§ 51.74 — Licensed backflow prevention assembly tester responsibilities
Code of Ordinances of the City of Garland, Texas (Garland Code of Ordinances, Home Rule Charter and Garland Development Code current through Ordinance 7697 adopted August 17, 2026 (eCode360 publication GA6318, scraped 2026-11-17)) · Garland Code of Ordinances § 51.74
Corpus is an independent public-information project, not the official City of Garland website. Stable reference: corpuslaw.us/code/d255fefe-8632-4f29-873e-7ad7a6526581
§ 51.74: Licensed backflow prevention assembly tester responsibilities.
(A) Only approved TCEQ licensed backflow prevention assembly testers that are registered with the City in accordance with this article can test backflow prevention assemblies in the City of Garland. (B) An annual licensed backflow assembly tester registration shall remain in effect so long as: (1) The tester maintains eligibility for registration and certification as provided in this article including continued certification by the TCEQ and timely payment of the annual registration fee; (2) The Managing Director has not revoked the registration. (C) Upon recertifying with TCEQ, a tester shall renew the tester’s registration with the Managing Director. (D) An applicant for registration shall: (1) Demonstrate to the Managing Director that the applicant has available the necessary tools and equipment to properly test backflow prevention assemblies; (2) Provide evidence to the Managing Director that the applicant has successfully completed a TCEQ accredited 8-hour hands-on “permit confined-space entry training,” as specified by the occupational safety and health administration (29 CFR 1910.146) within the past 5 years. Non-TCEQ accredited “confined space entry training” will need to be verified and approved by the managing director. Additionally, a TCEQ accredited 8 hours “online confined-space entry training,” successfully completed within the previous twelve (12) months, will also need to be verified and approved by the managing director; (3) Identify all test gauges the applicant will use in testing backflow prevention assemblies. Gauges used in the testing of backflow prevention assemblies shall be tested for accuracy annually in accordance with the University of Southern California’s Manual of Cross-Connection Control or the American Water Works Association Recommended Practice for Backflow Prevention and Cross-connection Control (Manual M14). Testers shall include test gauge serial numbers on “Test and Maintenance” report forms and demonstrate that gauges tested for accuracy; and (4) Testers must register annually with the City, provide proof of TCEQ licensing, and pay an annual, non-refundable tester registration fee. (E) A registered backflow prevention assembly tester shall: (1) File the serial number of each of the tester’s test kits with the Managing Director; (2) Annually have each recorded test kit tested for accuracy and calibrated to maintain a plus or minus 2% accuracy factor; (3) Perform competent and accurate certifications of each backflow prevention assembly tested and submit complete reports thereof to the Managing Director; (4) List registered serial numbers of test gauges on tests and maintenance reports prior to submitting the reports to the Managing Director. (F) A registered backflow prevention assembly tester shall not change the design or operating characteristics of a backflow prevention assembly. (G) After notice and hearing, the Managing Director may revoke a registration if the Managing Director determines that the tester: (1) Has made false, incomplete, or inaccurate assembly testing reports; (2) Has used inaccurate gauges; (3) Has used improper testing procedures; (4) Is not in compliance with safety regulations; (5) Has failed to register the serial numbers of the tester’s test kits or has failed to calibrate gauges annually; or (6) Has violated any other provision of this article. (7) Upon the discretion of the Managing Director upon notice that inappropriate testing activities have taken place.
( Ordinance 6393 , sec. 1, adopted 4/20/10 ; Ordinance 6857 , sec. 7, adopted 9/6/16 ; Ordinance 7396 adopted 1/17/2023 )
Ask a question about Garland law
Corpus searches the Garland sections it holds and shows the ones that match, with their citations. Free, no sign-in.