For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 5.5 — Residential Design Standards

Code of the City of Arlington, Texas (City Secretary chapter PDFs as posted 2026-11-07, each current through the ordinance named on its cover, with the City Secretary's adopted-not-yet-codified Ordinances 25-063, 25-069, 25-073, 25-074, 25-075, 25-084, 26-003, 26-004, 26-019, 26-024 and 26-027 applied; Anti-Discrimination chapter not included) · Arlington City Code, Unified Development Code Chapter, § 5.5

Corpus is an independent public-information project, not the official City of Arlington website. Stable reference: corpuslaw.us/code/ed0549d0-fb6d-4692-a5a4-a1655239fe5d

5.5. RESIDENTIAL DESIGN STANDARDS

5.5.1. PURPOSE The standards of this section are intended to: A. Promote high-quality residential developments that are distinctive, have character, and relate and connect to established neighborhoods; B. Provide variety and visual interest in the exterior design of residential buildings; C. Create new sustainable neighborhoods that age gracefully and add long term value to the city; D. Enhance the residential streetscape and diminish the prominence of garages and parking areas; E. Protect property values; and F. Ensure the compatibility of infill residential development with the existing character of surrounding neighborhoods. 5.5.2. GENERAL STANDARDS FOR ALL RESIDENTIAL DEVELOPMENT A. Residential Infill Compatibility Standards 1. Applicability These residential infill compatibility standards shall apply to any development of a new residential use or substantial renovation of an existing residential use that meets the following requirements: a. Located in the NMU, RMU, or LPO districts, or any residential use district platted prior to January 31, 1984; b. Not a part of a planned development; c. Meets the applicability standards of this article; d. Is proposed on a lot that abuts existing structures on at least three sides; and e. Is served by existing water, sanitary sewer, and streets. f. Standards for residential infill in Form-Based Zoning Districts shall meet Article 13.1.7 in lieu of this section. 2. Contextual Front Building Setbacks Notwithstanding the minimum front setback requirements required in Article 4, Dimensional Standards, for the zoning district in which the property is located, the applicant may use a contextual front setback when existing front setbacks on the same block are greater or less than that required by the underlying zoning. In such circumstance, the front setback for the proposed development shall be set back no further from the primary street than the furthest front façade of the principal building on either of the two abutting lots in the same base zone district, and shall be located no closer to the primary street than the closest front façade of the principal structure on either of the two abutting lots in the same base zone district. 3. Appearance Infill development shall be constructed to be generally compatible in appearance with other existing structures on the block that comply with this Code. This provision shall be satisfied by constructing the proposed building(s) so that at least three of the following features are substantially similar to the majority of other buildings on the same and facing block: a. Roof material; b. Roof overhang; c. Exterior building material; d. Shape, size, and alignment of windows and doors; e. Front porches or porticos; f. Exterior building color; or g. Location and style of garage or carport. 4. Multi-Family Infill Adjacent to Single-Family Residential New multi-family infill development that will be located on a block face where more than 75 percent of the existing homes are single-family shall employ one or more of the following techniques to help reduce the overall bulk and mass of individual buildings and help maintain a lower-intensity residential character along the street frontage: a. Articulate the front façade so that [image omitted; see the official code] the building appears from the street to be separate homes by “stepping back” the front façade a minimum of 10 feet at the traditional side yard setback that would typically be found between two single-family homes; b. Organize units around a central Figure 5.13 Multi-family units with front courtyard that maintains the façade step-back impression of the traditional side yard setback between units along the street frontage; or c. Design the multi-family building so that the massing, arrangement of architectural elements, and use of exterior materials gives the appearance of a large single-family home. B. Mix of Housing Types 1. Intent These standards are intended to promote a more diverse community through the provision of a variety of housing types, and to encourage developments that are not dominated by a single type of home or dwelling unit. 2. Required Mix A development of 20 units or more shall include a minimum housing mix of at least three models, with a minimum of three distinct street-facing elevations per model. C. Multi-Family and Mixed-Use Residential Developments 1. Multi-Family and Mixed-Use Residential Dwelling Unit Sizes a. All multi-family and mixed-use residential developments must comply with the following minimum unit sizes: (i) 600 square feet for efficiency or studio units; (ii) 750 square feet for 1-bedroom units; (iii) 900 square feet for 2-bedroom units; (iv) 1,100 square feet for 3-bedroom units; and (v) 1,100 square feet, plus 125 square feet, for each additional bedroom with 4 or more bedrooms. 5.5.3. STANDARDS FOR SINGLE-FAMILY AND TWO-FAMILY RESIDENTIAL DWELLINGS A. Purpose and Intent The purpose of these standards is to establish requirements for sustainable residential development throughout the city, increase the value of Arlington’s housing stock, and ensure that homes are attractive and of high quality. Specifically, the goals for single-family and two-family developments are: 1. Construct new neighborhoods that age gracefully and become established over time. Utilize sustainable design principles so that residences do not deteriorate. 2. Construct residential infill or redevelopment such that it enhances the value and quality of existing neighborhoods. 3. Promote the development of attractive streetscapes, which increase curb appeal, create a ‘sense of place’, and enhance Arlington’s image. 4. Provide flexibility for variety. The intent of these standards is to prohibit certain design elements that have a negative effect on communities, while simultaneously allowing developers a great deal of latitude to create interesting, attractive developments. B. Applicability 1. These standards are applicable to new construction or redevelopment of single-family and two-family dwelling units in all zoning districts, except the following: a. Planned Development districts that have specific residential design standards but only to the extent such standards differ from the standards of this Section 5.5.3; b. Landmark Preservation (LPO) Overlay District; c. Conservation District overlays that have specific residential design standards; and d. Form-Based Zoning Districts. 2. Communities for which a plat application has been made prior to the adoption of the residential design standards will be subject to only the building design and front yard landscaping requirements. In those communities, these standards will be applicable only for building permit applications submitted to the City after two years from the later to occur of the date the City signs the final plat, or the date the City accepts the subdivision improvements offered for public dedication, if any. C. Building Design Standards Applicable to All Single-Family and Two-Family Residential 1. Intent The building design standards are intended to create unique neighborhoods by utilizing a wide array of architectural elements and design techniques. The purpose of these requirements is not to dictate how residences are designed; rather, it is to ensure that communities possess a distinct character and are desirable places to live for many years to come. Compliance with the requirements listed below shall be reviewed with each building permit application. 2. Orientation of Main Entrance a. The main entrance or a courtyard leading to the main entrance of each primary structure shall be located on the front façade. b. On corner lots, the main entrance shall face one of the streets or be oriented to the corner. 3. 360-Degree Architecture a. The primary material on the front façade of the house shall be continued on all sides of the house, and on at least 50 percent of each side. b. Windows are required on all elevations. On public facing façades (streets or parks), windows and doors shall cover a minimum of 20 percent of the elevation. c. Window and door openings shall be articulated on all elevations of the building through the use of: (i) Shutters, (ii) Enhanced flat or arched lintels and sills (projecting or recessed, or constructed of materials other than the primary building material), (iii) Overhangs, or (iv) Surrounds and trims. 4. Building Foundations Foundations of exterior walls or piers exposed more than ten inches above the adjacent ground level shall be clad in the primary exterior finish material, such as brick, stone, or stucco, or stained to complement the primary exterior finish material. 5. Exterior Finish Materials a. Exterior finish materials shall be durable and consistent with the architectural style of the community. b. Preferred Materials: One hundred percent of the primary residential structure shall consist of the following masonry materials. This coverage calculation does not include doors, windows, recessed entries, chimneys, dormers, window box-outs, bay windows that do not extend to the foundation, or any other exterior wall that does not bear on the foundation. (i) Stone or brick laid up unit by unit and set in mortar, (ii) Cultured stone, (iii) Exterior portland cement plaster (stucco) with three coats over metal lath or wire fabric lath, or (iv) An equivalent, permanent architecturally finished material with a minimum 30-year warranty period is also acceptable. c. Exterior walls of chimneys, dormers, window box-outs, bay windows that do not extend to the foundation, or any other exterior wall that does not bear on the foundation, is preferred to be constructed of masonry materials or any other sustainable material with a minimum 30-year warranty period, such as: cementitious fiberboard, seamless steel siding, vinyl siding with a flat or low gloss embossed finish and at least 0.04-inch thick, three-coat stucco, or EIFS. Fascia may be constructed of sustainable materials with a minimum 20-year warranty period covering the product and its coating, such as: cementitious fiberboard, aluminum coil with vinyl coating, cedar wood, redwood, treated engineered wood, or treated dimensional lumber. d. An expression line such as a trim band or capping shall be utilized when transitioning from one material to another or to a different color in the same material vertically. 6. Retaining Walls A retaining wall that is three feet in height or taller and that is not part of an improved drainage channel shall be constructed of masonry, stained concrete, or textured concrete. D. Building Design Standards Applicable to Two-Family and Detached Single-Family Residential 1. Entry Feature Entry features shall meet the following design standards: a. A dwelling shall include a covered front porch, stoop, recessed entry, or front courtyard at the main entrance. An entry feature designed in accordance with the style of the dwelling unit is also acceptable. For zero-lot-line developments, side courtyards with wrought iron fencing may also serve as an entry feature. b. The minimum area of a porch, [image omitted; see the official code] stoop landing, recessed entry, or courtyard shall be 20 square feet. c. The height of the main entry feature shall be scaled appropriately for the individual dwelling. On two-story homes, the roof eave of the entry feature shall not extend up to or above the Figure 5.14 Front porch scaled appropriately. highest roof eave of the structure. The roof ridge of the entry feature shall not extend up to or above the highest roof ridge of the structure. d. In order to increase the entry’s prominence, the entry shall have at least one of the following: sidelights; a glass transom; decorative detailing on the front door such as raised/recessed panels, arches, glazing, or wrought iron details; or similar features. 2. Garage Location Garages shall be situated so that they are not the predominant design feature of the dwelling based on the following standards. a. Front loading, front facing garages shall not project out from the front façade of the building. b. Front loading, front facing garages shall not constitute more than 55 percent of the total width of the dwelling. Garage width shall be measured as the sum of the width of the front facing garage opening(s). c. All front-loading, front facing [image omitted; see the official code] garages shall incorporate at least two different architectural elements. However, garages recessed less than seven feet from the front façade shall incorporate four different architectural elements. Architectural elements may include balconies or other Figure 5.15 Example of J-swing garage. decorative overhangs above doors, columns flanking doors, decorative banding or moldings, detailed door designs with larger decorative brackets, windows/openings on garage doors, arches, decorative vent covers on a gable above the garage, sconce lighting, or similar elements. d. No more than two car bays may share a common garage door. 3. Additional Architectural Design Feature for Front Elevation Variation in front elevations shall be used to add character and interest to communities. While some common elements may be shared, aspects such as color, material, detailing, landscaping, different floor plans, and different façade treatments shall be used to differentiate homes. 4. Roof Design Roof design shall be varied to break up the mass and perceived bulk based on the following standards: a. A minimum roof pitch of 6:12 shall apply to gable, hip, or shed roofs. This does not apply to portions of a roof that are separate from the structure’s primary roof. b. Flat roofs shall be screened by a parapet wall, capped by a three-dimensional cornice treatment. c. Architectural styles that incorporate eaves shall have the eaves extend from the building wall at least 12 inches as measured horizontally on all façades. The Zoning Administrator may approve a shorter distance for roofs with a pitch of 12:12 or greater. d. The use of proportionally designed dormers on the roof is encouraged where they are appropriate to the architectural style of the home. 5. Driveway and Front Yard Setback Pavement a. The driveway length of front loading, front facing garages shall be no less than 20 feet from the front property line. In case of communities with private streets, the 20-foot distance shall be measured from the edge of the sidewalk farthest away from the street and parallel to the street. b. The total area of all pavement in the required minimum front yard setback, including the driveway, shall not exceed one-half of the area of such setback, or 600 square feet, whichever is less. c. The installation of pavement in the required minimum front yard setback shall be prohibited, except when approved by permit and subject to the limitations of this Section. E. Building Design Standards Applicable to All Two-Family and Attached Single-Family Residential 1. Entry Features Entry features shall meet the following design standards. a. A dwelling shall include a covered front porch, stoop, recessed entry, or front courtyard at main entrances. An entry feature designed in accordance with the style of the dwelling unit is also acceptable. b. The minimum area of a porch, stoop landing, recessed entry, or courtyard shall be 20 square feet. c. No primary entrance of a dwelling unit shall be located on the second story of a structure. d. The height of the main entry feature shall be scaled appropriately for the individual dwelling. On two-story homes, the roof eave of the entry feature shall not extend up to or above the highest roof eave of the structure. The roof ridge of the entry feature shall not extend up to or above the highest roof ridge of the structure. e. In order to increase its prominence, the entry shall have at least one of the following: sidelights; a glass transom; decorative detailing on the front door such as raised/recessed panels, arches, glazing, or wrought iron details; or similar features. 2. Garage Location Garages shall be situated so that they are not the predominant design feature of the dwelling based on the following standards: a. Front loading, front facing garages shall not project out from the front façade of the building. b. Front loading, front facing garages shall not constitute more than 60 percent of the total width of the dwelling. Garage width shall be measured as the sum of the width of the front facing garage opening(s). c. All front-loading, front facing garages shall incorporate at least two different architectural elements. However, if the garage is recessed less than seven feet from the front façade or flush with the front façade, it is required to incorporate enhanced driveway paving and three different architectural elements. Architectural elements may include balconies or other decorative overhangs above doors, columns flanking doors, decorative banding or moldings, multiple panel door designs or other architectural detailing with larger decorative brackets, windows/openings on garage doors, arches, decorative vent covers on a gable above the garage, sconce lighting, or similar elements. d. No more than two car bays may share a common garage door. 3. Driveways Driveways should be deep enough to provide sufficient room for vehicles to park without encroaching into the sidewalk to allow pedestrians and others to use the sidewalk. a. The driveway length of front loading, front facing garages shall be no less than 20 feet from the front property line. In case of communities with private streets, the 20-foot distance shall be measured from the edge of the sidewalk farthest away from the street and parallel to the street. b. Parking facilities shall not exceed 60 percent of the area between the property line and required setback on all street frontages. 4. Roof Design Roofs and rooflines can add character and interest to a home. Details on a roof are important as they break up the mass and perceived bulk. a. A minimum roof pitch of 4:12 applies to gable and hip roofs, unless other approved by the Zoning Administrator. This does not apply to portions of a roof that are separate from the structure’s primary roof. b. Flat roofs shall be screened by a parapet wall that is capped by a three-dimensional cornice treatment. c. Architectural styles that incorporate eaves shall have the eaves extend from the building wall at least 12 inches, as measured horizontally, on all façades. The Zoning Administrator may approve a shorter distance for roofs with a pitch of 12:12 or greater. d. The use of proportionally designed dormers on the roof is encouraged where they are appropriate to the architectural style of the home. 5. Anti-Monotony Standards for Townhouses Variation in front elevations adds character and interest to communities. In order to avoid monotony, different floor plans and façade treatments should be utilized to give residences their own identity. While some common elements may be shared, aspects such as color, material, detailing, and landscaping can be used to differentiate homes. Compliance with the requirements listed below shall be reviewed as part of a required site plan before any building permit application is submitted. Townhouses shall incorporate variation to any façade of a building that faces a public road or private road by utilizing the following elements. a. Variation in Building/Garage Placement The façade shall satisfy at least one of the following: (i) After at least every 30 feet [image omitted; see the official code] of frontage, all façades shall incorporate wall offsets that have a differential in horizontal plane of at least two feet. The wall offsets may be in the form of projections or recesses. An offset is also Figure 5.16 Variation in townhouse façades. required whenever there is a change in building material. (ii) For at least 25 percent of the dwelling units, garages shall be oriented either to the side or to rear of the building. b. Roof Variation The façade shall satisfy at least one of the following: (i) Changes in the roofline at intervals not exceeding 40 continuous feet in length, such as variations in roof pitch, overhangs, projections, exaggerated cornices, dormers, vegetated terraces, trellises, and extended eaves. (ii) The gross floor area of upper story is smaller than the gross floor area of the lower story. c. Architectural Design Features The façade shall satisfy at least one of the following: (i) Distinctive window patterns that are not repeated within groupings of up to four dwelling units. (ii) Balconies, bays, box-outs, faux balconies, window overhangs, or secondary roof eaves with exaggerated projections and decorative supporting rafter beams. (iii) Other architectural elements that the Zoning Administrator determines accomplish the objective of visually dividing the structure into smaller identifiable sections. 5.5.4. STANDARDS FOR MULTI-FAMILY RESIDENTIAL DWELLINGS A. Purpose The purpose of these standards is to improve the appearance and functionality of multi-family development, recognizing the importance of design in the economic success of urban areas, the need to be more efficient in the use of land, and the need to ensure the adequate protection of the surrounding area. These standards also are intended to: 1. Provide a distinctive architectural character in new multi-family residential developments that avoids featureless design, large building masses, and repetition of façades within a single development; 2. Promote sensitive design and planning of multi-family housing units that preserves or improves the characteristics of surrounding development; 3. Promote building design, placement, and orientation that contributes to a sense of neighborhood and community; and 4. Improve the quality of life of residents of multi-family residential dwellings. B. Applicability 1. These standards are applicable to new construction or redevelopment of multi-family dwelling units and independent senior living facilities in all zoning districts, except the following: a. Planned Development districts that have specific design standards; b. Landmark Preservation (LPO) Overlay District; c. Conservation District overlays that have specific design standards; and d. Form-based zoning districts. 2. This section is subject to the applicability standards of Section 5.1, Applicability of this Article. 3. Multi-family residential development located within a non-residential zoning district must also comply with all alternative design standards contained in Section 5.12, Standards for Multi-Family Residential Dwellings in Non- Residential Zoning Districts. In the event of a conflict between the standards contained in Section 5.12 and the requirements of this section, the alternative design standards shall control. C. Site Design and Building Organization 1. Access a. New multi-family developments with 100 or more units shall take primary access from an arterial street and shall comply with the following standards: (i) A minimum of one secondary point of ingress/egress into a multi-family development may be required for public safety access. (ii) No vehicular access from a multi-family development shall be provided on a local street serving existing single-family detached development; however, secondary vehicle access for public safety vehicles may be provided onto local streets. b. New multi-family development with fewer than 100 units may take primary access from a major collector street, if approved by the Zoning Administrator. c. See Section 5.2.2.B.6, Landscape at Site Entries for Multi-Family Developments for site entry landscaping standards. 2. Building Orientation and Common Open Space Common open space shall be provided in accordance with Section 5.10, Common Open Space, and this section. a. Large open space should be the fundamental organizing element of the site. Common open space should be well defined by buildings and streets. Buildings should be oriented in such a way as to create courtyards and open space areas. b. Large existing trees and other natural features should be integrated into the open space. c. Common open space should be centralized and directly accessible to a majority of the surrounding units. Where possible, it should be linked to adjacent parks, paths, and open space areas. d. The open space shall be useable areas and not riparian areas or slopes exceeding 3:1. 3. Site Amenities In conjunction with the common open space requirements, all multifamily projects shall provide two or more site amenities listed below for the residents. For the reduction in minimum unit size, allowed in DB and DNO, the project shall provide three or more site amenities. Amenities must be centrally located for a majority of the residents and may be located within the common open space areas. a. Swimming pool. b. Sports courts, such as tennis, basketball, or volleyball. c. Natural open space area with benches. d. Jogging trails. e. Fountains, art, or sculpture. f. Other amenity as approved by the Zoning Administrator. D. Building Separation For Multi-Family Development 1. Separation Required a. In any district in which multi-family dwellings are permitted by this Code, the minimum spacing between buildings with walls that have openings for doors and windows on façades facing each other shall be as indicated in Table 5.5-1, below. TABLE 5.5-1: Required Separation for Multi-family Development Building Orientation | Minimum Separation (feet) Face to Face | 50 Face to End | 30 Corner to Face or End | 30 End to End | 30 b. From building to building with walls that do not have openings, the minimum distance between buildings is 20 feet for one- and two-story buildings and 30 feet for three-story or taller buildings. c. The minimum distance between buildings and freestanding garage buildings is 30 feet. d. For purposes of measurement in this subsection, projections such as decks and bay windows shall not be counted. [image omitted; see the official code] Figure 5.17 Description of separation requirements for multi-family buildings. Graphic is not intended to show a proposed layout of a multi-family development. E. Off-Street Parking Location a. At least half of the required number of parking spaces shall be provided in a parking structure, enclosed garage, or carport. At least 20 percent of the required number of parking spaces shall be located in an enclosed garage. b. Parking areas or surface parking shall not be located between any building and the adjacent street, except for parking for the leasing office. c. Garage entries, carports, parking areas, and parking structures shall be internalized in building groupings or oriented away from the street frontages. d. Parking areas and freestanding parking structures (detached garages or carports) shall not occupy more than 25 percent of each perimeter public street frontage. Driveways and associated driving areas shall be included in calculating this percentage. e. Surface parking areas shall be configured into subgroupings of 80 or fewer spaces to the maximum extent practicable as a means of dispersing parking across the site. f. To the maximum extent practicable, freestanding parking structures that are visible from perimeter public streets shall be sited so that the narrow end of the parking structure is perpendicular to the perimeter street. Parking structures shall comply with applicable requirements of Section 5.4.9.I, Parking Structures. g. In addition to the general requirements in Section 5.2.2.E, Parking Lot Landscaping and Screening, the following requirements shall apply: (i) All surface parking shall be separated from any building by a landscaped strip of at least ten feet in width that includes a five-foot wide sidewalk, if required [image omitted; see the official code] by the standards in Section 5.9.4, Pedestrian Circulation. (ii) Double rows of parking shall be separated by a landscaped median of at least eight feet in width. The median may be curbless if wheelstops are provided in the parking spaces. Figure 5.18 Curbless median with wheelstops F. Building Design 1. 360-Degree Architecture All sides of a multi-family building shall display a similar level of quality and architectural detailing as on the front elevation. 2. Building Mass and Articulation a. Each elevation greater than 30 feet in length, measured horizontally, shall incorporate wall plane projections or recesses having a depth of at least 10 percent of the length of the [image omitted; see the official code] façade, and extending at least 20 percent of the length of the façade. b. The elevations of all multi-family buildings shall be articulated through the incorporation of at least six or more of the following: (i) Balconies, a minimum of 25 square feet in area; Figure 5.19 Multi-family structure with multiple design elements (ii) Bay or box windows; (iii) Porches or covered entries that are proportional to the size of the building; (iv) Dormers; (v) Awnings or canopies; (vi) Structural offsets a minimum of four feet from the principal plane of the façade; [image omitted; see the official code] (vii) Accent materials such as brick, stone, or stucco with banding highlights; (viii) Ornamental or decorative window grills and shutters; (ix) Variation in window sizes and shapes; Figure 5.20 Vertical building elements and (x) Vertical elements such as modules towers or building end-caps that demarcate building modules; or (xi) Other features as approved by the Zoning Administrator. c. The height of any part of a multi-family building shall not exceed 40 feet if the building is located within 50 feet of a property zoned or used for single-family residential. Buildings and parts buildings located more than 50 feet away are not subject to height restrictions. d. Multi-family buildings shall provide concentrated unit access points. Monotonous access balconies and corridors running the length of the exterior of a building are prohibited. 3. Roof Form a. Multi-family residential buildings shall be designed to avoid any continuous roofline longer than 50 feet. Rooflines longer than 50 feet shall include at least one vertical elevation change of at least two feet. b. The incorporation of a variety of roof forms is strongly encouraged. Upper-level residential floors may be incorporated into the roof form to reduce the apparent height and mass of buildings. 4. Vertical Articulation a. The top floor of any building shall contain a distinctive finish, consisting of a cornice, banding, or other architectural termination. b. For all structures three stories or more in height, the base (first 20 feet) of a building shall be distinguished from the remainder of the building by providing a minimum of three of the design elements listed above in subsection 5.5.F.2.b, above. c. Multi-family buildings shall be designed to incorporate visually heavier and more massive elements at the building base, and lighter elements above the base. Upper stories shall not appear heavier or demonstrate greater mass than the lower stories of the building. [image omitted; see the official code] Figure 5.21 Base identified by design elements. 5. Building Length The maximum length of any multi-family building shall be 180 feet. 6. Entry Design a. To the maximum extent practicable, the primary entrance and façade of individual buildings within a residential development shall not be oriented towards parking, but shall be oriented towards: (i) An abutting public street, or (ii) Common open space, such as interior courtyards, parks, or on-site natural areas, or features with a clearly defined and easily accessible pedestrian circulation system. b. Ground-floor units with frontage along the primary street shall have an entrance that faces the street. Multi-family buildings located with multiple street frontages shall provide entrances to units along each street frontage. (i) Dwelling units above the [image omitted; see the official code] ground floor shall have interior unit entrances, except that exterior stairs are permitted for access to upper-floor units only if they are oriented towards a central plaza not visible from any street. c. Stairwells and stairways shall be Figure 5.22 Exterior stairs not visible integrated into the design of the building. 7. Transparency At least 25 percent of all walls facing a public street shall contain windows or doorways. 8. Design of Multiple Buildings a. Developments with more than one multi-family building shall incorporate a variety of distinct building designs according to the scale of the development, as follows: (i) 2-6 buildings: two models minimum; (ii) 7-12 buildings: three models minimum; and (iii) 13 or more buildings: one model per four buildings or portion thereof minimum. b. Distinct building designs, as required above, shall be easily distinguished through a minimum of two of the following: (i) A variation in length of 30 percent or more; (ii) A variation in the footprint of the building of 30 percent or more; (iii) A distinct variation in color and use of materials; (iv) A variation in the type of dwelling unit contained in the building that results in a significantly different scale and mass, i.e., apartments vs. townhomes or duplexes; or (v) A distinct variation in building height and roof form. 9. Garages and Carports [image omitted; see the official code] a. All garages and carports shall be located at the rear or side of the primary structure. Garages may be integrated into the building with the units. b. All carports and garages shall be designed as an integral part of the architecture of the project. Garages and carports shall be constructed with compatible Figure 5.23 Garages integrated into building. architectural treatments that [image omitted; see the official code] match the main buildings (e.g., roof pitch, gable type and orientation, roof materials). Support columns for carports shall include a compatible masonry base. c. Any enclosed parking structure shall be designed so that the only Figure 5.24 Compatible carport design openings at street level are for auto or pedestrian circulation. The remaining street wall of the ground floor shall be wrapped by units or include façade treatments such as projections, recesses, niches, fenestration, or changes of materials or color. 10. Defensible Space a. Crime Prevention Through Environmental Design (CPTED) best practices, including providing defensible space, opportunities for natural surveillance, territorial reinforcement, and access control, should be incorporated into site, building, and unit design. b. The concept of private space and control of access points should be reinforced using low fences and landscaping, as appropriate. c. Window placement between units should balance privacy and natural surveillance. 11. Trash and Storage Areas a. In addition to the requirements of Section 5.3.3.E Refuse Facility Screened, the standards in this section shall apply. b. Trash enclosures shall be [image omitted; see the official code] internalized and oriented away from streets and residential areas. Enclosures should be located inside parking areas or at the end of parking bays. Enclosures should not be located adjacent to primary buildings. c. Trash enclosures should be placed in locations for tenant Figure 5.25 Trash enclosure with compatible convenience and pickup service. architectural design d. Enclosures shall be architecturally compatible in design to the primary buildings on site using common colors, building materials, and roof materials. 12. Mailrooms and Other Accessory Structures a. Mailrooms or mail kiosks may be incorporated into another building or separated from all other buildings by a minimum of 20 feet. b. All mailrooms or accessory structures shall be architecturally compatible in design to the primary buildings on site using common colors, building materials, and roof materials. 13. Minimum Dwelling Unit Sizes Minimum dwelling sizes must comply with Section 5.5.2.C, Multi-Family and Mixed-Use Residential Dwelling Unit Sizes. G. Building Materials 1. Exterior Wall Materials a. A minimum of two distinct building materials from the preferred material list shall be utilized on all façades to provide architectural detail and interest. b. For purposes of this section, preferred materials shall be defined as: (i) Stone or brick laid up unit by unit [image omitted; see the official code] and set in mortar; (ii) Exterior portland cement plaster (stucco) with three coats over metal lath or wire fabric lath; (iii) Cultured stone, cast stone, or natural stone panels; (iv) Architecturally finished block (i.e. burnished block or split faced Figure 5.26 Multiple materials on façade concrete masonry units), only up to 4 feet above the foundation or surrounding grade; (v) Exterior Insulation and Finish System (EIFS), but only for trim and eaves; (vi) Cementitious fiberboard siding, provided that: (1) It may only be used on multi-family structures that are three stories or less in height, and (2) Each side of a structure may contain a maximum coverage of 50 percent cementitious fiberboard siding; (vii) Metal cladding; or (viii) Other material deemed appropriate for the architectural style, as approved by the Zoning Administrator. (ix) The use of wood for trim, accents, or soffits, may be permitted if approved by the Zoning Administrator. 2. Roofing Design and Materials a. Asphalt shingles, composite or synthetic shingles, standing-seam metal, or tile roofs are allowed. b. Pitched roofs, if provided, shall have a minimum pitch of 6:12 on single-story or two-story buildings, and a minimum pitch of 4:12 on buildings three-stories or taller. c. Other roof types shall be appropriate to the architectural style of the building. d. Architectural elements that add visual interest to the roof, such as dormers and masonry chimneys are encouraged. e. Flat roofs shall require parapet screening. Parapets shall be constructed of the same material as the primary façade. 3. Awnings and Overhanging Eaves Awnings and overhanging eaves may be constructed of industry-accepted metal, canvas, and woven vinyl. 4. Retaining Walls A retaining wall that is three feet in height or taller and that is not part of an improved drainage channel shall be constructed of masonry, stained concrete, or textured concrete. 5.5.5. RESIDENTIAL DESIGN STANDARDS FOR VILLAGE ON THE GREEN AT TIERRA VERDE A. Compliance with Residential Design Standards Residential development in the VG district shall comply with Section 5.5.3, Standards for Single-Family and Two-Family Residential Dwellings, except as otherwise specified in this section. 1. Garage Location Front loading, front facing garages are prohibited in the VG district. However, a separate front facing, front loading garage for a third bay is permitted provided: a. The dwelling has a J-swing garage that provides parking for two vehicles; and b. The front of the separate third bay is set back at least 40 feet from the front property line and at least 20 feet from the front building façade. B. Dimensional Standards Development in the VG district shall meet the dimensional requirements of Table 5.5- 2, VG Minimum Contiguous Acreage and Dwelling Unit Size, and Table 5.5-3, VG Dimensional Standards. The measurement of minimum contiguous acreage shall be based on the approved preliminary plat of the development. | TABLE 5.5-2: VG Minimum Contiguous Acreage and Dwelling Unit Size | Number of Units per Acre | | | 4.5 | | | 3.5 | | | 2.5 | | | 1.5 | | | 1.0 | | | 0.5 Minimum Contiguous Acreage | 20 or more | 10 to 19 | | N/A | | | N/A | | | N/A | | | N/A Minimum Dwelling Unit Size (sq. ft.) | 2,250 | 2,500 | 2,750 | 2,750 | | N/A | | | N/A TABLE 5.5-3: VG Dimensional Standards A. Lot Dimensions 1. Lot area, min. (s.f.) Single family | 7,200 Non-residential | 15,000 2. Lot width, min. (ft) Single family | N/A Non-residential | N/A 3. Lot depth, min. (ft) | N/A B. Setbacks 4. Street front, min. (ft) All roadways | 20 Alley, or private access easement | 20 5. Street side, min. (ft) All roadways 5 Alley, or private access easement 5 6. Street rear, min. (ft) All roadways 5 Private access easement or alley 5 7. Interior, min. (ft) Side 5 Rear 5 [image omitted; see the official code] Non-residential adjacent to single family 30 (side and/or rear) C. Building Standards Building height, max. 40 Lot coverage, max. (%) Single family 40 Non-residential 40 See Article 4 for measurements and exceptions. C. Open Space 1. Common open space for public congregation and recreational opportunities are required for all residential subdivisions of 10 or more lots. All residential subdivisions must provide open space and trails according to the table below: TABLE 5.5-4: VG Open Space Requirements Number of Units per Acre | 4.5 | 3.5 2.5 | 1.5 | | 1.0 | .5 Common Open Space % Required | 20 | 20 10 | 10 | | 10 | 10 Contiguous Common Open Space % Required (private property) | 15 | 15 5 | 5 | | 5 | 5 Contiguous Common Open Space % Required (Tierra Verde Golf Club) | 15 | 15 5 | 5 | | 5 | 5 Trail Construction Trail Construction or Connection to Master Trail | | Required If Trail Connection to Master Trail, then | | 5% decrease in open space Park Fees Park Fee Waiver Eligibility | NA | 25% 50% | 50% | | 100% | 100% [image omitted; see the official code] [image omitted; see the official code] [image omitted; see the official code] 2. Any development on land adjacent to the Tierra Verde Golf Club must provide required open space adjacent to the golf club. a. Fencing of adjacent and/or contiguous properties shall consist of brick or wrought iron fence materials. b. All developments adjacent and/or contiguous with public park property shall construct their portion of the trail system per Parks and Recreation Department trail standards and the Arlington Hike and Bike System Master Plan. c. A reduction in open space requirements shall be allowed for open space contiguous to adjacent open space as designated by platting or adjacent to public property. d. No common open space less than one-half (0.5) acre shall be counted towards open space credit. e. Common open space shall be located behind any maximum setbacks and on private property. f. Common open space shall be maintained by a private homeowners association or may be considered for dedication to the City. D. Perimeter Streetscape Buffer Requirements 1. In order to maintain a rural character in the VG district, a perimeter streetscape buffer shall be required in accordance with the following table: TABLE 5.5-5: VG Streetscape Requirements No. Units/Acre | 4.5 | 3.5 | 2.5 | 1.5 | 1.0 | 0.5 Perimeter Streetscape Buffer (ft) All frontage along minor and major collectors and all arterials, including right-of-way. | 30* 30* 20 20 20 20 Perimeter Street Trees | Required 1 per 30 feet linear frontage Entry Features (landscaping and signage) | Required [image omitted; see the official code] Notes: *This setback may be reduced to no less than 20 feet due to design considerations with approval from the Zoning Administrator. 2. The perimeter streetscape buffer shall be identified as open space lots on the plat. The open space lot shall be owned and maintained by a homeowners association. 3. All required screening fences shall be constructed of a combination of decorative wrought iron and masonry columns with landscaping or split rail fencing and landscaping. 4. The species of perimeter street trees is subject to approval by the Zoning Administrator. E. Street Design TABLE 5.5-6: VG Street Design No. Units/ Acre | 4.5 | 3.5 | 2.5 | 1.5 | 1.0 | 0.5 Street Design | Standard Rural Standards May Apply Sidewalk Widths | Standard Rural Standards May Apply Curvilinear Street Design | Required 5.5.6. RESIDENTIAL DESIGN STANDARDS FOR SMALL LOT DEVELOPMENT ON UNPLATTED RESIDENTIAL-ZONED TRACTS OF 5 ACRES OR MORE A. Purpose The purpose of these standards is to establish consistent development standards for residential lots as small as 3,000 square feet and to improve the appearance and functionality of small-lot development. These standards are intended to: 1. Promote housing diversity while being sensitive to the characteristics of surrounding developments; 2. Ensuring new development contributes to a well-planned, livable community; 3. Promote common open spaces and amenities that contribute to a sense of neighborhood and provide a better quality of life for the residents; 4. Complement or be compatible with the surrounding uses and community facilities; 5. Contribute to, enhances, or promote the welfare of the area and adjacent properties; and 6. Advance the goals of adopted neighborhood or area plans, ensuring the proposed development contributes to cohesive community design, preserves natural features where appropriate, and reinforces connectivity and walkability. B. Applicability 1. These standards are applicable to new construction or development of small-lot developments within: a. An unplatted tract of land of 5 acres or more located in an area zoned for single-family homes; b. Has no recorded plat; and c. Is not within 3,000 feet of an airport. 2. Such small-lot residential development shall comply with Section 5.5.3, Standards for Single-Family and Two-Family Residential Dwellings and Section 5.5.5, Residential Design Standards for Village on the Green at Tiera Verde if located within the VG zoning district, except as otherwise specified in this section. 3. In the event of a conflict between the requirements of this section and any other sections of the UDC, these standards shall control. C. Site Design 1. Access and Subdivision Regulations a. For adequate access requirements, refer to Section 6.4.4., Requirement for Access to the Street Network. b. Also, refer to Article 6, Subdivisions Regulations and Infrastructure Adequacy Requirements, for regulations related to the design of infrastructure and the subdivision plat. 2. Tree Preservation a. Tree Preservation standards must comply with Section 5.2.3 Tree Preservation and Replacement of this code. 3. Common Open Space and Amenity Requirements a. Such developments shall be required to preserve 35 percent of the site’s gross area for common open space. (Tree preservation area may be counted towards common open space). b. In addition, such developments shall be required to provide 15 percent of the site’s gross area as usable open space. This percentage may count toward the 35 percent open space requirement. b. In the VG zoning district, such developments shall require perimeter streetscape buffer of 50 feet with landscaped curvilinear berms. This area could be counted towards common open space requirement. c. Such developments with more than 40 single-family lots shall be required to provide an amenity center and a pool. d. The open space and amenity spaces shall be owned and maintained by a homeowners association. 4. Screening and Buffering, and Fences a. For privacy fences, perimeter screening fence and buffers, standards must comply with Section 5.3, Screening, Buffering, and Fences, except for perimeter standards in the VG zoning district, refer to Section 5.5.5. Residential Design Standards for Village on the Green at Tierra Verde. 5. Block Requirements a. Maximum block length shall be 300 feet. b. In a block length of 300 feet, provide at least one mid-block open space. The mid-block access shall be a minimum of 30 feet in width and run the entire depth of the block and connect two streets or serve as a connection to a park, open space lot, school, trail, or recreation or amenity area for public use or for use by residents of the subdivision. The access may be provided as an open space lot or easement. c. Open space, larger than required mid-block open space, shall be required at approximately every 800 feet. Also, refer to Section 5.10 Common Open Space for other requirements and Section 5.5.5 Residential Design Standards for Village on the Green at Tierra Verde. 6. Subdivision Entry Design a. The main site entry for small-lot developments shall be treated with special landscape elements that will provide an individual identity to the project. b. Site entry and main access drives for small-lot development, with more than 20 lots shall include at least three (and with 20 lots or less shall include at least two) of the following: (i) a minimum 5-foot wide landscaped median; (ii) textured paving, interlocking pavers, or other decorative pavement; (iii) gateway elements such as lighting, bollards, entry fences, or monuments; (iv) a roundabout containing landscaping, water feature, or artwork; (v) other improvements as approved by the Zoning Administrator. 7. Other Requirements a. Vehicular access is required to be from the rear of the lots via alleys/private access easements. b. The lots may front a street or a paseo. c. The fronting streets shall comply with City standard of a local street with a minimum of 28-foot wide pavement width. The internal streetscape standard shall include a minimum five-foot-wide sidewalk with a minimum four-foot-wide buffer area between the street and the sidewalk. d. If they front a paseo, it shall be minimum 30 feet wide, consisting of a meandering sidewalk of a minimum 8-foot width and enhanced landscaping or tree preservation clusters. e. If the lots are fronting a paseo, an additional parking is required at the site entrance for shared rides and delivery, as well as at least 10 visitor parking spaces close to the amenity areas within the site. f. To enhance visual interest and reinforce a sense of place, a vista terminus shall be incorporated at the end of every street or primary view corridor within the development. It must contain a prominent architectural, landscape, or public art feature, inclusive of a visually appealing house or formal green space or tree cluster with some feature. The feature should be scaled appropriately to its context and aligned to reinforce axial views and pedestrian orientation. D. Lot Design 1. Dimensional Standards The development shall meet the dimensional requirements of Table 5.5-7: Small-Lot Dimensional Standards. TABLE 5.5-7: Small-Lot Dimension Standards A. Lot Dimensions 1. Lot area, min. (square feet) Single family, detached 3,000 Townhouse 2,900 2. Lot width, min. (feet) Single family, detached 30 Townhouse 25 3. Lot depth, min. (feet) 75 B. Setbacks 4. Street front, min. (feet) All roadways 15 Alley or access easement 15 5. Street side, min. (feet) All roadways 50 Alley or access easement 5 6. Street rear, min. (feet) All roadways 10 Alley or access easement 10 7. Interior, min. (feet) Side 50 Rear 10 C. Building Standards 3 stories (10 feet in height Building height, measured from interior max: floor to ceiling) Lot coverage, 70 max (%) See Article 4 for measurements and exceptions. 2. Minimum Living Unit Area Refer to the base zoning districts in Section 2.2, Residential Districts, for the applicable Minimum Living Unit Area requirement. 3. Parking Requirements and Location a. Garages, carports, or driveways shall not be allowed in front of the house; instead, the units shall have a minimum of 60 square feet front porch, or a combination of front porch and balcony to be at least 60 square feet in size. b. Garages/carports shall only be alley-loaded. c. For lot sizes between 3,000 square feet and 4,000 square feet, a minimum of one parking space per unit is required. d. For lot sizes greater than 4,000 square feet and less than 5,000 square feet, a minimum of one enclosed garage and one driveway space per unit is required. e. All other parking requirements must comply with Section 5.4.9 of this code. 4. Landscaping a. The front yards shall include at least one shade tree, unless fronting a paseo that has tree preservation cluster or new shade trees planted. b. All other landscaping standards shall comply with the Section 5.2.2.A Residential Landscaping of this code. E. Building Design 1. Building Design Standards must comply with Section 5.5.2, General Standards for all Residential Development, Section 5.5.3, Standards for Single-Family and Two-Family Residential Dwellings, and Section 5.8.7, Village on the Green at Tierra Verde for VG building standards. 2. Require meandering sidewalks in paseos that might help in creating architectural offsets in the building facades every block. 3. Incentives to promote anti-monotony and a mix of housing types Variation in lot sizes (and house sizes) make a residential neighborhood diverse. A diverse neighborhood would accommodate homes for families of all sizes and life-stages. a. Allow duplexes on minimum 5,000 square feet and 50-foot lot width. Stacked duplexes are allowed but the duplexes cannot exceed 30 percent of the housing types or more than 30 percent of a block face. b. Building height variation (number of stories variation after every few lots on the block) and wall articulation (front building façade offsets every few lots) are encouraged in every block, that may allow incentives towards reduction in tree preservation requirement up to 10 percent of the required 35 percent tree preservation.

Amended by Ord. No. 26-019, passed 4-21-2026.

Ask a question about Arlington law

Corpus searches the Arlington sections it holds and shows the ones that match, with their citations. Free, no sign-in.