For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 16.16.080 — Public grounds improvements

Municipal Code of the City of Casper, Wyoming (Codified through Ordinance No. 06-26, adopted July 7, 2026. (Supp. No. 97)) · Casper Municipal Code § 16.16.080

Corpus is an independent public-information project, not the official City of Casper website. Stable reference: corpuslaw.us/code/b62c12ac-16c0-430f-b666-a83498c02d03

16.16.080 - Public grounds improvements.

A. General. These standards are intended to supplement requirements of the Casper Municipal Code and provide minimum requirements for design of landscaping on public property, parks and athletic fields. Refer to the other city of Casper design standards for the following: 1. Streetscape standards for the downtown area; 2. Park standards; 3. Bikeway and trail standards; 4. Parking lot standards. All designs shall be submitted to the city of Casper for review and approval prior to bidding or construction. B. Trees and Shrubs in Public Areas. 1. Spacing Restrictions. a. Trees or shrubs are not permitted where there is less than five feet between the back of curb and the sidewalk. b. Trees or shrubs shall be placed no closer than ten feet to any fire hydrant or utility pole. c. At street intersections, trees or shrubs shall not be placed within the area of a triangle formed as follows: two legs are formed by the centerlines of the intersecting streets. A line drawn from points on each leg, ninety feet from the intersection of the centerlines forms the base of the triangle. d. Large trees shall be spaced a minimum of forty feet apart. e. Small trees shall be spaced a minimum of twenty feet apart. f. Trees shall not be placed less than fifteen feet from driveways and alleys. g. Trees shall not be placed under or closer than ten feet horizontally of any overhead utility wire or closer than five feet to any underground utility. h. Trees of the genus populus shall not be placed closer than fifty feet to any underground water or sewer line. i. Large trees shall not be placed closer than two feet of any curb or sidewalk. h. Small trees shall not be placed closer than four feet of any curb or sidewalk. 2. Prohibited Species. a. Any cotton bearing cottonwood tree or genus populus; b. Any female boxelder tree (acer negundo); c. Any willow (genus salix). C. Irrigation Systems. 1. All exposed equipment such as irrigation controller boxes, reduced pressure backflow prevention device enclosures, meter pedestals, pump enclosures, electrical panels, etc., shall be power-coated green to match the "strong box" color RAL 6005 or Cardinal Industrial Finishes #T007-GN16 traffic green. If the items cannot be power-coated prior to installation, they may be field-painted to match the above; 2. Irrigation shall be designed to irrigate the entire area no more than eight hours a day at the rate of one-half inch per eight-hour period, to apply two inches of precipitation over four days; 3. Type of controller to be designated by city of Casper parks division prior to bid, Motorola MIR 5000 or a commercial controller; 4. Tree watering to provide five gpm per tree, and number of days per week according to soil conditions. Install a three-fourth inch quick coupling at the end of the line to winterize the system. Winter watering shall be done by contractor; 5. Any new city buildings in a park shall have a separate irrigation system and water tap; 6. Guarantee. The entire irrigation and water system shall be guaranteed for a period of one year from date of acceptance by the owner. The contractor shall mow the park once a week and control all weeds for the first year; 7. Guarantee Period Services. The contractor shall winterize the system and perform spring start-up of the system during the guarantee period; 8. Contractor shall provide record drawings with location of all buried piping, wiring and other improvements; 9. Any irrigation placed under asphalt and/or cement shall be blown out (winterized) first, by the contractor, to prevent possible freeze breaks while still under warranty; 10. Any irrigation placed under asphalt and/or cement shall be installed in PVC pipe sleeves a minimum of three inches in diameter or one-pipe size larger than the irrigation pipe, whichever is larger; 11. All reduced pressure backflow preventers, water meters, and blowouts shall be checked by authorized city personnel before releasing irrigation to the proper city department's responsibility; 12. Sprinklers to be adjusted to arc or full circle to meet coverage needs. Straighten and adjust heads to proper height; 13. Swing joints must be installed on same side as PVC pipe. It may not cross the PVC laterally; 14. Thrust blocks may not exceed twelve inches by twelve inches square, with no wires encased in the cement. In addition, the wires are to have twenty inches of loop at all ninety and forty-five-degree pipe bends. It also must be looped at the tees and the valves; 15. Mainline PVC shall not be less than eighteen inches in depth and twelve inches in depth for the lateral lines; 16. Valve boxes and sprinkler heads must be level and one inch below finished grade; 17. Valve clusters must be at least three feet apart to leave room for any maintenance needs; 18. Glue. PVC pipe must be cleaned with primer and glued with plenty of glue with at least one-fourth to one-half turn on the adjoining pipe regardless of pipe diameter; 19. A minimum of four inches of fill shall separate each pipe if using a common trench; 20. All pipes must be backfilled with a minimum of three inches of sand before using existing material; 21. All valves must be checked to see if they work through the controller, even those for future use. All wires must be marked in the controller according to the actual valve it corresponds with; 22. Water schedule must be approved by city and have appropriate days off for maintenance needs, such as mowing. D. Parks. 1. One shelter for three acres of parkland according to park design; 2. Walkways at the curb and pathways through the park, paved bar-b-que pads for venders, to be ten feet wide to accommodate snow removal equipment. Six inches of base, four inches of asphalt, in two equal lifts; 3. Ten parking spaces, including one ADA space for every three acres; 4. Playground equipment to conform to the Consumers Product Safety Commission and American Society for Testing and Materials Standards; 5. Park signs will be recycled plastic or monument style according to park requirements; 6. Trees shall be selected by parks division manager prior to the bid; 7. Comply with arboricultural specifications and standards of practice for contractors that is part of the city of Casper standard specifications for public works construction and infrastructure improvements; 8. Barricades around the park to be of boulders, or six-foot by six-foot treated posts, six feet long, three feet out of the ground, and five feet apart, top to be cut at a forty-five-degree angle. Any barricades bordering roadways or marking entrances shall have reflectors; 9. Slopes to be no greater than twenty degrees (3:1), for mowing safety; 10. Park lighting to be mounted in a concrete base, twenty-four inches in diameter, twenty-four inches long, top of concrete to be six inches below the hand-hole. Poles and fixtures shall be: a. Ameron—centrecon series, embedded octagonal pole, spun-cast, prestressed concrete poles, b. Color shall be selected by owner, c. Luminaire arm—six-foot davit arm, d. Utility light (cobra head)—two hundred fifty watt pressure sodium, dropped glass, e. Anti-graffiti and sealer; 11. For direct bury poles, provide a twenty-four inch diameter by twenty-four inch deep concrete base. Color shall be approved of by owner; 12. Drainage ditches are prohibited. Provide for the proper drainage pipe buried and landscaped; 13. Electrical power for parks—Milbank, Midwest or equal meter main pedestal: a. 240/120 volt, b. Single phase, c. One hundred twenty-five amp minimum, d. Six circuit minimum; 14. At the time of construction in a new subdivision, tap size for donated parkland shall be determined by park acreage and the appropriate size water line installed to the park property. 3 acres and less | 2-inch water tap 3 acres to 8 acres | 4-inch water tap 8 acres to 16 acres | 2 to 4-inch water taps 15. Donated parkland shall be usable and accessible. E. Athletic Fields. 1. Baseball/softball field dugouts are to have the flooring one inch higher than drainage grade of the playing surface, i.e., no sunken dugouts; 2. One percent minimum grade on full playing surface from center; 3. Infield surface mix shall be one hundred percent crushed limestone meeting the following specification: Size | % Passing ⅜′ | 100% #8 | 90—100% #60 | 35—45% #200 | 20—30% Soundness (5 cycle Mg SO4) | max 15% Abrasion loss (LAR) | max 30% Absorption | max 3.5% 4. Any overseeding, sod, and/or sod patching shall be level with grade and the drainage inspected, i.e., any high or low grades must be corrected; 5. Topsoil placed on athletic fields shall be a minimum of four inches deep for turf areas; 6. One year minimum warranty on all contract work shall include, but not limited to: a. Proper irrigation maintenance such as startup and winterizing, b. Landscape vegetation, c. Weed control; 7. The contractor shall do own locates for the warranted irrigation and wiring for further contract work to be done; 8. All lighting shall meet ASTM standards for leagues using the facility.

(Ord. 2-06 (part), 2006)

Ask a question about Casper law

Corpus searches the Casper sections it holds and shows the ones that match, with their citations. Free, no sign-in.