§ 5.13 — Standards for Mixed-Use Residential Dwellings in Non-Residential Zoning Districts
Code of the City of Arlington, Texas (City Secretary chapter PDFs as posted 2026-11-07, each current through the ordinance named on its cover, with the City Secretary's adopted-not-yet-codified Ordinances 25-063, 25-069, 25-073, 25-074, 25-075, 25-084, 26-003, 26-004, 26-019, 26-024 and 26-027 applied; Anti-Discrimination chapter not included) · Arlington City Code, Unified Development Code Chapter, § 5.13
Corpus is an independent public-information project, not the official City of Arlington website. Stable reference: corpuslaw.us/code/f60990e4-90d0-4c40-ac5f-2d0255a7fc75
5.13. STANDARDS FOR MIXED-USE RESIDENTIAL DWELLINGS IN NON-RESIDENTIAL ZONING DISTRICTS
5.13.1. PURPOSE A. These standards are intended to promote compact, pedestrian-friendly, and transit-supportive patterns of development in mixed-use areas of the city; to guide the organization of mixed-use development in a variety of contexts; and to minimize the visual effects of parking within mixed-use areas. These standards are supplemental to the non-residential design standards and are intended to promote distinct design and sense of place that strengthen mixed-use areas as signature developments. Additionally, the intent of these standards is to ensure: 1. Complements or is compatible with the surrounding uses and community facilities; and 2. Contributes to, enhances, or promotes the welfare of the area and adjacent properties; and 3. Advances the goals of adopted neighborhood or area plans, ensuring the proposed development contributes to cohesive community design, preserves natural features where appropriate, and reinforces connectivity and walkability. 5.13.2 APPLICABILITY A. These standards are applicable to new construction or development of mixed-use residential development or buildings in all non-residential zoning districts, except: 1. When mixed-use is not permitted by Section 3.2, Supplemental Use Standards. 2. In Form-Based Zoning Districts (FBZDs) – Standards in Article 13 apply. B. Applicable overlay district standards contained in Section 2.4, Overlay Districts, must be met, such as streetscape and public realm standards. 5.13.3 USES The following standards shall apply within the mixed-use districts: A. Mix of Uses To provide for a balance of commercial, office, residential, and civic uses, new developments must include a mix of two or more distinct types of permitted uses, with residential uses occupying at least 65 percent all the building or development’s total building square footage. B. Required Mix of Uses—Sites 50,000 Square Feet or Larger All developments on sites that exceed 50,000 square feet of gross floor area must include at least one use from the Commercial Uses category, as identified in Table 3.1-2, Allowed Uses – Non-Residential and Mixed-Use Districts. C. Ground-Floor Uses The incorporation of retail shops and/or restaurants is encouraged at the street level to promote a more active environment for pedestrians and to support residential and office uses located within the same building (on upper floors) or nearby. This configuration of uses is particularly encouraged along major street frontages as well as adjacent to major public spaces, where a high level of activity and visibility is desirable. If a limited portion of a structure’s ground level will be devoted to retail or restaurant space, such space should be located along those façades adjacent to or most visible from primary street frontages or major pedestrian walkways. 1. Refer to Section 5.13.6.J for requirements regarding ground floor commercial aesthetics. 5.13.4. NON-RESIDENTIAL BUILDING CONVERSION A. This section shall apply to an existing building used for office, retail, or warehouse uses that: 1. Proposes to convert at least 65 percent of the building for multi-family dwellings or mixed-use dwellings; 2. At least 65 percent of each floor of the building is fit for occupancy; and 3. Was constructed and finaled at least 5 years before the proposed date to start the conversion. B. The following regulations are prohibited in connection with the use, development construction, or occupancy of such building and conversation: 1. The preparation of a traffic impact analysis or other study relating to the effect the proposed converted building would have on traffic or traffic operations; 2. The construction of improvements or payment of a fee in connection with mitigating traffic effects related to the proposed converted building; 3. The provision of additional parking spaces, other than the parking spaces that already exist on the site of the proposed converted building; 4. The extension, upgrade, replacement, or oversizing of a utility facility except as necessary to provide the minimum capacity needed to serve the proposed converted building; 5. Design requirement, including a requirement related to the exterior, windows, internal environment of a building, or interior space dimensions of an apartment, that is more restrictive than the applicable minimum standard under the International Building Code as adopted as a municipal commercial building code under Texas Local Government Code, Section 214.216; and 6. Impact fees, unless the land on which the building is located was already subject to an impact fee before a building permit related to the conversation was filed with the Zoning Administrator. 5.13.5. SITE DESIGN AND BUILDING ORGANIZATION A. Tree Preservation 1. Must comply with Section 5.2.3, Tree Preservation and Replacement. B. Common Open Space 1. For mixed-use residential buildings with a gross floor area greater than 10,000 and up to 50,000 square feet: 5 percent of total gross site area must be preserved for common open spaces. 2. For mixed-use residential buildings with a gross floor area greater than 50,000 square feet: 7 percent of total gross site area must be preserved for common open spaces. 3. Common open spaces must comply with Section 5.10.3, Common Open Space Standards, of this Code. C. Site Amenities 1. In conjunction with the common open space requirements, all mixed-use projects must provide site amenities from the table below for the residents. 2. Site amenities must be located equitably throughout the development. 3. Within 75 feet of a single-family residential use, all site amenities located above the ground floor must be contained within an enclosed building. 4. Within 75 feet of a single-family residential use, all active site amenities located on the ground floor must be contained within an enclosed building. Active amenities include swimming pools, playgrounds, and sport courts. 5. Mixed-use residential projects must provide the type and number of amenities according to Table 5.13-1 and Table 5.13-2. | TABLE 5.13-1: Site Amenities Table – Mixed-Use Dwelling Districts | Tier 1 2 amenities must be provided from this table | Amenity | | | Standards Dog Park Minimum 1,200 sq ft fenced area with (a) pet waste station, (b) shaded bench, and (c) pet washing station (outdoor spigot with drain or elevated tub). Must not be located within 75 feet of a single-family residential use. Bicycle storage and repair Covered structure with space for minimum 1 bike per 5 station units and a fixed repair stand with basic tools and tire pump. Library and reading area Furnished interior space (min. 150 sq ft) with built-in bookshelves and seating for at least 4. Game/Media room and Shared-use indoor room (min. 300 sq ft) with flexible meeting spaces seating and one built-in screen/projector or monitor Office center and maker Shared-use indoor room with at least 2 workstations, high- space speed internet, and one specialty workstation (e.g., 3D printer, sewing machine, or crafting bench). Fitness center with sauna Fitness room of at least 500 sq ft plus either a dedicated or steam room sauna or steam room with separate ventilation. | TABLE 5.13-2: Site Amenities Table – Mixed-Use Dwelling Districts | Tier 2 1 amenity must be provided from this table | Amenity | | | Standards Swimming pool and Swimming pool: Minimum 400 sq ft in-water surface area shaded children’s play and 600 sq ft adjacent deck. Includes: (a) 4-ft enclosure area (required for projects with self-latching gate, (b) shade structure over part of with more than 80 units) deck, (c) shaded seating for at least 4, and (d) ADA accessibility. Children’s play area: Minimum 800 sq ft outdoor area with: (a) shaded play structure with at least 2 interactive elements, (b) impact-absorbing surface, (c) 2+ benches, and (d) fencing if adjacent to parking or drive aisles. Project-wide Continuous 10-ft-wide loop trail (min. 1,000 linear feet) jogging/walking trails with pet waste stations every 300 ft; must connect at least 3 parts of the site. Rooftop lounge Minimum 500 sq ft rooftop space with built-in seating and shading (e.g., pergola, canopy); ADA-accessible. Centralized courtyard Minimum 1,200 sq ft common courtyard with at least one with prominent artistic or water feature and seating integrated fountain/art/sculpture into the design. Community garden with At least 300 sq ft of raised planting beds, water access, and shed a 40 sq ft storage shed with tools. Natural open space with Minimum 3,000 sq ft open area with: (a) native plantings, outdoor features (b) 2+ shaded benches, (c) shaded playground (unless already required), and (d) shaded outdoor kitchen or grill. Sports Court Full-size court for one of the following: tennis, basketball, volleyball, or pickleball, with appropriate surfacing, striping, and perimeter fencing (as applicable). The Zoning Administrator may approve a half-court if site constraints, design integration, or unit count warrant a reduced configuration. D. Minimum Development Street Frontage/ Build-to-Line A minimum of 60 percent of each development’s total building street frontage along a major arterial must be located at the minimum front setback line for that district. The remaining 40 percent may be set back farther. This percentage may be changed for infill or redevelopment where existing, measurable standards differ from this requirement. In those locations, the new structure must have a street face in keeping with the context of surrounding structures. E. Architectural Setback Encroachments Any architectural feature may encroach up to five feet from the building face into the setback area, unless otherwise approved by the Zoning Administrator, and provided such feature is compatible with the architectural style of the building. No poles or supporting columns are permitted in the street right-of-way. These features may include, but are not limited to: 1. Stairs, stoops, and porches; 2. Chimneys; 3. Awnings and overhangs, which shall provide a minimum of nine feet of clearance above grade; 4. Canopies; 5. Eaves; 6. Tower elements; 7. Pilasters; 8. Bay windows, which shall provide a minimum of 10 feet of clearance above grade and may be no more than 10 feet in width; or 9. Mounted signs. F. Streetfront Building Setbacks 1. Landscape setback areas created by Section 5.2.2, Perimeter Landscape Setback, must be occupied by a minimum eight-foot sidewalks, landscaping, street trees, outdoor dining areas, street amenities, kiosks, plazas, seating areas, and other similar permitted uses and structures. 2. In no instance shall a buffer or setback require more than 25 feet between a property line and a building. G. Throughway Zone At all times, the throughway zone must remain clear of any obstructions. H. Access and Pedestrian Circulation 1. New mixed-use development may be required for public safety access. a. No vehicular access from a mixed-use development shall be provided on a local street serving existing single-family detached development; however, secondary vehicle access for public safety vehicles may be provided onto local streets. 2. New mixed-use development with fewer than 100 units may take primary access from a major collector street, if approved by the Zoning Administrator. 3. See Section 5.2.2.B.6, Landscape at Site Entries for Multi-Family Developments, for site entry landscaping standards. 4. All stairwells and stairways shall be integrated into the design of the building and include a security gate at any exterior point of entry. 5. All secured buildings and communal areas must be accessible for emergency access, such as the use of Knox boxes, and include security cameras and related equipment. 6. All buildings must comply with Section 5.9.4, Pedestrian Circulation. I. Off-Street Parking Standards and Location In addition to all applicable parking standards in Section 5.4, Off-Street Parking and Loading, the following standards must be met. In the event of a conflict, this section controls. 1. Minimum number of parking spaces must comply with section 5.4.3, Off- Street Parking Standards. 2. At least 80 percent of the required number of parking spaces must be provided in covered parking. At least 50 percent of these parking spaces must be located in an enclosed garage. 3. Surface parking may be located between ground-floor non-residential uses and public street. Such parking area shall only include one drive aisle with parking on both sides. In no instance shall surface parking be located between a residential building and the street right-of-way. J. Parking Lot Landscaping. 1. Uncovered Spaces. All uncovered parking spaces must be located within 50 feet of a shade tree. 2. Large Shade Trees. Newly planted trees within the surface parking lot shall only include Shade Trees from the City’s Approved Plant List. K. Accessory Parking and Loading Standards 1. An accessible rideshare pick-up and drop-off location must be provided outside secured gates at the primary access point. 2. At least 15 percent of all required parking spaces must include electric vehicle charging stations. Such stations must be associated with an uncovered parking space accessible to residential tenants and may be counted toward required parking. Off-premise signage shall not be permitted. L. Energy Saving and Environmental Measures 1. Provide at least two passive measures, such as: a. Building orientation directing a majority of windows and doors away from long durations of sun exposure, b. Utilizing preserved trees for shading the proposed building facades, c. Working with existing topography, or d. Minimizing impervious surfaces by careful building footprint/hardscape placement. 2. Provide at least two active measures, such as: a. Solar roofs for the carports and low VOC materials/coatings; b. DarkSky compliant outdoor lighting; c. Rainwater reclamation; d. Bioswales to catch and filter water runoff; or e. Energy efficiency smart home devices in all residences and communal areas. 3. Additional active or passive measures may be approved by the Zoning Administrator. 4. The site plan must include an energy saving and environmental note as to how the development complies with these measures and anticipated impact. The zoning Administrator shall review this note to determine compliance. 5.13.6. BUILDING DESIGN A. Building Height 1. Building height must comply with Section 4.1.6.E, Special Height Limitations in Non-Residential Zoning Districts. B. Building Length Buildings must not exceed 180 feet in length without an unconnected physical separation of at least 15 feet between another building. This separation shall mark the location of a small pedestrian walkway, allowing an access, walkable connection to residential and parking areas behind commercial and retail mixed-use frontage buildings. In areas where shorter building lengths are common, a new structure must match the average building length of the adjacent two structures. If an adjacent lot is empty, the average must be created based on the closest three buildings on the same street face. 1. The pedestrian walkway must be lighted and designed to be safe and visually interesting for pedestrians. 2. The pedestrian walkway must be designed so that it cannot be closed or locked. 3. The pedestrian walkway must be designed to connect separate buildings or link to customer parking. C. 360-Degree Architecture 1. All sides of a mixed-use building shall display a similar level of quality and architectural detailing as on the front elevation. D. Design of Multiple Buildings 1. Design of multiple buildings must comply with Section 5.5.4.F.8, Design of Multiple Buildings. E. Building Corner Treatments Buildings must be designed to reinforce a strong corner condition at street intersections in order to emphasize a “street wall,” in which block closure along the street edge is a definitive characteristic of the development. Buildings must also be designed to accommodate required visibility triangles without compromising the corner design. [image omitted; see the official code] Figure 5.39 Acceptable building corner treatments. F. Building Mass and Horizontal Articulation. 1. Each elevation greater than 50 feet in length, measured horizontally, must incorporate: a. Horizontal articulations having a combined change in articulation of at least 30 percent of the length of the elevation. 2. The elevations of all mixed-use buildings must be articulated through the incorporation of at least six or more of the following: a. Bay or box windows; b. Porches or covered entries that are proportional to the size of the building; c. Dormers; d. Awnings or canopies; e. Structural offsets a minimum of four feet from the principal plane of the façade; f. Accent materials such as brick, stone, or stucco with banding highlights; g. Ornamental or decorative window grills and shutters; h. Variation in window sizes and shapes; i. Vertical elements such as towers or building end-caps that demarcate building modules; or j. Other features as approved by the Zoning Administrator. 3. The height of any part of a mixed-use building shall not exceed 45 feet if the building is located within 75 feet of a property zoned or used for single-family residential. Buildings and parts of buildings located more than 75 feet away are subject to Section 4.1.6.E, Special Height Limitations in Non-Residential Zoning Districts. 4. Mixed-Use buildings must provide concentrated unit access points. Monotonous access balconies and corridors running the length of the exterior of a building are prohibited. G. Roof Form and Vertical Articulation 1. Roof form must comply with Section 5.5.4.F.3, Roof Form. 2. In addition to the vertical articulation requirements cited above, buildings with more than two stories and 100 feet in length along a public street, must include a one additional vertical articulation of one story. Corner buildings must only be required to apply such standard to the elevation with the most linear public street frontage. H. Roofing Design and Materials 1. Roofing design and material must comply with Section 5.5.4.F.4, Roofing Design and Materials. I. Exterior Wall Materials 1. A minimum of two distinct building materials from the preferred material list must be utilized on all façades to provide architectural detail and interest. a. For purposes of this section, preferred materials must be defined as: (i) Stone or brick laid up unit by unit and set in mortar; (ii) Exterior portland cement plaster (stucco) with three coats over metal lath or wire fabric lath; (iii) Cultured stone, cast stone, or natural stone panels; (iv) Architecturally finished block (i.e. burnished block or split faced concrete masonry units), only up to 4 feet above the foundation or surrounding grade; (v) Exterior Insulation and Finish System (EIFS), but only for trim and eaves; (vi) Cementitious fiberboard siding, provided that: (1) It shall only be used on mixed-use structures that are three stories or less in height; (2) Each side of a structure may contain a maximum coverage of 25 percent cementitious fiberboard siding; (3) In no instance shall an elevation parallel and visible from a public street include cementitious fiberboard; and (4) All cementitious fiberboard must be on a minimum 10-year maintenance schedule, which must include repairing missing or broken cementitious fiberboard and repainting. (vii) Metal cladding; or (viii) Other material deemed appropriate for the architectural style, as approved by the Zoning Administrator. (ix) The use of wood for trim, accents, or soffits, may be permitted if approved by the Zoning Administrator. J. Mixed-Use Residential Entry Features All units with frontage along the primary street shall have an entrance that faces the street. Mixed-use buildings with multiple street frontages shall provide entrances to units along each street frontage. 1. Exterior entrances from a public sidewalk or common open space are permitted for dwelling units on the ground floor. These entrances shall be raised from the finished ground-floor level of the sidewalk a minimum of two feet. 2. Dwelling units above the ground floor shall have interior unit entrances, except that exterior stairs are permitted for access to upper-floor units only if they are oriented towards a central plaza not visible from any street. K. Transparency and Commercial Aesthetic 1. At least 40 percent of any ground-floor wall that faces or is visible from a public street, a right-of-way, or a park must contain display areas, windows, or doorways. Windows shall be unobstructed and allow views into working areas or lobbies, pedestrian entrances, or display areas. Blank walls are prohibited. 2. At least 25 percent of walls above 20 feet that face a public street must contain windows. L. Architectural Features 1. The top floor of any building must contain a distinctive finish, consisting of a cornice, banding, or other architectural termination. 2. For all structures three stories or more in height, the base (first 20 feet) of a building must be distinguished from the remainder of the building by providing a minimum of three of the design elements listed above in subsection 5.13.6.E.2, above. 3. Mixed-use buildings must be designed to incorporate visually heavier and more massive elements at the building base, and lighter elements above the base. Upper stories must not appear heavier or demonstrate greater mass than the lower stories of the building. M. Awnings and Overhanging Eaves 1. Awnings and overhanging eaves must be constructed of industry-accepted metal, canvas, and woven vinyl when adjacent to a public street. N. Balconies 1. Generally, all balconies must be inset and flush with the building’s façade. 2. At least 50 percent of studio apartments must include a 20 square-foot balcony. 3. Single-bedroom units must provide at least 30 square feet of balcony space. 4. All other units must provide at least 50 square feet of balcony space with a storage closet. 5. 10 percent of all residential-only ground floor units must provide a minimum 60 square-foot outdoor lawn with a four-foot wrought iron fence and gate. In no instance shall this requirement compete with Section 5.13.6.J, Transparency. O. Garages and Carports 1. All garages and carports must be located at the rear or side of the primary structure. Garages may be integrated into the building with the units. 2. All carports and garages must be designed as an integral part of the architecture of the project. Garages and carports shall be constructed with compatible architectural treatments that match the main buildings (e.g., roof pitch, gable type and orientation, roof materials). 3. For the end support columns of each carport structure, 75 percent of support columns height, as measured from the base, must be wrapped with compatible masonry or stone materials. 4. Gutter systems must be included along the perimeter of all carport rooflines. 5. Carports visible to a public street must screen 50% of the visible side through the use of architectural elements such as louvers, and maintain a 2-foot clearance measured vertically from the parking lot surface. 6. Any enclosed parking structure must be designed so that the only openings at street level are for auto or pedestrian circulation. The remaining street wall of the ground floor shall be wrapped by units or include façade treatments such as projections, recesses, niches, fenestration, or changes of materials or color. 7. All lighting within the carport must be shielded from public view. P. Retaining Walls 1. A retaining wall that is three feet in height or taller and that is not part of an improved drainage channel must be constructed of masonry, stained concrete, or textured concrete. Q. Minimum Dwelling Unit Sizes 1. Minimum dwelling sizes must comply with Section 5.5.2.C, Multi-Family and Mixed-Use Residential Dwelling Unit Sizes. R. Defensible Space 1. Crime Prevention Through Environmental Design (CPTED) best practices, including providing defensible space, opportunities for natural surveillance, territorial reinforcement, and access control, should be incorporated into site, building, and unit design. 2. The concept of private space and control of access points should be reinforced using low fences and landscaping, as appropriate. 3. Window placement between units should balance privacy and natural surveillance. S. Trash and Storage Areas 1. In addition to the requirements of Section 5.3.3.E, Refuse Facility Screened, the standards in this section shall apply. 2. Trash enclosures must be internalized and oriented away from streets and residential areas. Enclosures must be located inside parking areas or at the end of parking bays. Enclosures should not be located adjacent to primary buildings. 3. Trash enclosures must be placed in locations for tenant convenience and pickup service. 4. Enclosures must be architecturally compatible in design to the primary buildings on site using common colors, building materials, and roof materials. T. Mailrooms and Other Accessory Structures 1. Mailrooms, package drop-offs, and mail kiosks must be incorporated within an accessible, secured, and enclosed building. 2. Mailrooms or mail kiosks may be incorporated into another building or separated from all other buildings by a minimum of 20 feet. 3. All mailrooms or accessory structures must be architecturally compatible in design to the primary buildings on site using common colors, building materials, and roof materials. 4. In addition to these standards, all mailrooms and other accessory structures must comply with Section 5.13.5.H, above.
Amended by Ord. No. 26-019, passed 4-21-2026.
Ask a question about Arlington law
Corpus searches the Arlington sections it holds and shows the ones that match, with their citations. Free, no sign-in.