§ 5.3 — Screening, Buffering, and Fences
Code of the City of Arlington, Texas (City Secretary chapter PDFs as posted 2026-11-07, each current through the ordinance named on its cover, with the City Secretary's adopted-not-yet-codified Ordinances 25-063, 25-069, 25-073, 25-074, 25-075, 25-084, 26-003, 26-004, 26-019, 26-024 and 26-027 applied; Anti-Discrimination chapter not included) · Arlington City Code, Unified Development Code Chapter, § 5.3
Corpus is an independent public-information project, not the official City of Arlington website. Stable reference: corpuslaw.us/code/09442e53-274f-4283-bf84-8a7cc0d3e97c
5.3. SCREENING, BUFFERING, AND FENCES
5.3.1. RESIDENTIAL SCREENING AND BUFFERING A. Purpose The purpose of these standards is to ensure that less intensive development is protected from negative effects that may occur when uses that are more intensive or structures are developed on adjacent sites. B. Applicability The residential screening and buffering standards apply when: 1. Development is proposed on any property used or zoned commercial, mixed-use, or industrial that is located adjacent to a residential use and/or vacant property used or zoned residential or multi-family, including those in planned development zoning. 2. Multi-family uses shall comply with the requirements in Section 5.3.1.D, Required Screening and Buffering, and Section 5.3.1.E, Infill Development, when adjacent to residential uses or vacant properties zoned for residential uses. 3. The construction or installation of required residential screening, buffering, or fencing is the responsibility of the non-residential or multi-family property developer. C. Exceptions 1. Residential screening and buffering is not required for uses and structures in the DT-FBZD. 2. Screening is not required for playgrounds for institutional uses or for private parks that do not contain a structure within 30 feet of a common residential property line. 3. The provisions of the Texas Local Government Code Chapter 218, regulating setback and buffer requirements for multi-family and mixed-use residential developments in non-residential zoning districts, shall supersede any requirement in this Section that is more restrictive. D. Required Screening and Buffering 1. Properties subject to this section shall meet the requirements of Tables 5.3- 1 and 5.3-2 below. 2. To use this table, an applicant identifies the zoning or use of his/her property across the top of the table, and then reads down to identify the zoning or use of the adjacent property(ies). The box at the intersection of identifies the screening and buffering requirement for the applicant on that property line. For example, an applicant for a single-story commercial development that is adjacent to single-family residential will need to meet the Level 2 screening and buffering requirements. 3. Different types of screening and buffering may be required on different property lines. | | TABLE 5.3-1: Residential Screening and Buffering | | | | Zoning or Use of Subject Property | Properties Adjacent of Use or Zoning | | Adjacent | | | Subject | | Single-Family | Multi-Family | Mixed-Use | Commercial | Industrial property↓ | property→ Zone District | Structure Type | Res. | | Non- | | Res. | | Non- | | Vert. | Horiz. | | 1-3 | | | 3+ | | -- Res. | Res. | Stories | Stories | Single- | | | Residential | | | 0 | | 1 | 1 1 | 2 2 | 2 3 | 3 Family | | Non-Residential | | 1 | | 0 | | 1 1 | 1 1 | 1 1 Multi-Family | | Residential | | 1 1 | | 0 | | 1 | 1 1 | 2 3 | 3 | Non-Residential | | 1 0 | 1 | | 0 | | 1 1 | 1 1 Mixed-Use | | Vertical | | 2 1 | 1 1 | | 0 | | 0 | 1 1 | 3 | Horizontal | | 2 1 | 1 1 | 0 | | 0 | | 0 1 Commercial | | 1-3 Stories | | 2 1 | 2 1 | 1 0 | | 0 | | 0 | 3 | 3+ Stories | | 3 1 | 3 1 | 1 1 | 0 | | 0 | | 3 | Industrial | | | -- | | 3 3 | 3 3 | 3 3 | 3 3 | | 0 TABLE 5.3-2: Description of Buffer and Screening Requirements * = Additional Requirement ONLY for proposed residential structures | Landscape Buffer Width | Screening Device Level 0 | None | Not required Level 1 | 10 feet | Required. See Section 5.3.4.A.2.c Level 2 | 15 feet | Required. See Section 5.3.4.A.2.b Level 3 | 30 feet* | Required. See Section 5.3.4.A.2.a *For proposed residential use (or mixed-use developments with residential use) adjacent to existing gas well sites: The residential structure shall have a minimum building setback of 300 feet from the nearest gas well drill zone or wellhead. The building setback is measured in a straight line from the nearest edge of the drill zone or gas wellhead. EXCEPTION: This requirement does not apply to existing residentially-zoned properties (as currently zoned) or lots platted for residential uses prior to July 19, 2018. The above exception does NOT apply to properties that changed zoning classifications after the above date. (For example, if a property was previously zoned RE and was changed to RS-7.2 after the above specified date, the 300-foot building setback standard would apply. 4. Screening Standards a. Design of Fences When properties are required or permitted to have a screening device to meet residential screening standards, the standards of Section 5.3.4, Fences, shall apply. b. Location of Fences A screening fence shall be located, to the extent it is practical, along the length of the common line between properties. Required screening fences shall not extend into a required street frontage setback. Access to any required transitional buffer shall be provided for maintenance. 5. Landscape Buffer Design Standards a. Planting Requirements The landscape buffer shall be planted with an evergreen plant mix (see Approved Plant List). This shall include the following: (i) For each 300 square feet of buffer area, one tree with a three-inch caliper that is 10 feet in height at the time of installation. Trees shall be layered into two rows. (ii) Existing vegetation shall be maintained and counted toward the overall landscape requirement where the Zoning Administrator determines that it is healthy and contributes to the overall landscape mix. (iii) The Zoning Administrator may authorize a reduction in the planting ratio where unique property characteristics exist, for no less than one tree for each 450 square feet of buffer area. Trees shall be a three-inch caliper that is 10 feet in height at the time of installation. Trees shall be layered into two rows. b. Permitted Structures and Uses (i) No structures, at or above ground level, including buildings or parking areas (not including driveways) may encroach into the buffer area in non-residential districts. Typical accessory structures and swimming pools may encroach in the buffer area in residential districts. Sidewalks, bike lanes, and/or other street furniture may encroach in all districts. (ii) Loading areas, outside storage, and outside display areas shall not encroach into the transitional buffer area. (iii) Low-impact improvements, as determined by the Zoning Administrator, that are not affiliated with the marketing of any item represented by the development and that do not violate any section of this Code may be permitted in the landscape buffer area. Examples of such low-impact improvements may include, but are not limited to: concrete sidewalks or trails, trails constructed of pervious materials, fountains, putting greens, handicap accessibility ramps, ponds, and decorative lampposts. c. Exceptions (i) The required landscape buffer for non-residential uses and structures allowed in a residential zoning district and located in a more intensive district shall not be required to exceed Level 1 when abutting properties zoned for low-density residential uses but actually used for non-residential uses. Use of this subsection is allowed regardless of the zoning district of the subject property. (ii) Playgrounds or parks that do not contain a structure within 30 feet of a common residential property line, or contain only paving for sidewalks or trails, are not required to have any transitional buffer. E. Infill Development Landscape buffer and screening may be reduced or waived for infill single-family, multifamily, mixed-use, or commercial development where the Zoning Administrator finds the design, height, location of uses, massing, and landscaping of the infill project mitigates potential adverse effects and promotes compatibility with surrounding structures and the character of the neighborhood. F. Residential Screening Across a Street 1. Properties subject to this section that have a side or rear building face that is 1) adjacent to a street, and 2) across the street from properties zoned or used for single-family or two-family dwellings, shall provide a permanent six-foot high minimum and eight-foot high maximum screen at the landscape setback, consisting of a: a. Masonry fence or equivalent material; b. Wood fence as specified in Level 1 screening; or c. Combination of a berm and shrubs planted to create an opaque screen. 2. This subsection shall not apply to the following uses: a. Religious assembly, b. Day care center, c. Public or private school, d. Residential uses, e. Public parks and recreational facilities, or f. Municipal golf courses and driving ranges. G. Outdoor Speakers Properties that are subject to this section shall direct outdoor speakers away from residential uses. H. Special Screening Requirements in Certain Zoning Districts In the FH zoning district, garage bays, service bays and/or loading areas that face a residential zoning district shall be screened to a Level 3 screening. I. Lighting 1. This section shall apply to all multi-family and non-residential uses that abut properties used for residential purposes. 2. Light sources must be indirect, diffused, or covered by shielded type fixtures, and be installed to reduce glare and interference with residential uses. 5.3.2. MECHANICAL AND UTILITY EQUIPMENT SCREENING A. Applicability The standards of this section shall apply to all of the following: 1. Air conditioning and heating equipment; 2. Ductwork used to heat, cool, or ventilate; 3. Swimming pool and spa pumps and filters; 4. Power systems, transformers, and generators for the building or site upon which the equipment is located; and, 5. Similar installations as required by the Zoning Administrator. Roof and/or wall-mounted antennas and vent openings shall not be considered mechanical equipment for purposes of these screening standards. The standards of this section are not intended to impede systems that use solar or wind energy to reduce the costs of energy, if such systems are otherwise in compliance with applicable building codes and zoning requirements. B. Screening Standards 1. Single-Family and Two-Family Residential Screening a. On residential lots, mechanical equipment shall be located behind the building line of the house and screened from public view by a screening device or landscaping. This requirement does not apply to franchise utility boxes. Roof-mounted mechanical equipment, except solar energy systems, is prohibited on single-family residential dwellings. b. Utility equipment located in the public right-of-way or designated open spaces shall be screened with a screening device or landscaping, or a combination of the two. Such screening or landscaping shall be maintained by the adjacent property owner or the community’s homeowners association or public improvement district. c. For attached single-family development, window mounted air-conditioning units are prohibited. 2. Multi-Family, Mixed-Use, Commercial, and Industrial Screening For all developments other than single-family residential, the following mechanical equipment screening standard shall apply to the maximum extent practicable. a. Roof-Mounted Mechanical Equipment Roof-mounted mechanical equipment shall be screened by a parapet wall or similar feature that is an integral part of the building’s architectural design. The parapet wall or similar feature shall be of a height equal to or greater than the height of the mechanical equipment being screened so that such equipment is not visible from a point six feet above any portion of the opposing sidewalk or above the crown of the abutting street, whichever is greater. b. Wall-Mounted Mechanical Equipment Wall-mounted mechanical equipment that protrudes more than six inches from the outer building wall shall be screened from public view by structural features that are compatible with the architecture of the subject building. Wall-mounted mechanical equipment that protrudes six inches or less from the outer building wall shall be designed to blend with the color and architectural design of the subject building. Window mounted air-conditioning units are prohibited in multi-family and mixed-use developments. c. Ground-Mounted Mechanical Equipment Ground-mounted mechanical equipment shall be screened from view by landscaping or by a decorative fence that is compatible with the architecture and landscaping of the development site. The fence shall be of a height equal to or greater than the height of the mechanical equipment being screened. C. Alternate Screening Where site constraints or other design limitations are present, the Zoning Administrator may allow mechanical equipment that is not screened in full compliance with the screening standards of this section to use alternative screening methods. Alternate screening methods may include, but shall not be limited to, increased setbacks, increased landscaping, grouping the equipment on specific portions of a site, and painting or otherwise camouflaging the equipment. D. Distinct Materials Materials used to construct the mechanical and utility screening required by this Section 5.3.2 shall not count towards compliance with the design requirements of Article 5 for distinct building materials on facades. 5.3.3. SCREENING OF SERVICE, LOADING, AND STORAGE AREAS A. Applicability These screening requirements are applicable to all service, loading, and storage areas. B. Placement 1. All service areas shall be placed at the rear, on the side of, or inside buildings. 2. No service area shall be visible from a public right-of-way or from adjacent residential areas. 3. Service areas and access drives shall be located so they do not interfere with the normal activities of building occupants or visitors on driveways, walkways, in parking areas, or at entries. C. Outside Storage and Display Areas, Service Areas, and Loading Docks All outside and display storage areas, service areas, and loading docks not screened by an intervening building shall be screened from view from any public street right-of-way. In addition, storage and loading areas shall be screened from view from any adjoining property when that property requires a transitional buffer as identified in Table 5.3-1 of this article. Property zoned or used for industrial purposes shall also screen from view all outside storage areas that are adjacent to non-industrial-zoned property. [image omitted; see the official code] 1. The screening device shall consist of an opaque architectural screen or fence that substantially conforms to the color, detailing, and building materials of the principal structure. The height of the device shall not be less than the height of the materials stored. 2. Screening shall be a minimum height of eight feet to screen truck berths; loading docks; and areas designated for permanent parking or storage of heavy Figure 5.6 Screening of loading docks and storage areas vehicles, equipment, or materials. 3. Screening shall be long enough to screen the maximum size trailer that can be accommodated on site. Sites that can accommodate a full size tractor-trailer shall provide a 48-foot wing wall, where wing walls are used. D. Shopping Cart Storage 1. Shopping cart corrals shall be made of a material suitable for withstanding weathering and rusting. Plastic corrals are prohibited. 2. All shopping carts shall be stored overnight inside the building they serve. Overnight storage is not permitted in the corrals. E. Refuse Facility Screened 1. All refuse facilities, including new refuse facilities placed on an existing development, shall be large enough to accommodate a trash dumpster and shall be completely screened from view of public streets and adjoining non-industrial zoned properties by: a. Screening on three sides by a minimum eight-foot masonry fence enclosed by an evergreen living screen. Screening shrubs shall be a minimum of four feet in height at installation and shall provide a minimum six-foot high screen when fully grown. b. An opening shall be situated so that the container is not visible from adjacent properties or public streets. The opening shall include a metal-clad opaque gate. Chain-link gates are not permitted. Gates shall have tiebacks to secure in the open position. 2. Screening is not required if the refuse facilities are otherwise screened from view by intervening buildings. 3. Screening is not required if the refuse facilities are located within a parking structure. F. Stacking Lane for Drive-Through Service Windows Screened Stacking lanes for drive-through service windows shall be screened according to the following: 1. Stacking lanes for drive-through service windows shall be screened to a height of three feet between the lane and the adjacent parking or maneuvering areas. 2. Screening shall be opaque and consist of one or a combination of screening shrubs, fences, and/or berms. 3. Screening shrubs shall be spaced a minimum of three feet on center. The shrubs shall be a minimum planting size of five gallons and shall be capable of reaching a minimum height of three feet within 18 months of planting. G. Design of Screening All screening shall be complementary to the building served in landscaping approach and through the use of similar colors and material palette. 5.3.4. FENCES A. Single-Family and Two-Family Residential Fencing 1. Applicability a. These standards are applicable in all zoning districts, except the following: (1) Planned Development districts that have specific fence design standards, (2) Entertainment District (EDO) overlay district, (3) Village on the Green at Tierra Verde (VG) district, (4) Downtown Form-Based Zoning District (DT-FBZD) that have specific fence design standards, and (5) Conservation District (CDO) overlay districts that have specific fence design standards. b. Section 5.3.4.A.2, Residential Fencing Types, is applicable to replacement and new residential fences as further described in that section. c. Compliance with the requirements listed below shall be reviewed with each fence permit application. d. For the purposes of this section, the term “fence” is used to mean “a structure serving as an enclosure, a barrier, or a boundary.” 2. Residential Fencing Types a. Residential fencing standards are divided into two main categories: perimeter fencing and privacy fencing. (1) Perimeter fencing is required to be completely installed by the developer for the boundary of the approved final plat in the areas as set forth below, prior to the issuance of a building permit. The Zoning Administrator may, but is not required to, authorize the issuance of building permits for up to 10 percent of the residential lots in the development prior to complete installation of perimeter fencing. No dwelling unit within the development shall be approved for occupancy until the perimeter fencing has been completely installed. (2) Privacy fencing is an option left up to the builder or homeowner, but if built it shall follow the standards listed below. b. Adjacent to Major Thoroughfares and in Level 3 Screening and Buffering Areas In the interest of public safety and privacy, the following standards shall apply for all perimeter fencing on lots where the rear and/or side yards are adjacent to a freeway, major arterial, minor arterial, or major collector as identified on the Thoroughfare Development Plan, or where Level 3 screening and buffering is required: (1) Height Six feet minimum and eight feet maximum, measured from the highest adjacent grade within ten feet of the fence. In order to create variation in the design of the fence, at certain locations for no more than 10 percent of the total linear length of the fence, the height may be increased to 10 feet with approval from the Zoning Administrator. (2) Approved Materials 100 percent masonry (brick, stone, architecturally finished reinforced concrete), or any other sustainable material with more than 30-year life expectancy to give a long lasting, aesthetically pleasing appearance. Materials should preferably have a low maintenance factor and be complemented with landscaping, where appropriate. Ornamental metal rail fencing may be used to provide at least 50 percent transparency for the portions of the subdivision abutting an internal park/open space or to emphasize the landscaping at the entrance. (3) Prohibited Materials Chain link, vinyl, and wood fencing are prohibited. (4) Design Adjacent to major thoroughfares, the fence should be curved or angled at corner locations to accommodate appropriate visibility and add variety. Wall sections greater than 50 feet in length should incorporate at least one of the following design features that are proportionate to the fence length: (a) A minimum one foot change in fence plane and height for at least ten feet, after at least every 20 feet; (b) A minimum 18-inch raised planter at least eight feet long, after at least every 35 feet; (c) Use of columns at 35-foot intervals; or (d) Any other feature, approved by the Zoning Administrator that provides adequate relief from the monotony of a continuous fence. (5) Construction Standard It is intended that all fences erected pursuant to this section be constructed in such a manner to last 30 years with minimal maintenance required during said period. As such, all fences required by this section shall conform to the following minimum standards: (a) The Zoning Administrator shall approve plans and specifications for fences and foundations. Such plans and specifications are to be submitted at the same time as construction plans for other subdivision infrastructure improvements are required. (b) Fences shall be located on or within the private property and outside of the public right-of-way. Fences may be in an offset configuration as long as there is no encroachment into the right of way. (c) The material, color, and design of fences shall be uniform within an approved preliminary plat, unless otherwise approved by the Zoning Administrator. (d) All fences shall be placed at least nine feet from any existing or proposed City water line. Where necessary for compliance, the developer shall be required to provide up to an additional nine feet of right-of-way. (e) It shall be the responsibility of any person, firm, corporation or other entity who shall own or occupy any lot or lots on which a fence was constructed pursuant to the terms of this section to adequately maintain the fence and to prevent it from becoming dilapidated or unsightly, unless otherwise specified as the responsibility of a mandatory homeowners association or public improvement district. c. Adjacent to Minor Collector and Local Streets and in Level 2 Screening and Buffering Areas The following standards shall apply for all perimeter fencing on lots where the rear and/or side yards are adjacent to a minor collector or a local street or in areas where Level 2 screening and buffering is required: (1) Height Six feet minimum and eight feet maximum, measured from the highest adjacent grade within ten feet of the fence. (2) Approved Materials (a) 100 percent masonry (brick, stone, architecturally finished reinforced concrete), or any sustainable material with more than a 30-year life expectancy; (b) Ornamental metal rail fencing may also be used in combination with any of the masonry materials listed above; (c) Composite fencing or vinyl fencing in a natural tone flat color such as rust or tan; and, (d) Cedar or redwood is permitted, but only if used with metal posts, metal brackets, and metal caps. Wood posts are prohibited. The side of the fence with the exposed posts or rails shall be oriented away from view from the adjacent public street. (3) Prohibited Materials Chain link fencing is prohibited. d. Level 1 Screening and Buffering Areas The following standards shall apply in areas where Level 1 screening and buffering is required: (1) Height Six feet minimum and eight feet maximum, measured from the highest adjacent grade within ten feet of the fence. (2) Approved Materials (a) 100 percent masonry (brick, stone, architecturally finished reinforced concrete), or any sustainable material with more than a 30-year life expectancy; (b) Composite fencing or vinyl fencing in a natural tone flat color such as rust or tan; and (c) Double-sided wood stockade fence with metal posts, metal brackets, and metal caps. A continuous six-inch tall by eight-inch wide concrete mowing edge shall be provided. (3) Prohibited Materials Chain link fencing is prohibited. e. Privacy Fences on Single-Family Residentially Zoned Lots (1) Applicability This section applies to replacement of residential fences or construction of new fences. A fence permit is required when more than 50 percent of the length of the fence along a property line is being replaced. (2) Height Height shall not exceed eight feet as measured from the highest adjacent grade within ten feet of the fence. (3) Approved Materials (a) Masonry (brick, stone, reinforced cement concrete) or any other sustainable material with more than a 30-year life expectancy; (b) Ornamental metal rail fencing; (c) Cedar and redwood; (d) Composite fencing; (e) Vinyl fencing in flat white or flat natural tone colors such as rust or tan; and, (f) Other wooden picket fences, only if constructed with metal posts, metal brackets, and metal caps. Chemically pre-treated wooden horizontal members shall be at least 2” X 4”. (4) Prohibited Materials (a) Chain link; (b) Sheet, roll, or corrugated metal; and, (c) Cast off, secondhand, or other items not originally intended to be used for constructing or maintaining a fence. (5) Chain Link Reconstruction Materials An existing chain link fence may be replaced with a new chain link fence or be replaced with an approved material. If the existing fence is not chain link, the fence may be repaired with the existing material or an approved material. (6) Orientation of Fence When any stockade fence or other screening device, whether required or not, is located on a lot adjacent to a public street, said fence or screening device shall orient the side with exposed posts or rails away from view from the adjacent public street. (7) Location of Fence Privacy fences may be located along the property line with the following exceptions: (a) In the interest of public safety and considering the visibility triangles, no fence may be taller than two feet when located on the side property lines of a corner lot or a reverse corner lot. (b) Any fence that is more than two feet high shall be set back at least five feet from the side property line of a corner lot. In the case of a reverse corner lot, any fence that is more than two feet high shall be set back at least 7.5 feet from the side property line. f. Adjacent to Parkland or an Internal Designated Open Space The following standard shall apply for all privacy fences where the rear and/or side yards share a common property line with a dedicated private open space or parkland as identified on the Parks Master Plan. (1) Height Height shall not exceed eight feet as measured from the highest adjacent grade within ten feet of the fence. (2) Approved Material (a) Ornamental metal rail fencing with columns (brick or stone) or ornamental metal posts shall be used to provide at least 50 percent transparency. Vinyl fencing in a natural tone flat color such as rust or tan may also be used and shall provide the same percentage of transparency as ornamental metal rail fencing for lots adjacent to internal open spaces only. (b) In the interest of privacy, homeowners may choose to plant vines or shrubs along the fence on their property. (3) Prohibited Materials (a) Chain link; (b) Wood; (c) Sheet, roll or corrugated metal; and (d) Cast off, secondhand or other items not originally intended to be used for constructing or maintaining a fence. g. Fences in Front Yard Setback (1) Height Height shall not exceed three feet above the average established grade at the front lot line and in the street front setback; provided, an ornamental metal rail fence may be built not to exceed four feet in height. (2) Approved Materials Such fences shall be constructed using the following materials: (a) Vinyl or composite open picket fencing with at least 50-percent visibility. (b) Ornamental metal rail fencing with at least 75-percent transparency. (c) Masonry columns may be used, provided they are constructed of brick, stone, reinforced concrete, or any sustainable materials with more than a 30-year life expectancy. (3) Prohibited Materials (a) Cedar, redwood, or other wood products; (b) Chain link; (c) Sheet, roll or corrugated metal; and, (d) Cast off, secondhand or other items not originally intended to be used for constructing or maintaining a fence. h. Special Provisions for Fences for Townhouses, Large Lots, and Agricultural Uses Special provisions to increase the height of a fence located in the minimum front yard are allowed for a townhouse development as well as lots one acre in size or larger if the following requirements are met. (1) Townhouse Block with Rear-Loaded Garages Ornamental metal rail fences up to four feet in height shall be allowed along the front lot line. The metal rail fence shall be used in combination with masonry columns, which shall not exceed the height of the fence by more than six inches. Such fences shall provide at least 75 percent transparency. (2) Townhouse Block with Front-Loaded Garages Ornamental metal rail fences up to four feet in height shall be allowed beginning at a point of at least eight feet from the front lot line, in order to maintain visibility at drive approaches. The metal rail fence shall be used in combination with masonry columns, which shall not exceed the height of the fence by more than six inches. Such fences shall provide at least 75 percent transparency. (3) Lots One Acre in Size or Larger The minimum front yard fence requirements may be modified in compliance with this subsection. (a) Height The height shall not exceed eight feet measured from the highest adjacent grade within ten feet of the fence. (b) Approved Materials Wrought iron, ornamental steel or any permanent, architecturally equivalent material. Masonry may be used in combination with these materials, provided that no more than 25 percent of the fence, measured in linear feet, is solid. (c) Location The fence shall not be located within setbacks that may be required for traffic safety purposes, as determined by the Zoning Administrator. (4) Agricultural Uses Fences constructed on lots with permitted agricultural uses may be constructed in compliance with this subsection, subject to approval by the Zoning Administrator. (a) Height The height shall not exceed six feet measured from the highest adjacent grade within ten feet of the fence. (b) Approved Materials (i) Post and rail construction; (ii) Pipe and cable construction; (iii) Rail pipe; or (iv) Woven wire. (c) Prohibited Materials (i) Barbed wire; or (ii) Electric fencing. B. Fencing in Non-Residential and Mixed-Use Districts 1. Other than required screening fences, fencing in non-residential and mixed-use zoning districts, or for commercial uses located in residential or industrial districts, shall conform to the following minimum standards: a. The height shall not exceed eight feet as measured from the highest adjacent grade within ten feet of the fence. b. Fences and gates that exceed four feet in height shall not extend beyond the front façade of the building. c. Chain link; vinyl; and sheet, roll or corrugated metal are prohibited materials for fencing and gates. The Zoning Administrator may approve the use of chain link for playground areas associated with day care centers or public or institutional uses. 2. Other than required screening fences, fencing for industrial uses located in the LI and IM districts shall conform to the following minimum standards: a. The height shall not exceed twelve feet as measured from the highest adjacent grade within ten feet of the fence. b. Fences and gates that exceed four feet in height shall not extend beyond the front façade of the building, unless approved by the Zoning Administrator. c. Chain link or vinyl fencing are permitted materials for security fencing. d. Sheet, roll or corrugated metal; or cast off, secondhand or other items not originally intended to be used for constructing or maintaining a fence are prohibited materials for fencing and gates. 3. Electric fences shall conform to the following minimum standards: a. Electric fences are permitted only in the IM zoning district, except that electric fences are prohibited in DT-FBZD and EDO district. b. An electric fence shall not extend beyond the front façade of the building. c. The height of an electric fence shall not exceed 12 feet at its highest point measured at existing grade. d. Electric fences shall not be installed within five feet of a door to the building, or within 30 feet of a property line zoned or used for residential purposes. e. Electric fences shall be clearly marked with warning signs. The warning signs shall be placed not more than 50 feet apart around the entire perimeter of the fence and be visible from both sides of the fence. f. Electric fences shall use an interrupted or pulsating current not exceed 7,000 volts. The use of an uninterrupted current is prohibited. The fence may only be charged over a system derived from a system powered by a direct current battery and shall not be connected to an alternating current electrical system. Devices shall be listed by a nationally-recognized testing laboratory. g. A Knox security system or other approved access device shall be installed for emergency access by the police or fire departments. All electric fences shall be registered with the police department through an alarm permit. h. All electric fences shall comply with all applicable building, construction, and electrical codes adopted by the City. 4. Fencing along public right-of-way may be used to delineate sidewalk seating areas for cafes and restaurants and shall conform to the following minimum standards: a. Maintain primacy of the public right-of-way for pedestrian and vehicular movement. b. Ensure a compatible relationship with adjacent streetscape elements and building architecture. c. Maintain barrier-free access for persons with disabilities. d. Maintain a safe, secure, and comfortable environment for pedestrians. e. The design, materials, and colors used should be compatible with the streetscape. f. Perimeter fences should not obstruct the line of sight for pedestrians and drivers. C. General Fence Maintenance 1. All screening fences constructed as required by this Code, previous ordinances, or other approvals must be perpetually maintained, repaired, or replaced by the owner of use of the more intensively zoned property. For purpose of this section, owner of the property for which the fence permit was issued is presumed to be the owner of the fence. 2. All fences shall be maintained in accordance with the requirements of the Nuisance Chapter, the Construction Chapter, and any other provisions of the City of Arlington Code of Ordinances regulating fences. 3. Repair and Replacement of Fences. a. For fences where 50 percent or more of one length of fence along a property line requires repair or replacement with new fencing materials, a fence permit must be obtained in accordance with the Construction Chapter. b. For fences where less than 50 percent of one length of fence along a property line requires repair or replacement with new fencing materials, the repair or replacement: (1) shall not change the scope, location or dimensions of the fence; and (2) shall be made using the same material as originally used to construct the fence, or material with comparable composition, color, size, shape, and quality as the remaining fencing material. c. Repair and replacement of fences must comply with all applicable provisions of this Code. 4. Notwithstanding any other provision, the use of materials not specifically manufactured for the construction of fences is strictly prohibited. These include, but are not limited to, plywood, corrugated steel panels, or fiberglass panels. 5.3.5. VISIBILITY TRIANGLES MAINTAINED Visibility triangles shall be maintained as required in the “Streets and Sidewalks” chapter of the Code of the City of Arlington.
Amended by Ord. No. 26-019, passed 4-21-2026.
Ask a question about Arlington law
Corpus searches the Arlington sections it holds and shows the ones that match, with their citations. Free, no sign-in.
