§ 51.61: Backflow prevention assembly requirements.

(A) With the approval of the Managing Director, a licensed cross-connection tester employed by or under contract or registered with the City shall determine the type and location of any backfiow assembly to be installed within the City’s water service area. The assembly shall be required in each of the following circumstances, but the inspector is in no way limited to the following circumstances: (1) When the nature and extent of any activity at a premises, or the materials or equipment used in connection with any activity at a premises, or materials stored at a premises, could present a health hazard upon entry into the public water system. (2) When a premises has one or more cross-connections. (3) When internal cross-connections are present that are not correctable. (4) When intricate plumbing arrangements are present that make it impractical to ascertain whether cross-connections exist. (5) When a premises has a repeated history of cross-connections being established or re-established. (6) When entry to a premises is restricted so that inspections for cross-connections cannot be made with sufficient thoroughness or frequency to assure that cross-connections do not exist. (7) When materials are being used such that, if backflow should occur, a health hazard could result. (8) When installation of an approved backflow prevention assembly is determined by an inspector to be necessary to accomplish the purpose of these regulations. (9) When an appropriate Cross-Connection Survey Form (CCSI) has not been filed with the Managing Director. (10) On all multistory buildings or any building with a booster pump or elevated storage tank. (11) For any used water return system that has received approval from the Managing Director. (B) In all new nonresidential construction, the Managing Director has the authority to require an approved backflow assembly at the service connection. The type of the assembly will correspond to the degree of hazard as determined by the Managing Director. At any residence or establishment where an actual or potential contamination hazard exists and an adequate internal cross-connection control program is in effect, backflow protection at the water service entrance or meter is not required. (C) When a building is constructed on commercial premises, and the end use of such building is not determined or could change, a reduced pressure principle backflow prevention assembly shall be installed at the service connection to provide protection of the public water supply in the event of the most hazardous use of the building. The use of a backflow prevention assembly at the service connection shall be considered as additional backflow protection and shall not negate the use of backflow protection on internal hazards as outlined and enforced by local plumbing codes. (D) If a point-of-use assembly has not been tested or repaired as required by this article, the installation of a reduced pressure principle assembly will be required at the service connection. (E) If an inspector determines that additions or rearrangements have been made to the plumbing system of a premises without the proper permits as required by the Plumbing Code, premises containment shall be required. (F) Retrofitting shall be required on all point-of-use health hazard connections and wherever else the Managing Director determines that retrofitting is necessary due to circumstances that indicate that cross-connection is likely to occur unless a back-flow prevention assembly is installed. (G) An approved double detector check valve assembly shall be the minimum protection on all new fire sprinkler systems. An RP assembly shall be installed if any solution other than potable water can be introduced into the sprinkler system. Retrofitting shall be required on all high hazard systems, where improper maintenance has occurred, and wherever an inspector determines that such measures are necessary under the conditions found by the inspector.

( Ordinance 6393 , sec. 1, adopted 4/20/10 ; Ordinance 7396 adopted 1/17/2023 )

Ask a question about Garland law

Corpus searches the Garland sections it holds and shows the ones that match, with their citations. Free, no sign-in.