall concrete, concrete block, or aggregate concrete in addition to the materials permitted in this subsection 5.6.4.I. d. Structures 20,000 square feet or less shall [image omitted; see the official code] require a minimum of two distinct building materials from the approved material list be utilized on all façades to provide architectural detail and interest. e. Structures over 20,000 square feet shall require a minimum of three distinct building materials from the approved material list be utilized on all façades to provide architectural detail and interest. Figure 5.37 Example of façade design. f. Unless exempted or permitted by planned development ordinance or alternative equivalent compliance, the front façade of any building utilizing more than 20 percent (non-architectural) metal shall be screened from view by structures or landscaping comprised of evergreen trees, layered in two rows at a rate of not less than one tree per 300 square feet, with a minimum three-inch caliper and 10 feet in height at the time of installation. 2. Awnings and Overhanging Eaves Awnings and overhanging eaves may be constructed of industry-accepted metal, canvas, and woven vinyl. 3. Façade Colors Façade colors shall be low reflectance, subtle, neutral, or earth tone colors. The use of metallic colors, black, or fluorescent colors is prohibited. J. Providing for Shade 1. All development shall provide shaded internal pedestrian walkways along at least 50 percent of all building façades adjacent to or facing streets, outdoor gathering spaces, or parking areas. 2. On sites of 15 acres or more developed or redeveloped as a single project, shaded sidewalks between structures shall constitute a minimum of 30 percent of the sidewalks within sites containing multiple buildings. 3. Buildings should be oriented to minimize direct solar exposure on the primary building façade and areas of high pedestrian activity. K. Transparency and Glazing 1. At least 25 percent of all walls facing a public street shall contain windows or doorways. 2. Windows shall not be installed from sidewalk grade to 24 inches high, unless approved by the Zoning Administrator. Divided-light windows are encouraged. 3. Lighting that outlines and/or details a window shall be prohibited. This includes the use of light tubing, such as neon or LED, and flashing or running lights. L. Gateways Buildings located at entrances to a development demarcate a gateway that will create an overall identity, set the tone for the development, and mark arrival or entry. 1. Structures at major entry points of a [image omitted; see the official code] development with three or more structures shall be organized along the street and at the intersection to create a gateway. 2. Architectural attachments shall be incorporated into the façades of buildings, and be placed at major entry points, to help emphasize arrival or entry into the [image omitted; see the official code] development. These features may include, Figure 5.38 Appropriate gateway but are not limited to: building. a. Eaves, b. Planters, c. Mounted signs (where they do not conflict with the Federal and Texas Highway Beautification Acts), d. Pilasters, e. Tower elements, f. Water features, or g. Arcades. M. Construction of Building Elements Spanning Public Right-of-Way A specific use permit may be requested for an enclosed building element that spans a public right-of-way provided: 1. The structure is intended for connecting buildings to convey people or materials across a public street, 2. No structural supports are located in rights-of-way, and 3. An agreement is executed with the City prior to permitting for the use of right-of-way. N. Retaining Walls A retaining wall that is three feet in height or taller and that is not part of an improved drainage channel shall be constructed of masonry, stained concrete, or textured concrete. O. Special Design Requirements in Certain Zoning Districts In the FH district, service bays and/or loading areas shall not face a public street or be located in the front of an FH development.

Amended by Ord. No. 26-019, passed 4-21-2026.

Ask a question about Arlington law

Corpus searches the Arlington sections it holds and shows the ones that match, with their citations. Free, no sign-in.