§ 51.79: Reduced pressure principle backflow prevention assemblies.

RPs shall be utilized at any premises where a substance is handled that could be hazardous to the public health if introduced into the potable water system. In addition to the provisions of section 51.76, an RP shall be installed in accordance with the following requirements in order to ensure the proper operation of and accessibility to the assembly: (1) RPs shall be sized to provide an adequate supply of water and pressure for the premises being served. (2) On premises where non-interruption of water supply is critical, two assemblies of the same type installed in parallel shall be provided. The assemblies shall be sized in such a manner that either assembly will provide the minimum water requirements while the two together will provide the maximum flow required. (3) Bypass lines are prohibited. Pipe fittings that could be used for connecting a bypass line shall not be installed. (4) The assembly shall be readily accessible for testing and maintenance and shall be located in an area where water damage to buildings or furnishings will not occur from relief valve discharge. An approved air gap funnel assembly may be used to direct minor discharges away from the assembly provided the air gap funnel assembly will not control flow in a continuous relief situation. Daylight drain ports shall be provided to accommodate full pressure discharge from the assembly. (5) All RP assemblies larger than two (2) inches shall have a minimum of twelve (12) inches clearance on the back side, twenty-four (24) inches clearance on the test cock side, and the relief valve opening shall be at least twelve (12) inches plus nominal size of assembly above the floor or highest possible water level. Headroom of six (6) feet is required in vaults without a fully removable top. A minimum access opening of twenty-four (24) inches square is required on all vault lids. All RP assemblies two (2) inches and smaller shall have at least a six-inch clearance on all sides. RP assemblies may be installed in a vault only if relief valve discharge can be drained to a free and unrestricted space through a boresight type drain. The drain shall be of adequate capacity to carry the full rated flow of the assembly and shall be screened on both ends. (6) An approved air gap shall be located at the relief valve orifice of RP assemblies. The air gap shall be at least twice the inside diameter of the incoming supply line as measured vertically above the top rim of the drain and in no case less than one (1) inch. (7) No deviations from this section shall be permitted without prior written approval of the Managing Director.

( Ordinance 6393 , sec. 1, adopted 4/20/10 )