For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 51.60 — Definitions

Code of Ordinances of the City of Garland, Texas (Garland Code of Ordinances, Home Rule Charter and Garland Development Code current through Ordinance 7697 adopted August 17, 2026 (eCode360 publication GA6318, scraped 2026-11-17)) · Garland Code of Ordinances § 51.60

Corpus is an independent public-information project, not the official City of Garland website. Stable reference: corpuslaw.us/code/6a6d1919-1479-4d77-b74c-16e606f01478

§ 51.60: Definitions.

For the purpose of this article, the following definitions shall apply unless the context clearly indicates or requires a different meaning. If a word or term used in this article is not contained in the following list, its definition, or other technical terms used, shall have the meanings or definitions listed in the most recent edition of the Manual of Cross-Connection Control published by the Foundation for Cross-Connection Control and Hydraulic Research, University of Southern California. Air gap. A physical separation between the free flowing discharge end of a potable water supply piping or appurtenance and an open or non-pressure receiving vessel, plumbing fixture or other device. An approved air-gap separation shall be at least twice the diameter of the supply pipe measured vertically above the overflow rim of the vessel, plumbing fixture or other device in no case less than one inch. Approved fire sprinkler contractor. A person or entity holding a certificate of registration as such issued by the Texas State Fire Marshal’s Office. Atmospheric vacuum breaker backfiow prevention device or atmospheric vacuum breaker or AVB. A device used to prevent backsiphonage in non-health hazard conditions. This device cannot be tested and cannot prevent backpressure backflow. Approved backflow prevention assembly or backflow assembly or assembly. An assembly to prevent backpressures or prevent backsiphonage and which is listed as an approved assembly by the University of Southern California (USC) Foundation for Cross-Connection Control and Hydraulic Research or similar rating or standards organization recognized by the Managing Director. Backflow. A flow in a direction opposite to the normal flow or the introduction of any foreign liquids, gases, or substances into the public water system. Boresight or boresight to daylight. Providing adequate drainage for backflow prevention assemblies installed in vaults through the use of an unobstructed drain pipe. Contamination or contaminate. The entry into or presence in a public water supply system of any substance which may be harmful to health or to the quality of the water. Cross-connection. Any physical arrangement where a potable water supply is connected, directly or indirectly (actually or potentially), to or with any non-potable water system or source, used water system or auxiliary water supply, sewer, drain conduit, swimming pool, storage reservoir, plumbing fixture, evaporative coolers, air conditioner units, fire protection system, or any other assembly which contains, or may contain, contaminated water, sewage, or other liquid of unknown or unsafe quality which may be capable of imparting contamination to the public water system as a result of backflow. Bypass arrangements, jumper connections, removable sections, swivel or change-over assemblies, or other temporary or permanent assemblies through which, or because of which, backflow may occur are considered to be cross-connections. Customer service inspection. An inspection designed to inspect and detect any actual or potential cross-connection hazards and/or exceedence of the lead content levels in solder or flux, pipe or pipe fittings. Degree of hazard. The hazard classification (low or high) assigned to an actual or potential cross-connection. Double check detector backflow prevention assembly or double check detector or DCDA. An assembly composed of a line-size approved double check assembly with bypass containing a specific water meter and an approved double check valve assembly. The meter shall register accurately for very low rates of flow. Double check valve backflow prevention assembly or double check assembly or double check. An assembly which consists of two independently operating check valves which are spring-loaded or weighted, a gate valve on each side of the checks, and test cocks to test the checks for tightness. Fire line tester. A tester who is employed by an Approved Fire Sprinkler Contractor and is qualified to test backflow prevention assemblies on fire lines. General tester or tester. A tester who is qualified to test backflow prevention assemblies on any domestic, commercial, industrial or irrigation service except fire lines. Recognized backflow prevention assembly testers shall have completed a TCEQ Executive Director approved course on cross-connection control and backflow prevention assembly testing, pass an examination administered by the TCEQ Executive Director, and hold a current license as a backflow prevention assembly tester. Health hazard. A cross-connection or potential cross-connection involving any substance that could, if introduced into the potable water supply, cause death or illness, spread disease, or have a high probability of causing such effects. Inspector. A person who is recognized by the City of Garland as a licensed inspector under the provisions of this article. Non-health. The classification assigned to an actual or potential cross-connection that may allow contamination which may be objectionable but not hazardous to health to backflow into the public water system. Managing director. The Managing Director of Water and Wastewater Utilities or a person designated by the Managing Director or the City Manager. Multifamily residential use. Water used by any residential customer of the water supply and include duplexes, multiplex, housing and apartments where the individual units are each on a separate meter; or, in cases where two or more units are served by one meter, the units are full-time dwellings. Nonresidential use. Water used by any person other than a residential customer of the water supply and include all uses not specifically included in residential uses as defined in the City of Garland Comprehensive Zoning Ordinance. Pollution hazard. An actual or potential threat to the physical properties of the water system or the potability of the public or consumer’s potable water system or the consumer’s potable water system but which would not constitute a health hazard. Maximum degree of intensity of pollution which the potable water system could be degraded under this definition would cause a nuisance or be aesthetically objectionable or could cause damage to the system or its appurtenances. Potable water. Any water supply intended or used for human consumption or other domestic use. Premises. Any real property to which water is provided, including all improvements, buildings, mobile and other structures located on it. Premises containment. Backflow prevention at the service connection between the public water system and the water user. Premises isolation. Backflow prevention at the point of use internally on the customer’s premises. Public water system or system. Any public or privately owned water system which supplies water for public domestic use including all service lines, reservoirs, facilities, and any equipment used in the process of producing, treating, storing or conveying water for public consumption. Reduced pressure principle detector backflow prevention assembly or reduced pressure detector or RPDA. An assembly composed of a line-size approved reduced pressure principle assembly with a bypass containing a specific water meter and an approved reduced pressure principle backflow prevention assembly. The meter shall register accurately for very low rates of flow. Residential use. Water used by any residential customer of the water supply and include single-family dwellings. Reduced pressure principle backflow prevention assembly or reduced pressure principle assembly or RP assembly or RP. An assembly containing two independently acting approved check valves, a hydraulically-operated, mechanically independent pressure differential relief valve located between the check valves and at the same time below the first check valve, and including properly located test cocks and tightly closing shut-off valves at each end of the assembly. Service connection. The point of delivery at which the public water system connects to the private supply line or lateral of a water user. Spill-resistant pressure vacuum breaker or SVB. An assembly containing an independently operating, internally loaded check valve and independently operating, loaded air inlet valve located on the discharge side of the check valve. This assembly is to be equipped with a properly located resilient seated test cock and tightly closing resilient seated shutoff valves attached at each end of the assembly. Thermal expansion. The natural change in volume of a confined quantity of water as a result of the raising of the temperature of that water. TCEQ. Texas Commission on Environmental Quality. Used water. Water supplied by a public water system to a water user’s system after it has passed through the service connection. Water use survey. A survey conducted or caused to be conducted by the local authority designed to identify any possible source’s of contamination to the potable water supply.

( Ordinance 6393 , sec. 1, adopted 4/20/10 ; Ordinance 7396 adopted 1/17/2023 )

Ask a question about Garland law

Corpus searches the Garland sections it holds and shows the ones that match, with their citations. Free, no sign-in.