§ 51.78 — General installation requirements

Code of Ordinances of the City of Garland, Texas (Garland Code of Ordinances, Home Rule Charter and Garland Development Code current through Ordinance 7697 adopted August 17, 2026 (eCode360 publication GA6318, scraped 2026-11-17)) · Garland Code of Ordinances § 51.78

Corpus is an independent public-information project, not the official City of Garland website. Stable reference: corpuslaw.us/code/0a40e1c3-707a-4a92-a512-20648c0a86bc

§ 51.78: General installation requirements.

A backflow prevention assembly shall be installed in accordance with the following requirements in order to ensure the proper operation of and accessibility to the assembly: (1) A backflow prevention assembly shall be installed in accordance with current TCEQ rules and this article. The assembly installer shall obtain the required plumbing permits prior to installation and shall have the assembly inspected by the City. (2) No part of a reduced pressure principle backflow prevention assembly shall be submerged in water or installed in a location subject to flooding. If a double check valve assembly is installed in a vault, brass plugs shall be maintained in the test ports at all times and adequate drainage shall be provided. (3) At facilities which require a backflow prevention assembly to be installed at the point of delivery of the water supply, installation of the assembly must be before any branch in the line and on private property located just inside the boundary between the City’s right-of-way and the landowner’s property. The Managing Director may authorize other areas for installation of the assembly. Assemblies that must be installed in or are located in City rights-of-way are the responsibility of the business or entity that the water line is serving. (4) The assembly shall be protected from freezing and other severe weather conditions. (5) All backflow prevention assemblies shall be of a type and model approved by the Managing Director. (6) All vertical installations of backflow prevention assemblies shall be approved in writing by the Managing Director prior to installation. (7) An assembly installed five (5) feet or higher above floor level shall be equipped with a rigid and permanently installed scaffolding acceptable to the Managing Director which shall contain a platform for use by testing and maintenance personnel. The installation shall meet all applicable requirements of the U.S. Occupational Safety and Health Administration and State occupational safety and health laws. (8) Upon completion of the installation, the premises owner shall notify the Managing Director and schedule the inspection and testing of all assemblies. The premises owner shall register all backflow assemblies with the Managing Director by providing the date of installation, the manufacturer, model and serial number of the backflow prevention assembly, and the initial test report for the assembly. (9) The premises owner assumes all responsibility for any damages resulting from installation, operation, and maintenance of a backflow assembly. The owner shall also see that any vault in which a backflow prevention assembly is contained is kept free of silt and debris that may interfere with the proper operation, inspection or testing of the assembly. (10) Lines shall be thoroughly flushed prior to installation. A strainer with blowout tapping may be required ahead of the assembly. (11) Bypass lines are prohibited. Pipefittings which could be used for connecting a bypass line must not be installed. (12) Premises with two assemblies installed in parallel shall be sized in such a manner that either assembly will provide the maximum flow required. (13) All facilities that require continuous, uninterrupted water service and are required to have a backflow assembly must make provisions for the parallel installation of assemblies of the same type and size so that testing, repair and maintenance can be performed.

( Ordinance 6393 , sec. 1, adopted 4/20/10 )

Ask a question about Garland law

Corpus searches the Garland sections it holds and shows the ones that match, with their citations. Free, no sign-in.