§ 51.76: Testing of assemblies.

(A) All multifamily residential use and nonresidential use backflow prevention assemblies shall be inspected and tested or caused to be inspected and tested by the City in each of the following circumstances: (1) Immediately after installation; (2) A minimum of once a year or as required by the Managing Director; (3) Immediately after repair; (4) When premises that have been vacated and unoccupied for one year, prior to re-occupancy; (5) Whenever the assembly is moved. (B) Duly authorized employees of the City bearing proper credentials and identification are entitled to enter any public or private property for the purpose of enforcing this article. Persons and occupants of the property which are provided water service by the City, either directly or indirectly, shall allow the City or its representatives ready access at all reasonable times to all parts of the property for the purpose of inspection, testing, records examination, or in the performance of their duties. When persons or occupants of the property have security measures in force which would require proper identification and clearance before entry into the property, the persons and occupants of the property shall make necessary arrangements with their security personnel so that upon presentation of suitable identification, personnel from the City will be permitted to enter, without delay, for the purposes of performing their specific responsibilities. (C) The City shall not be liable for damage to an assembly that occurs during testing. (D) A water use survey may be conducted at any establishment located in the City which is served by a public water supply or which provides water to the public. Upon determination that the establishment falls under the provisions of this article and requires a backflow prevention assembly, a notice to abate the condition or to install the proper backflow prevention assembly shall be issued. (E) It is the responsibility of the person who owns or controls property to have all assemblies tested in accordance with this article. Assemblies may be required to be tested more frequently if the City deems necessary. (F) All results from assembly testing by a licensed backflow prevention assembly tester shall be placed on a form designated by the City.

( Ordinance 6393 , sec. 1, adopted 4/20/10 )

Ask a question about Garland law

Corpus searches the Garland sections it holds and shows the ones that match, with their citations. Free, no sign-in.