§ 16.16.030 — Water and sewer
Municipal Code of the City of Casper, Wyoming (Codified through Ordinance No. 06-26, adopted July 7, 2026. (Supp. No. 97)) · Casper Municipal Code § 16.16.030
Corpus is an independent public-information project, not the official City of Casper website. Stable reference: corpuslaw.us/code/f81af89d-df7d-4001-8503-bbf167911fa8
16.16.030 - Water and sewer.
A. Authority. 1. The Wyoming Department of Environmental Quality has delegated to the city, via Wyoming Statutes Section 35-11-304, the authority to administer and enforce within its service boundaries Wyoming Statutes Sections 35-11-301(a)(iii) and (v). Specifically, Wyoming Statutes Section 35-11-301 stipulates that no person, except when authorized by permit, shall construct, install or modify any public water supply, sewage system, treatment works, disposal system or other facility capable of causing or contributing to pollution; 2. Consult Title 13, Public Services, of the city of Casper Municipal Code for requirements pertaining to permitting, construction and related requirements for water distribution and sanitary sewer systems. B. Jurisdiction. These standards shall apply to the design and construction of all public or private water distribution and sanitary sewer mains and appurtenances (except for private pump stations), including additions to or replacements of the existing sanitary sewer system. Public water distribution and sanitary sewer mains, and appurtenances are defined as any part of the water distribution or sanitary sewer system owned or controlled by the city of Casper and which are within public streets, roadways, alleys, and easements. Private water distribution and sanitary sewer mains, and appurtenances are defined as being connected to the city of Casper system but which are not owned by the city and are generally outside of public streets, alleys, or easements. C. Casper Public Utilities (CPU). All notes referring to CPU shall be taken to mean the city of Casper public utilities division of the public services department. D. Related Regulations. 1. All water distribution and sewerage collection facilities shall be designed and constructed in compliance with applicable Wyoming Department of Environmental Quality regulations. Nothing contained in this chapter shall be interpreted to reduce those requirements; 2. Consult the city of Casper standard specifications for public works construction and infrastructure improvements (hereinafter referred to as "standard construction specifications"); 3. Consult existing city of Casper rules and regulations and policies regarding water and sewer service. E. Water and sewer agreements. For all plats, replats, and extensions of water and sewer service, a subdivision agreement or water and sewer service contract must be consummated. All outside city agreements must be approved by the Casper city council. F. Preliminary Report. 1. When any new development requires subdivision approval by the city of Casper, a preliminary report shall be submitted at the same time as the preliminary plat or replat is submitted. All preliminary reports must be received and approved by the city of Casper's utilities manager prior to preparation of final construction drawings. The preliminary report must include the following: a. A description of the development service area, including a scaled vicinity map. A review of existing adjacent facilities, including fire hydrants, water mains, and sewer mains within three hundred feet of the proposed development, must be included; b. Applicable engineering design criteria, e.g.: i. Sanitary sewers: average flows, maximum day flows, peak flows, industrial-commercial flows, persons per acre or per unit, etc., and preliminary sizing and design, ii. Water distribution: average demand, maximum day demand, peak demand, fire flow requirements, industrial-commercial flows, persons per acre or per unit, etc., and preliminary sizing and design; c. Capacities and facilities required to provide service for the proposed development. All facilities must be sized and located in accordance with the master plan of wastewater facilities and the master plan of water facilities; provided, however, the city reserves, and has the right to specify, sizes and locations, including those not otherwise delineated on the master plans; d. Proposed method of achieving the desired service, including feasible alternatives; e. General layout of the proposed system, including fire hydrant locations, with indications of any proposed staged development; f. Character of soil through which mains will be laid (soil resistivity measurements may be required). 2. Construction Plans. After approval of the preliminary report, the consultant can prepare construction plans for the sewage collection system and/or the water distribution system in accordance with the approved preliminary report, standard construction specifications and this chapter. G. Booster Stations and Water Storage Tanks. The city shall administer the design and construction of all required publicly owned water booster stations and water storage tanks. Any subdivision requiring the construction of a new booster station or storage tank shall be required to participate in the funding of such construction, either fully or partially, as determined by the city. Booster stations and storage tanks shall be sized and located in accordance with the city of Casper's current master plan of water facilities; provided, however, the city reserves, and has the right to specify sizes and locations, including those not delineated on the master plans. H. Sewage Pumping Stations and Force Mains. The city shall work with the consultant to develop design criteria for all publicly owned sewage pumping stations and force mains. Any subdivision requiring the construction of a new sewage pumping station and force main may be required to fully participate in the cost of design and construction. I. Permits Required. The city engineering office and CPU shall review and approve the plans and specifications for all public or private sewerage collection facilities as follows: 1. Publicly Owned or Controlled Facilities. The Wyoming Department of Environmental Quality has delegated to the city of Casper public utilities the authority to administer and enforce, within its delegated boundaries, W.S. Sections 35-11-301(a), (iii) and (v) (Permits to Construct, Install, or Modify), for all publicly owned or controlled water distribution and sewerage collection facilities. All submitted plans and specifications shall be reviewed, approved, and permits issued in accordance with the city of Casper public utilities' rules and regulations for permits to construct, install, or modify water distribution or sanitary sewerage collection facilities. 2. Privately Owned or Controlled Facilities. Following approval by the city of Casper, plans and specifications shall be submitted to the State Department of Environmental Quality Water Quality Division for their approval. Permits to construct for private systems must be issued by the Wyoming Department of Environmental Quality. J. Record Drawings. The "record drawings" must include the following information for water and sanitary sewer: 1. Contractor's name and address; 2. Construction dates; 3. Distance between water or sewer mains and other utilities; 4. Street names and widths; 5. Mains and sizes; 6. Material of mains; 7. Fire hydrant locations and manufacturer, and model; 8. Water valve locations, manufacturer, and model; 9. Location and types of all anodes; 10. Location of corrosion test stations; 11. Location of tracer/locator boxes; 12. Distances from property lines; 13. Block and lot numbers; 14. House Numbers. These may be obtained from the city building inspection division; 15. Measurements from sewer main to stub-out end. Ends of stub-outs must be tied into permanent reference points and elevations shown; 16. Measurements from water main to curb box. Also, all curb stops must be tied into permanent reference points; 17. Sizes of taps; 18. Distance between fittings; 19. All dead-ends accurately tied into permanent reference points; 20. All tapping sleeves shall be shown; 21. All couplings shall be indicated; 22. Location of all bends (including vertical bends); 23. Size of sewer taps; 24. All manhole invert and top of ring elevations; 25. Distance between manholes or cleanouts; 26. Orientation of north; 27. Scales must be the same scale as those for construction drawings. K. Oversizing. 1. All oversized (ten inches and above) water and sewer mains shall be installed in accordance to the city of Casper's current master plan of wastewater facilities and master plan of water facilities or as directed by the city. All water and sewer lines are to be installed by the developer at his expense. 2. The city of Casper will pay for oversizing costs of water and sewer lines (based on twice the material's cost), generally for sizes over eight-inch diameter (or larger size if required by the project) in accordance to Chapter 16.19 of the Casper City Code. The cost of the eight-inch portion (or larger size if required by the project) of any extension from the existing water or sewer system to the boundary of the property requesting service shall be at the expense of the developer. The costs of an eight-inch system (or larger size if required by the development for its internal service) within the project shall be borne by the developer. An oversizing reimbursement may only be allowed for the size, as required by the city over the size reasonably required and any surrounding land also owned by the developer, and/or other partnerships or corporations in which the developer has an interest. 3. In the event a development requires such facilities as to be financially unfeasible, in the opinion of city, the developer may be required (in the agreement or service contract) to provide such additional contribution as the city may specify. 4. To obtain the oversizing contribution from the city, a list is needed of all oversizing quantities on each applicable "record drawing" arranged by street. The quantities must be certified correct by the engineer in accordance to Chapter 16.19 of the Casper Municipal Code. 5. The oversizing contribution will be determined by city based on material costs generally prevailing at the time of the agreement. Contributions will be provided by city upon acceptance of the facilities. L. Preliminary Acceptance. 1. Sanitary Sewer. Prior to preliminary acceptance of a sanitary sewer system, regardless of ownership, the following inspection tests shall be made and certified for each section of sewer (not applicable for townhouse manifold systems): a. Refer to Section 601.11 of the standard construction specifications. 2. Water Distribution. Prior to preliminary acceptance of a water distribution system, regardless of ownership, the following inspection tests shall be made and certified for each section of water line (not applicable for townhouse manifold systems): a. Refer to the standard construction specifications Section 501.14A; b. If allowed by the water and sewer contract or the subdivision agreement, the city can recommend the issuance of building permits following preliminary acceptance; c. The city of Casper plumbing inspector shall inspect and accept townhouse manifold systems. M. Final Acceptance. 1. Refer to the standard construction specifications Sections 501.14b and 601.11c; 2. If a developer or owner does not proceed in an expeditious manner to obtain final acceptance, the city engineer may recommend against the issuance of remaining building permits; 3. No oversizing contribution will be made until after final acceptance; 4. Upon final acceptance, public systems shall become the property of the city of Casper. The developer shall demonstrate to the satisfaction of the city engineer that no liens have been or will be filed upon the facilities which have been installed and are to become the property of the city; 5. The warranty period shall not start until final acceptance is obtained.
(Ord. 2-06 (part), 2006) (Ord. No. 11-24, § 6, 6-18-2024)
Ask a question about Casper law
Corpus searches the Casper sections it holds and shows the ones that match, with their citations. Free, no sign-in.