§ 5.7 — Mixed-Use Design Standards
Code of the City of Arlington, Texas (City Secretary chapter PDFs as posted 2026-11-07, each current through the ordinance named on its cover, with the City Secretary's adopted-not-yet-codified Ordinances 25-063, 25-069, 25-073, 25-074, 25-075, 25-084, 26-003, 26-004, 26-019, 26-024 and 26-027 applied; Anti-Discrimination chapter not included) · Arlington City Code, Unified Development Code Chapter, § 5.7
Corpus is an independent public-information project, not the official City of Arlington website. Stable reference: corpuslaw.us/code/e7b22dcc-26f7-46bc-b632-d847a0b3a951
5.7. MIXED-USE DESIGN STANDARDS
5.7.1. PURPOSE These standards are intended to promote compact, pedestrian-friendly, and transit-supportive patterns of development in mixed-use areas of the city; to guide the organization of mixed-use development in a variety of contexts; and to minimize the visual effects of parking within mixed-use areas. These standards are supplemental to the non-residential design standards and are intended to promote distinct design and sense of place that strengthen mixed-use areas as signature developments. 5.7.2. APPLICABILITY A mixed-use development in the NMU, RMU, LCMUO, or EDO district that is subject to Article 5 based on Section 5.1, Applicability, shall also comply with the non-residential development and design standards in Section 5.6, Non-Residential Design Standards and the standards of this section. In the event of conflict, the standards of this section shall control. 5.7.3. USES The following standards shall apply within the mixed-use districts: A. Mix of Uses To provide for a balance of commercial, office, residential, and civic uses, new developments in the mixed-use districts shall include a mix of two or more distinct types of permitted uses. B. Required Mix of Uses—Sites 50,000 Square Feet or Larger All developments on sites that exceed 50,000 square feet of gross floor area shall include at least one use from the Commercial Uses category, as identified in Table 3.1-2, Allowed Uses – Non-Residential and Mixed-Use Districts. C. Ground-Floor Uses The incorporation of retail shops and/or restaurants is encouraged at the street level to promote a more active environment for pedestrians and to support residential and office uses located within the same building (on upper floors) or nearby. This configuration of uses is particularly encouraged along major street frontages as well as adjacent to major public spaces, where a high level of activity and visibility is desirable. If a limited portion of a structure’s ground level will be devoted to retail or restaurant space, such space should be located along those façades adjacent to or most visible from primary street frontages or major pedestrian walkways. 5.7.4. SITE DESIGN AND BUILDING ORGANIZATION A. Minimum Development Street Frontage/ Build-to-Line A minimum of 60 percent of each development’s total building street frontage along a major arterial shall be located at the minimum front setback line for that district. The remaining 40 percent may be set back farther. This percentage may be changed for infill or redevelopment where existing, measurable standards differ from this requirement. In those locations, the new structure shall have a street face in keeping with the context of surrounding structures. B. Architectural Setback Encroachments Any architectural feature may encroach up to five feet from the building face into the setback area, unless otherwise approved by the Zoning Administrator, and provided such feature is compatible with the architectural style of the building. No poles or supporting columns are permitted in the street right-of-way. These features may include, but are not limited to: 1. Stairs, stoops, and porches; 2. Chimneys; 3. Awnings and overhangs, which shall provide a minimum of nine feet of clearance above grade; 4. Canopies; 5. Eaves; 6. Tower elements; 7. Pilasters; 8. Bay windows, which shall provide a minimum of 10 feet of clearance above grade and may be no more than 10 feet in width; 9. Mounted signs; or 10. Balconies, which may have roofs but are required to be open and provide a minimum of 10 feet of clearance above grade. C. Streetfront Building Setbacks Setback areas are intended to be occupied by sidewalks, landscaping, outdoor dining areas, street amenities, kiosks, and other similar permitted uses and structures. Surface parking lots, off-street parking spaces, and associated driving aisles shall not be permitted between the building and street. D. Throughway Zone At all times, the throughway zone shall remain clear of any obstructions. E. Building Corner Treatments Buildings shall be designed to reinforce a strong corner condition at street intersections in order to emphasize a “street wall,” in which block closure along the street edge is a definitive characteristic of the development. Buildings shall also be designed to accommodate required visibility triangles without compromising the corner design. [image omitted; see the official code] Figure 5.39 Acceptable building corner treatments. 5.7.5. BUILDING DESIGN A. Maximum Building Length Buildings shall not exceed 250 feet in length without an unconnected physical separation of at least 15 feet between another building. This separation shall mark the location of a small pedestrian walkway, allowing a walkable connection to residential and parking areas behind commercial and retail mixed-use frontage buildings. In areas where shorter building lengths are common, a new structure shall match the average building length of the adjacent two structures. If an adjacent lot is empty, the average shall be created based on the closest three buildings on the same street face. 1. The pedestrian walkway shall be lighted and designed to be safe and visually interesting for pedestrians. 2. The pedestrian walkway shall be designed so that it cannot be closed or locked. 3. The pedestrian walkway shall be designed to connect separate buildings or link to customer parking. B. Building Height To ensure a minimum level of street-wall volume consistency, all buildings shall have a minimum height of 20 feet measured above finished grade to the top of roof structure. C. Mixed-Use Residential Entry Features All units with frontage along the primary street shall have an entrance that faces the street. Mixed-use buildings with multiple street frontages shall provide entrances to units along each street frontage. 1. Exterior entrances from a public sidewalk or common open space are permitted for dwelling units on the ground floor. These entrances shall be raised from the finished ground-floor level of the sidewalk a minimum of two feet. 2. Dwelling units above the ground floor shall have interior unit entrances, except that exterior stairs are permitted for access to upper-floor units only if they are oriented towards a central plaza not visible from any street. D. Transparency 1. At least 40 percent of any ground-floor wall that faces or is visible from a public street, a right-of-way, or a park shall contain display areas, windows, or doorways. Windows shall be unobstructed and allow views into working areas or lobbies, pedestrian entrances, or display areas. Blank walls are prohibited. 2. At least 20 percent of walls above 20 feet that face a public street shall contain windows. 5.7.6. DEVELOPMENT PLANS REQUIRED FOR ALL MIXED-USE DEVELOPMENT All mixed-use developments in the NMU, RMU, LCMUO, and EDO districts shall require approval of a Mixed-Use Development Plan in accordance with Section 10.4.5A.
Amended by Ord. No. 26-019, passed 4-21-2026.
Ask a question about Arlington law
Corpus searches the Arlington sections it holds and shows the ones that match, with their citations. Free, no sign-in.