For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 5.4 — Off-Street Parking and Loading

Code of the City of Arlington, Texas (City Secretary chapter PDFs as posted 2026-11-07, each current through the ordinance named on its cover, with the City Secretary's adopted-not-yet-codified Ordinances 25-063, 25-069, 25-073, 25-074, 25-075, 25-084, 26-003, 26-004, 26-019, 26-024 and 26-027 applied; Anti-Discrimination chapter not included) · Arlington City Code, Unified Development Code Chapter, § 5.4

Corpus is an independent public-information project, not the official City of Arlington website. Stable reference: corpuslaw.us/code/e210adfc-3ea7-4962-9346-ff3ade14e769

5.4. OFF-STREET PARKING AND LOADING

5.4.1. PURPOSE The regulations of this section are intended to ensure provision of off-street parking and loading facilities in rough proportion to the generalized parking, loading, and transportation demands of different land uses. By requiring such facilities, it is the intent of this section to help avoid the negative effects associated with spillover parking into adjacent neighborhoods, while at the same time avoiding the negative environmental and urban design effects that can result from parking lots and other vehicular use areas. The provisions of this section are also intended to help protect the public health, safety, and general welfare by: A. Helping avoid and mitigate traffic congestion; B. Encouraging multi-modal transportation options and enhanced pedestrian safety; C. Providing methods to help reduce stormwater runoff and the heat island effect of large paved parking areas; and D. Providing flexible methods of responding to the transportation and access demands of various land uses in different areas of the city. 5.4.2. APPLICABILITY A. Generally The off-street parking and loading standards of this section shall apply to all parking lots and parking structures accessory to any building constructed and to any use established in every district. Except when specifically exempted, the requirements of this section shall apply to all temporary parking lots and parking lots that are the principal use on a site. B. Expansions and Enlargements The off-street parking and loading standards of this section shall apply when an existing structure or use is expanded or enlarged. Additional off-street parking and loading spaces shall be required to serve the enlarged or expanded area, provided that in all cases the number of off-street parking and loading spaces provided for the entire use (pre-existing plus expansion) shall equal 100 percent of the minimum ratio established in Tables 5.4-1 and 5.4-2. C. Change in Permitted Uses A permitted use that does not meet the parking requirements of this section may be converted to another permitted use without full compliance with the required number of parking spaces if the Zoning Administrator determines: 1. The maximum amount of parking spaces possible is provided without removing or partially removing a structure. 2. If a structure or a portion of a structure is voluntarily removed, the resulting area shall be used to provide the additional parking spaces necessary towards fulfilling the requirements of Tables 5.4-1 and 5.4-2. 3. The amount of parking available at least 80 percent of the parking required for the new use in Tables 5.4-1 and 5.4-2. D. Location Required off-street parking, loading, and vehicle stacking spaces shall be located on the same lot as the principal use, except as otherwise provided in this section. E. Use Limited to Parking No required off-street parking facility or loading space shall be used for sales, non-vehicular or rental vehicle storage, repair, or service activities unless specifically provided for in this Code. 5.4.3. OFF-STREET PARKING STANDARDS A. Off-Street Parking Schedule A The off-street parking requirements for uses allowed by this Code are listed in Table 5.4-1. The vehicle stacking requirements of Section 5.4.6, Drive-Through Vehicle Stacking and Noise Reduction Standards, may also be applicable to certain uses. | TABLE 5.4-1: Off-Street Parking Schedule A USE CATEGORY | USE TYPE | PARKING REQUIREMENT RESIDENTIAL USES Household Living | Dwelling, duplex 2 per dwelling unit 1.5 dwelling unit (work area calculated as retail, office, or commercial Dwelling, live/work use) Dwelling, multi-family 1 per studio | 1.5 per 1 bedroom | 2.0 per 2 bedroom | 2.5 per 3 within RMF-22 Zoning District bedroom | 2.5 + .5 for each bedroom more than 3 Dwelling, multi-family or Mixed- Primary use: 1 parking space per dwelling unit. Use within Non-Residential Accessory Parking: 5 parking spaces (Office Staff) plus 1 space per Zoning Districts 10,000 square feet of gross residential floor area (Visitor Parking). Dwelling, single-family detached 2 per dwelling unit Dwelling, SF attached or 1 parking space per unit for lots less than 4,000 SF detached (within small-lot 1 garage, plus 1 driveway space for lots between 4,000 to 5,000 SF developments) size. Dwelling, townhouse 2 per dwelling unit Garage apartment 1 per dwelling unit HUD-Code manufactured home 2 per dwelling unit | Mobile home Group Living | Assisted living facility 2.0 per dwelling unit, not to exceed 1 per bedroom (≤6 residents) Assisted living facility 1.0 per dwelling unit (≥7 residents) Boarding home facility As required for the principal use; not to exceed 1 per bedroom Community home for disabled As required for the principal use; not to exceed 1 per bedroom persons Foster family home As required for the principal use Foster group home As required for the principal use plus 1 per 2 residential beds Halfway house 1 per bed plus 1 per 100 sf of common area | TABLE 5.4-1: Off-Street Parking Schedule A USE CATEGORY | USE TYPE | PARKING REQUIREMENT | Independent senior living 1.3 per dwelling unit facility Lodging house |fraternity or 1 per bed sorority house | private dorm Nursing home 1.0 per 4 beds PUBLIC AND INSTITUTIONAL USES Community and Cultural Facilities | Art gallery or museum 1 per 1,000 sf GFA Correctional facility Schedule C Domestic violence shelter 3 per 1,000 sf GFA Emergency shelter 3 per 1,000 sf GFA Government administration and 3 per 1,000 sf GFA civic buildings Mortuary, crematory, or funeral 3 per 1,000 sf GFA chapel Philanthropic institution (other 3 per 1,000 sf GFA than listed) 1 space per 4 seats. If no fixed seating, then based on 25% maximum Religious assembly capacity of the assembly areas, as determined by the International Building Code. Educational Facilities | Business school 3 per 1,000 sf GFA Elementary Schools: 2 per classroom Middle Schools: 2 per classroom Public or private school High Schools: 6 per classroom and 1 per 300 sf of administrative office space Trade school 3 per 1,000 sf GFA University, college, or seminary Schedule C Health Care Facilities | 1 per 4 beds based on maximum capacity, plus 3 per 1,000 sf GFA of Hospital office area, plus parking as required for accessory uses 1 per 4 beds based on maximum capacity, plus 3 per 1,000 sf GFA of Hospital, psychiatric office area, plus parking as required for accessory uses Medical or dental office or clinic 4 per 1,000 sf GFA Parks and Open Space | Cemetery Schedule C Community garden 1 per 5,000 sf of lot area Schedule C. Playfields (soccer, baseball, etc.) shall have minimum of Public park or playground 20 spaces per field. COMMERCIAL USES Agriculture | Animal production None Crop production None Animal-related Services | Kennel, commercial 1 per 1,000 sf GFA Stables, commercial 1 per 5 stalls Veterinary clinic 2 per 1,000 sf GFA | Auto service center 2 per 1,000 sf GFA | TABLE 5.4-1: Off-Street Parking Schedule A USE CATEGORY | USE TYPE | PARKING REQUIREMENT Auto Sales, Equipment, and Repair | Auto repair garage, major 2 per 1,000 sf GFA Car wash 2 spaces plus any stacking spaces required. See Section 5.4.6 Gasoline sales 2 spaces plus any stacking spaces required. See Section 5.4.6 Motor vehicle rental 2.5 per 1,000 sf GFA Motor vehicle sales, new 2 per 1,000 sf GFA of sales floor area Motor vehicle sales, used 2 per 1,000 sf GFA of sales floor area Parking garage None Financial Services | All uses 2.5 per 1,000 sf GFA Food and Beverage Services | Bar 14 per 1,000 sf GFA Catering service 3 per 1,000 sf GFA Restaurant 10 per 1,000 sf GFA, including outside dining/drinking areas. Restaurant, take-out and 3 per 1,000 sf GFA delivery only 10 per 1,000 sf GFA, plus any stacking spaces required. see Section Restaurant with drive-through 5.4.6 Sidewalk cafe Same as restaurant Lodging Facilities | Bed & breakfast inn 1 per guest room, in addition to those required for principal residence 1 per guest room or residence unit up to 100 units, then 0.75 per unit Hotel, all types over 100. 50% of spaces may be counted to satisfy parking requirements of accessory uses Overnight parking facility Schedule C Office, Business or Professional | All uses 2.5 per 1,000 sf GFA Telemarketing call center 8 per 1,000 sf of area devoted to telemarketing work stations Personal Services | Bail bond service 3 per 1,000 sf GFA Day care center 2.5 per 1,000 sf GFA General personal services (other 3 per 1,000 sf GFA than listed) Massage therapy clinic 3 per 1,000 sf GFA Tattoo parlor or piercing studio 3 per 1,000 sf GFA Recreation and Entertain- ment, Indoor | Banquet hall 10 per 1,000 sf GFA Bingo parlor 10 per 1,000 sf GFA Billiard parlor 10 per 1,000 sf GFA Bowling alley 4 per lane Gun range (indoor) 2 per target area Nightclub 14 per 1,000 sf GFA Private club, lodge or fraternal 3 per 1,000 sf GFA organization Recreation, indoor (other than Schedule C listed) Skating rink Schedule C Teen club 4 per 1,000 sf GFA | TABLE 5.4-1: Off-Street Parking Schedule A USE CATEGORY | USE TYPE | PARKING REQUIREMENT | Theatre, indoor 1 per four seats Wedding chapel 1 per four seats Recreation and Entertainment, Outdoor Retail (Sales) | Country club 4 per 1,000 sf GFA Golf course 4 per green Gun club, skeet, or target range 2 per target area (outdoor) Major tourist attraction Schedule C Recreation, general outdoor Schedule C (other than listed) Marina 0.75 spaces per boat slip, plus parking as required for other uses Boat and accessory sales, rental 2 per 1,000 sf GFA of sales floor area and service Building and landscape Schedule B materials and lumber sales Farmer’s market Schedule C General retail store, other than 3 per 1,000 sf GFA listed Firearm sales 3 per 1,000 sf GFA Nursery garden shop or plant Schedule B sales Open air vending Schedule C Package liquor store 3 per 1,000 sf GFA Pawn shop 3 per 1,000 sf GFA Secondhand goods store 3 per 1,000 sf GFA Specialty paraphernalia sales 3 per 1,000 sf GFA Swimming pool, spa and 3 per 1,000 sf GFA accessory sales and service Sexually Oriented Business | All uses 14 per 1,000 sf GFA INDUSTRIAL USES Industrial Service | Building maintenance sales and Schedule B service Cleaners, commercial Schedule B Food processing Schedule B Medical or scientific research Schedule B laboratory Heavy machinery rental, sales Schedule B and service Wrecker service Schedule B Manufacturing | Asphalt or concrete batch plant Schedule C Custom and craft work 2 per 1,000 sf GFA Gas well Schedule C | TABLE 5.4-1: Off-Street Parking Schedule A USE CATEGORY | USE TYPE | PARKING REQUIREMENT | High-impact use Schedule C Manufacturing and Assembly, Schedule B small-scale Manufacturing, light Schedule B Manufacturing, heavy Schedule B Salvage yard (indoor) Schedule C Salvage yard (outdoor) Schedule C Transportation - Related Uses | | Airport or landing field | | 2.5 space per 1,000 sf GFA of passenger terminal area | Heliport | | Schedule C | Railroad yard, shop, or | | Schedule C roundhouse | Transit passenger terminal | | 5 space per 1,000 sf GFA Utilities | | Electric generating plant | | Schedule C | Electric utility substation | | None | Radio or TV studio | | 3 per 1,000 sf GFA | Utility lines, towers or metering | | None station | Utility installation other than | | None listed Telecommunication Facilities Building-mounted antennae and None towers Telecommunication Facilities Towers ≤75 ft 1 space Stealth towers ≤100 ft Telecommunication Facilities Towers >75 ft 1 space Stealth towers >100 ft Wholesale Distribution and Storage | Cold storage plant Schedule B Contractors plant, shop and/or Schedule B storage yards Distribution center or Schedule B warehouse Self-storage facility 1 per 20 storage units, plus 2.5 per 1,000 sf GFA of office area Outside storage Schedule C Wholesale supply business Schedule B B. Off-Street Parking Schedule B Uses that reference Schedule B in Table 5.4-1, Off-Street Parking Schedule A, shall provide the minimum number of spaces identified in the table below. TABLE 5.4-2: Off-Street Parking Schedule B | Use or Activity | Required Number of Spaces Office or administrative area | | 2 per 1,000 square feet GFA Indoor sales area | | 3 per 1,000 square feet GFA Indoor storage, warehousing, | 1-3,000 square feet of floor area | 3 per 1,000 square feet GFA assembly, vehicular service, or | 3,001-5,000 square feet of floor area | 2 per 1,000 square feet GFA manufacturing area: | 5,001-10,000 square feet of floor area | 1.25 per 1,000 square feet GFA | 10,001 or more square feet of floor area | 0.8 per 1,000 square feet GFA Outdoor sales, display, or storage area (3,000 square feet or less) | 1.25 per 1,000 square feet GFA Outdoor sales, display, or storage area (more than 3,000 square feet) | 1 per 1,000 square feet GFA NOTE: The total number of required spaces is cumulative based on the variety of different functions present in a single use. [image omitted; see the official code] [image omitted; see the official code] C. Off-Street Parking Schedule C Uses that reference Schedule C in Table 5.4-1, Off-Street Parking Schedule A, have widely varying parking characteristics that make it difficult to establish a single standard. Upon receiving an application for a use subject to Schedule C standards, the Zoning Administrator shall apply the off-street parking standard specified for the listed use that is deemed most similar to the proposed use. The Zoning Administrator may also establish off-street parking requirements based on a parking analysis prepared by the applicant. Such analysis shall include estimates of parking demand based on recommendations of the Institute of Transportation Engineers, or other acceptable estimates, and shall include other reliable data collected from uses or combinations of uses that are the same as or comparable with the proposed use. Comparability shall be determined by density, scale, bulk, area, type of activity, and location. The analysis shall document the source of data used to develop the recommendations. 5.4.4. COMPUTATION OF PARKING AND LOADING REQUIREMENTS A. Fractions When measurements of the number of required spaces result in a fractional number, any fraction exceeding 0.5 shall be rounded up to the next higher whole number. B. Multiple Uses Lots containing more than one use shall provide parking and loading in an amount equal to the total of the requirements for all uses. No off-street parking space provided for one type of use or building shall be included in calculation of the off-street parking requirements for any other use or building except as prescribed in Section 5.4.7, Parking Alternatives, of this Code. C. Area Measurements Unless otherwise specified, all square footage-based parking and loading standards shall be computed based on gross floor area of the use in question. Structured parking within a building shall not be counted in such measurement. D. Off-Street Loading and Service Areas Required off-street loading spaces shall not be counted as off-street parking spaces in computation of required off-street parking space. Parking spaces located in buildings used for repair garages or car washes, and spaces in drive-through lanes shall not be counted as meeting the required parking. E. Parking Based on Occupants Except as provided for in this section, when the standards use the number of occupants as a unit of measurement, all calculations shall be based on the occupant load as determined by the International Building Code. F. Parking Based on Seating When the standards use seating as a unit of measurement, all calculations shall be based on the occupant load of the areas used for seating as determined by the International Building Code. G. Parking for Unlisted Uses Parking requirements for uses not specifically listed in Table 5.4-1, Off-Street Parking Schedule A, shall be determined by the Zoning Administrator based on the requirements for the closest comparable use, as well as on the particular parking demand and trip generation characteristics of the proposed use. The Zoning Administrator may alternately require the submittal of a parking demand analysis that justifies estimates of parking demand based on the recommendations of the Institute of Transportation Engineers, and includes relevant data collected from uses or combinations of uses that are the same or comparable to the proposed use in terms of density, scale, bulk, area, type of activity, and location. H. Special Parking Requirements in Certain Zoning Districts 1. NMU and RMU Districts a. In the mixed-use districts, the total requirement for off-street parking facilities shall be the sum of the requirements for the various uses computed separately. b. The total number of required parking spaces in a mixed-use district may be reduced by the Zoning Administrator if the applicant prepares a parking evaluation that demonstrates a reduction is appropriate based on the expected parking needs of the development, availability of mass transit, and similar factors. The parking evaluation shall be prepared in a form and manner prescribed by the Zoning Administrator. c. Surface parking lots, off-street parking spaces, and associated driving aisles shall not be permitted between the building and street. However, the Zoning Administrator may approve an off-street area for passenger drop-off or pick-up activity. 2. Form-Based Zoning Districts and the LCMUO a. Off-street parking for all uses in Form-Based Zoning Districts, including DT-FBZD, shall follow standards in Article 13 in lieu of Table 5.4-1, Off-Street Parking Schedule A. b. For non-residential or mixed-use development within the LCMUO district boundary, the off-street parking requirements of Table 5.4-1, Off-Street Parking Schedule A, shall be reduced to one-half the amount required in other zone districts. However, for developments utilizing Texas Local Government Code Chapter 218, where the parking requirements are already reduced, no further reduction shall be provided. c. For non-residential or mixed-use development where there is on-street parking immediately in front of any lot or parcel in the LCMUO district, the off-street parking requirement under subsections a. or b. above may be reduced by one space for each on-street space located adjacent to the lot and between the side lot lines of the lot. For all development within FBZDs, the off-street parking requirements may be reduced in accordance with Article 13. d. All surface parking lots shall be located behind and/or on the sides of buildings. Side parking shall be limited to 25 percent of the width of the street frontage. Surface parking lots, off-street parking spaces, and associated driving aisles shall not be permitted between the building and street. However, the Zoning Administrator may approve an off-street area for passenger drop-off or pick-up activity. All development in FBZDs shall meet the parking configurations standards in Article 13. 3. EDO Overlay District a. Uses in the EDO overlay district are not permitted to exceed the parking requirement established in Table 5.4-1, Off-Street Parking Schedule A, unless approved by the Zoning Administrator. b. Parking lots or parking structures shall not be located or constructed within the front building setback area. However, properties fronting on Interstate 30 along Ryan Plaza Drive, East Copeland Road, or Wet ‘n Wild Way; or fronting on SH 360 along Watson Road, may have one row of parking within the setback if approved by the Zoning Administrator. 4. FH District a. No more than one double-loaded parking aisle shall be permitted in front of an FH development facing public right-of-way. No parking is allowed in the front of a multi-family residential building and street. 5.4.5. ACCESSIBLE PARKING In addition to the required off-street parking identified in Section 5.4.3, Off-Street Parking Standards, accessible parking spaces are required for each parking facility on a site, such as lots and garages. Requirements apply equally to public, private, employee, and/or restricted parking. On sites with multiple parking facilities, the minimum number of accessible spaces must be calculated separately for each parking facility instead of on the combined total of parking spaces provided on the site. The required number of accessible spaces, including van spaces, is calculated separately for each parking lot and site. All accessible parking must be in compliance with the Americans with Disabilities Act (https://www.ada.gov/topics/parking/) and the Texas Accessibility Standards (https://www.tdlr.texas.gov/ab/abtas.htm). 5.4.6. DRIVE-THROUGH VEHICLE STACKING AND NOISE REDUCTION STANDARDS The following standards shall apply to businesses that contain a drive-through establishment, regardless if the drive-through is part of another use (e.g., restaurant or financial institution) or if it is a stand-alone use (e.g., automatic teller machine). A. Location of Stacking Lanes and Use of Audible Electronic Devices 1. Stacking lanes shall not be located between the building and the street rights-of-way. 2. Audible electronic devices such as loudspeakers, automobile service order devices, and similar instruments shall not be audible beyond the property line of the site. 3. No service shall be rendered, deliveries made, or sales conducted within the required front yard or corner side yard; customers served in vehicles shall be parked to the sides and/or rear of the principal building. 4. All drive-through areas, including but not limited to menu boards, stacking lanes, trash receptacles, loudspeakers, drive up windows, and other objects associated with the drive-through area shall be located in the side or rear yard of a property to the maximum extent feasible, and shall not cross, interfere with, or impede any public right-of-way. B. Stacking Space and Lane Requirements The number of required stacking spaces shall be as provided for in Table 5.4-3, Stacking Space Requirements. TABLE 5.4-3: Stacking Space Requirements Activity | Minimum Stacking Spaces (per lane) | Measured From: Bank, Financial Institution, or Automated Teller Machine (ATM) | 3 | Teller or Window Restaurant | 6 | Pick-Up Window Full Service or Automated Vehicle Washing Establishment | 6 | Outside of Washing Bay Fuel or Gasoline Pump Island | 2 | Pump Island Other | As determined by the Zoning Administrator [image omitted; see the official code] [image omitted; see the official code] [image omitted; see the official code] Figure 5.7 Location of stacking spaces and lanes. Note that the stacking lanes are oriented toward the side and rear yards. C. Design and Dimensions Stacking lanes shall be provided for any use having a drive-through establishment and shall apply comply with the following standards: 1. Drive-through stacking lanes shall have a minimum width of ten feet. 2. When stacking lanes are separated from other stacking lanes, bypass lanes, or from other site areas, the separation shall be by means of a five-foot wide landscaped median or island. 5.4.7. PARKING ALTERNATIVES The Zoning Administrator may approve alternatives to providing the number of off-street parking spaces required by Section 5.4.3, Off-Street Parking Standards, in accordance with the following standards. A. Off-Premise Parking The Zoning Administrator may permit an off-premise parking facility to accommodate either required or additional parking subject to the following conditions: 1. The off-premise parking facility shall be located within 600 feet from an entrance, as measured along the shortest practical walking route, to the structure for which it will be used. 2. Off-premise parking should be connected to the use by a sidewalk or surfaced path. 3. Residential parking or accessible parking may not be provided in off-premise facilities. 4. Off-premise parking shall have the same or more intensive zoning classification as the primary use served. B. Credit for On-Street Parking The Zoning Administrator may give credit for on-street parking spaces located on the street adjacent to the entry of the building in which the use is located. Credit may not be given for parking spaces located in a residential zoning district. C. Shared Parking The Zoning Administrator may approve shared parking facilities for developments or uses with different operating hours or different peak business periods if the shared parking complies with all of the following standards. 1. Location Shared parking spaces shall be located within 600 feet of a public entrance to the uses served unless remote parking shuttle bus service is provided. 2. Zoning Classification Shared parking areas require the same or a more intensive zoning classification than required for the use served. 3. Shared Parking Analysis Where shared parking is contemplated, the applicant may be required to include parking accumulation analyses as a part of the request for approval. The analysis shall include the parking demand for each hour over a 12- to 24-hour period for a typical high volume day. This will determine the minimum number of spaces that shall be provided. Based on the analysis submitted, if the maximum number of vehicles accumulated during a peak hour or hours for all overlapping uses exceeds the number of spaces that are required to be provided, shared parking shall be limited. A prorated number of shared parking spaces may be permitted based on the justification information of the analysis. 4. Agreement for Shared Parking A shared parking plan will be enforced through a written agreement among all owners of record. An attested copy of the agreement between the owners of record shall be submitted to the Zoning Administrator for review and approval. The applicant shall record the agreement prior to the issuance of a building permit or certificate of occupancy for any use to be served by the shared parking. A shared parking agreement may be terminated if all required off-street parking spaces will be provided in accordance with the requirements of Section 5.4.3, Off-Street Parking Standards. a. Shared parking agreements that existed prior to the adoption of this Code shall continue in force. b. Amendments to pre-existing agreements shall be made pursuant to the terms of this Code and shall be done by written agreement. D. Structured Parking 1. Credit for Nearby Public Structured Parking Spaces available in public parking structures located within 1,000 feet of the subject use may be counted toward the total amount of required off-street parking if the Zoning Administrator determines that the spaces are reasonably available for the use. E. Additional Reductions in Parking The Zoning Administrator may allow an additional reduction in the required number of parking spaces (less than what is determined using the adjusted off-street parking calculation). A parking demand analysis, prepared in accordance with the Zoning Administrator’s guidelines by a qualified parking or traffic consultant, substantiating the basis for granting a reduced number of spaces is required. 5.4.8. DEFERRED PARKING The Zoning Administrator may approve a request to defer the construction of up to 20 percent of the required number of parking spaces specified in Section 5.4.3, Off-Street Parking Standards, if the request complies with the following standards: A. Reserve Parking Plan The request is accompanied by a reserve parking plan identifying: 1. The amount of off-street parking being deferred; and 2. The location of the area to be reserved for future parking, if needed. B. Parking Demand Analysis No later than 12 months after the initial certificate of occupancy is issued for the proposed development, the applicant shall submit a parking demand analysis to the Zoning Administrator that demonstrates the parking demand for the development and the adequacy of existing parking spaces. If the analysis indicates that the existing parking is adequate, then the construction of the remaining number of parking spaces shall not be required. If the analysis indicates additional parking is required, it shall be provided consistent with the reserve parking plan and the standards of this section. An applicant may request one six-month extension on the submission of a parking demand analysis. Failure to submit a parking demand analysis shall result in the revocation of the deferred parking request. C. Limitations on Reserve Areas Areas reserved for future parking shall be brought to the finished grade and shall not be used for buildings, storage, loading, or other purposes. D. Landscape Required If the Zoning Administrator determines that a reserved parking area will not be needed for parking purposes, the area shall be landscaped in compliance with all relevant landscape standards of this Code. 5.4.9. PARKING FACILITY LOCATION AND DESIGN A. Parking Space Dimensions 1. No parking space shall be less than 18 feet in length and nine feet in width, except as provided below. 2. Parking spaces may be reduced in length when a tire-stop curb is installed 16 feet from the maneuvering lane and a clear space of two feet is provided for a vehicle to overhang. The overhang is not permitted over public property, sidewalks, or a setback in which parking is not permitted. Such reduction is permitted only when the width of the maneuvering lane is maintained at 26 feet. 3. A maximum of 20 percent of the required parking spaces may be designed and reserved for compact cars. Compact car parking spaces will be a minimum of eight feet by 16 feet and shall be clearly identified with either a sign or pavement marking limiting the spaces to compact cars. The minimum parking aisle width is 24 feet. B. Location and Design of Parking Spaces The following shall apply in all zoning districts except FBZDs. 1. Parking Prohibited in Rights-of-Way and Drive Lanes a. No off-street parking facility shall be located, in whole or in part, in a public street or sidewalk, parkway, alley, or other public right-of-way. b. No off-street parking or loading space shall be located, either in whole or in part, within any fire lane required by ordinance of the City or within aisles, driveways, or maneuvering areas necessary to provide reasonable access to any parking space. 2. Garage Standards for Single-Family and Two-Family Residential Dwellings a. An enclosed two-car garage is required for all single-family detached, townhouse, and duplex dwellings. The garage must be a minimum of 390 square feet in area. b. A garage is not required for dwellings constructed prior to January 31, 1984. c. A garage may not be converted to living space unless another two-car garage is constructed on the same lot. However, garage conversions are permitted for dwellings constructed prior to January 31, 1984, provided that a driveway of at least 20 feet in length, as measured from the front property line, is constructed to accommodate the same number of vehicles as the garage. d. Tandem parking is permitted only for residential townhouses with a single-car garage, provided that the driveway accessing the garage has a minimum length of 20 feet as measured from the front property line. 3. Maintenance Parking facilities and loading berths shall be maintained and kept in a state of good repair at all times by the owner or the person in control of the premises. 4. Parking Calculations for Multi-Family Residential and Independent Senior Living Both garage parking and tandem parking space (clear minimum 18 feet in length) behind the garage may be included in the parking calculation for multi-family and independent senior living developments. C. Parking Area Location and Layout in Non-residential Districts The following shall apply in the non-residential zoning districts including FBZDs. 1. Parking Location Developments shall situate [image omitted; see the official code] buildings at the street frontage, locating parking to the side and rear of buildings to avoid views of large, paved parking areas from public rights-of-way. However, the Zoning Administrator may waive this requirement based on the prevailing development patterns in order to be consistent with the established pattern of the street and keeping with the context of surrounding structures. 2. Parking Area Layout Surface parking areas shall be divided into sub-areas, each accommodating no more than 250 vehicles. Each parking sub-area shall be separated by a minimum 15-foot wide landscaped feature, which shall Figure 5.9 Parking area layout divided into sub-areas. include pedestrian walkways and shade features such as trees or arbors. This technique shall be used to minimize the “sea of parking” between the building and the principal street and to require that the majority of off-street parking be located to the side or rear of the buildings served. Surface parking lots shall comply with the requirements in Section 5.2.2.E, Parking Lot Landscaping and Screening. 3. Circulation Area Design Circulation areas shall be designed to facilitate the safe movement of vehicles without posing a danger to pedestrians or impeding the function of the parking area. Parking lots shall maintain safe circulation patterns and access to public streets. D. Parking Location and Treatment for Mixed-Use Development The following shall apply to mixed-use developments constructed in districts where this type of development is permitted. Mixed use development in FBZDs shall meet the standards in Article 13. 1. All off-street parking shall be accessed through alleys or private access easements along the rear or side property lines. 2. All garages shall be located at the rear the structure and as part of the primary structure. Garages may not be visible from a public street. 3. All covered parking and garages shall be of the same building and roofing materials as the primary structure. [image omitted; see the official code] 4. No surface parking lots shall be located between the building and any public street. 5. Surface parking may be located behind or to the side(s) of the building, not adjacent to a public street. Figure 5.10 Appropriate location for surface parking. 6. Surface parking areas on the side may not exceed 25 percent of the total street frontage for that side. Parking areas shall not be located in front of a maximum setback line. 7. If permitted, head-in and/or parallel parking spaces may be counted toward the required parking (not to be construed as designated or reserved for the benefit of a specific person, entity or use) if immediately adjacent to lease, rental or owned property. 8. Any enclosed parking structure shall be designed so that the only openings at street level are for auto or pedestrian circulation. The remaining street wall of the ground floor shall include façade treatments such as projections, recesses, niches, fenestration, or changes of materials or color. Structured parking shall also be designed in compliance with Section 5.4.I, Parking Structures. E. Access in the DT-FBZD Where there is a useable alley, public or private, other access drives shall not be permitted. The Zoning Administrator shall determine the accessibility of an alley. F. Lighting 1. Parking lots shall have exterior lighting in all publicly accessible areas. All parking lot lighting shall be cut off lighting fixtures and be placed on a house meter. 2. Light sources must be indirect, diffused, or covered by shielded type fixtures, and be installed to reduce glare and interference with adjacent properties or streets. 3. Parking lot lighting fixtures must be attached to buildings or mounted on metal poles. Any fixture located within 100 feet of a property zoned or used for residential purposes shall not exceed 20 feet in height. G. Striping For all multi-family and non-residential uses, parking spaces shall be striped or otherwise clearly designated on the parking facility surface. H. Materials 1. All permanent parking areas and loading berths, whether required or provided in addition to the requirements of this section, shall have an all-weather surface, and shall be connected by an all-weather surfaced driveway to a street or alley. 2. An all-weather surface parking facility shall be constructed of asphalt or concrete. The Zoning Administrator may approve the use of a porous paving system or other pervious surface. I. Parking Structures The off-street parking required by this section may be located in a parking structure, whether on the same or on a different lot than the uses which it serves. Such structure shall be subject to the following: 1. Wrapping of Parking Structure Where feasible, the ground floor of parking structures in mixed-use or non-residential districts shall be wrapped with uses from the commercial, office, institutional, public, or civic categories of Section 3.1.5, Table of Allowed Uses. Parking structures with ground floors that are not wrapped with active public uses on the sides facing a public street or open to public view shall not: a. Abut street intersections or public/civic use areas, b. Be adjacent to public squares, or c. Occupy sites that are the terminus of a street vista. [image omitted; see the official code] Figure 5.11 Parking structure wrapped by space for other uses. 2. Design a. Parking structures shall be constructed of materials of similar quality, shall be compatible in appearance with adjacent buildings, and shall contain lighting sufficient for security purposes. b. Ground floor façades of parking structures not occupied by active uses shall be articulated using three or more of the following architectural features. (i) Windows or window-shaped openings with decorative mesh or similar features as approved by the Zoning Administrator; (ii) Masonry columns; (iii) Decorative wall insets or projections; (iv) Awnings; (v) Changes in color or texture of materials; (vi) Public art; (vii) Integrated landscape planters; or (viii) Other similar features approved by the Zoning Administrator. 3. Entry Design Vehicle entries to off-street parking structures shall be integrated into the placement and design of adjacent buildings or oriented away from the primary street frontage. At a minimum, parking structures shall provide vehicles access from a location that minimizes conflicts with pedestrian circulation. 4. Height of Parking Structure The height of a parking structure may not exceed the height of the principal building it is intended to serve. Where no principal building exists, the maximum height of the parking structure shall be limited to the maximum building height allowed in the zoning district in which the structure is located. 5. Design of Parking Structures in Form-Based Districts Parking structures in FBZDs must follow the standards established in Article 13.1.7. 5.4.10. MINIMUM OFF-STREET LOADING STANDARDS A. Off-street facilities shall be provided and maintained for receiving and loading of merchandise, supplies, and materials within a building or on the premises. B. Required off-street loading facilities may be adjacent to an existing public alley or private service drive, or may consist of a berth within a structure. C. No portion of a loading facility may extend into a public right-of-way or into an off-street parking facility. D. The off-street loading spaces or truck berths shall provide maneuvering areas on site to prevent any blockage of public right-of-way. E. Off-street loading spaces shall be screened in compliance with the provisions of Section 5.3.3, Screening of Service, Loading, and Storage Areas. 5.4.11. BICYCLE PARKING Bicycle parking shall be designed and located in accordance with the Arlington Hike and Bike System Master Plan, and provided as follows. A. In the EDO district, and where multi-family and mixed-use is permitted within any non-residential zoning district: 1. For all non-residential developments, the number of bicycle parking spaces required shall be five percent of the number of required automobile parking spaces. 2. For multi-family and mixed-use developments, one bicycle parking space shall be provided for every five residential units. 3. 10% of required bicycle parking must include e-bike chargers. B. In all other zoning districts: TABLE 5.4-4: | Required Bicycle Parking Land Use | Number of Spaces Multi-family and Mixed-Use Residential | RMF-22 Zoning District: 10% of all units dwelling | All other Zoning Districts: 20% of the number of units | 10% of required bicycle parking must include e-bike | chargers Hotel, all types | 1 per 30 rooms Public or private school | 1 per 10 students University, college, or seminary | 10% of all automobile spaces Government administration and civic | 1 per 10,000 sf of building area, with a minimum of 2 buildings | spaces Commercial and retail w/off-street | 5% of all automobile spaces with a minimum of 2 spaces parking Commercial and retail w/on-street | 1 per 5,000 sf of building area with a minimum of 2 parking | spaces Industrial | 5% of all automobile spaces with a minimum of 2 spaces Parks and open space | 10% of all automobile spaces C. In all zoning districts, bicycle racks shall be located according to the following, except that in multi-family or mixed-use residential developments they shall be located in a covered and secured area. [image omitted; see the official code] Figure 5.12 Location of bicycle racks.

Amended by Ord. No. 26-019, passed 4-21-2026.

Ask a question about Arlington law

Corpus searches the Arlington sections it holds and shows the ones that match, with their citations. Free, no sign-in.