16.16.040 - Sanitary sewerage collection facilities.

A. Related Regulations. All designs shall be in accordance with these standards: the Wyoming Department of Environmental Quality Water Quality Rules and Regulations, Chapter XI, the Uniform Plumbing Code, as adopted by the city of Casper; and other city ordinances, rules and regulations, and policies. B. Design Period. All sanitary sewers and appurtenances shall be designed to carry the design flows from all contiguous or adjacent areas that may, within a reasonable period in the future, be tributary thereto. Contiguous or adjacent areas to be included in the design and the tributary population to be provided for shall be subject to approval by the city. All mains ten inches and larger shall be sized and located in accordance with the current master plan of wastewater facilities; provided, however, the city reserves and has the right to specify sizes and locations, including those not delineated on the master plan. C. Design Flows. 1. Sanitary sewers must be designed to carry the peak discharge and to transport suspended material so that deposition in the sewer is precluded. 2. The consultant shall substantiate and have approved by the city population densities per acre or per unit. 3. New sewer systems shall be designed on the basis of an average daily per capita flow of not less than one hundred gallons per day. This figure is assumed to provide for a normal infiltration, but an additional allowance should be made where conditions are unfavorable. To provide for peak loads, sanitary sewers shall be designed for peak flow to average flow at 0.75 pipe diameter depth, ratios of 4:1 for lateral sewers (eight inches); 3.5:1 for collector sewers (ten inches through fifteen inches); and 2.5:1 for interceptor sewers (eighteen inches and larger). 4. When deviations from the foregoing procedure are requested, a description of the design procedure used shall be submitted with the plans and specifications for approval. 5. The following sewage flow parameters shall be used as a general guideline for minimum estimated average flows generated from nonresidential land use: Commercial areas | 1,000 gal./acre/day Infiltration-inflow allowance | 500 gal./acre/day D. Depth of Cover. In general, sanitary sewers shall be designed with sufficient depth to permit floor drains from basements to be connected, unless in subdivisions or areas in which no basements are to be constructed, in which instance, the developer shall sign a statement to this fact on all plans presented for approval. In no case shall sanitary sewers be designed for a depth of cover less than thirty-six inches over the top of the pipe or sewer. Where shallower depths are unavoidable, consideration may be given to the construction of epoxy-lined or polyurethane-lined ductile iron, or similarly protected sewer, with or without insulation, as circumstance may direct. Proper allowance for loads on the sewer shall be made because of width and depth of trench. Rigid pipe shall have a minimum factor of safety of 1.5. Flexible pipe shall have a minimum factor of safety of 1.25. Where necessary, special construction will be required. E. Velocity of Flow. 1. All sewers shall be designed and constructed with hydraulic slopes sufficient to give mean velocities, when flowing full, of not less than two feet per second, based on Manning's formula, using a value for "n" of 0.013. The following shall be the minimum slopes to be provided: Sewer Size (inches) | Minimum Slope (ft./100 ft.) 4 | 2.0 6 | 0.80 8 | 0.40 10 | 0.28 12 | 0.22 15 | 0.15 18 | 0.12 21 | 0.10 24 | 0.08 27 | 0.067 30 | 0.058 33 | 0.051 36 | 0.046 2. The engineer must furnish computations for velocities and depth of flow for grades in excess of eight percent and for extremely low flow situations. F. Minimum Size. No public sanitary sewer shall be less than eight inches in diameter. The minimum size of house connections shall be four inches in diameter. G. Alignment. 1. In general, sewers shall be designed for uniform slope and alignment between manholes, and shall be located parallel to and with a minimum of ten feet separation from water lines. Curvilinear sewers will be permitted only for sewers fifteen inches in diameter and larger. 2. The energy gradient line shall be maintained whenever a smaller sewer joins a larger sewer. This can be approximated by placing the 0.8 depth of both sewers at the same elevation (not considering head loss through the manhole). H. Manholes. 1. Manholes shall be installed at the end of each line, at all changes in grade, size, or alignment, at all sewer main intersections, and at distances not greater than four hundred feet apart for sewers fifteen inches in diameter or less, and not greater than four hundred fifty feet apart for sewers eighteen inches in diameter or larger. 2. Four-foot-diameter manholes may be used for pipes up to eighteen inches in diameter. Five-foot manhole shall be used for pipes twenty-one inches in diameter and larger. 3. Lamp holes will not be acceptable as a substitute for manholes. 4. Drop manholes shall be provided for a lateral sewer entering a manhole at an elevation of eighteen inches or more above the manhole invert. Drop manholes shall be avoided whenever it is feasible to do so. The upper pipe at drop inlets shall extend into the manhole twelve inches with the top half cut out. 5. Floor troughs shall be furnished for all sewers entering manholes. A larger diameter manhole may be needed in order to properly construct floor troughs where the incoming sewer inverts are substantially higher than the outgoing sewer invert. At all manholes with a change of direction, a drop from entrance to outlet of at least 0.1 foot shall be provided to account for head loss through the manhole. More drop may be required for sewer mains twelve inches and larger. Inverts shall be U-shaped to the pipe crown before sloping at a one to twelve slope to the manhole walls. 6. All manholes shall conform to the detailed dimensions, construction details, materials, and testing requirements, as detailed in the city of Casper standard specifications for public works construction and infrastructure improvements. 7. When directed by the city, manholes shall be internally coated for corrosion protection in accordance with the standard construction specifications. I. Service Connections. 1. Service connections to any sanitary sewer shall be made only to a wye installed at the time of the sewer main installation or by machine tap and approved saddle appropriate to the main line sewer material. All connections to existing public sewers shall be made by the city. All wyes and service connections must be made at the ten o'clock or two o'clock position on the sewer main. 2. All connections and service lines must be watertight. 3. All service connections shall be sized in accordance with the Uniform Plumbing Code. 4. A groundwater barrier, installed in accordance with the details included in the city of Casper standard specifications for public works construction and infrastructure improvements, shall be provided for all service lines at the property line. 5. Only one residence, structure, or building shall be served by each lateral connected to the public or private main, unless as approved by the city. 6. Commercial and Industrial Wastes. Attention is directed to city of Casper Municipal Code Chapters 13.20 through 13.44, relative to the use of the public sewers and the requirements for discharge of certain materials (pretreatment). An inspection manhole or other suitable structure shall be required on the service line for any use other than normal domestic use. In addition to the above, acceptable grease interceptors will be required of all restaurants, food preparation centers, or for any other discharge containing oil and grease. Acceptable sand and oil interceptors must be provided for all car washes and similar facilities which may discharge sand or dirt to the sewer. J. Roof or Foundation Drains. Under no circumstance shall roof drains, foundation drains, storm drains, or subdrains be connected to the sanitary sewer system. K. Townhouse Manifolds. 1. Townhouse developments may elect to use a "manifold" sewage collection system for service to individual properties, if a valid homeowner's association exists among all property owners. This "manifold" system is restricted to townhouse developments and must conform to the following requirements: a. The "manifold" system must be owned and maintained by a viable homeowner's association. The homeowner's association will be responsible for the manifold to the point of connection with the sewer main. b. No more than four privately owned units may be placed on any "manifold." c. The "manifold" shall be located at the back side of the front lot utility easement. d. The common header pipe to the main shall be six inches in size and shall be provided with cleanouts at the ends and at all bends. e. The city of Casper shall review and approve the plans for the manifold construction. Following city of Casper approval, plans and specifications shall be submitted to the State Department of Environmental Quality for their approval (private systems need DEQ approval). f. The "manifold" shall meet all requirements of the Uniform Plumbing Code, as adopted by the city of Casper. The inspection of the "manifold" beyond the sewer main shall be accomplished by the city of Casper plumbing inspector. L. Mobile Home Communities. 1. All mobile home communities utilizing public streets and utilities shall be designed in accordance to these standards. 2. Mobile home rental communities (private) shall be designed in accordance to Part F of the Wyoming Department of Environmental Quality Water Quality Rules and Regulations, Chapter XI. Following city of Casper approval, the plans and specifications shall be submitted to the State Department of Environmental Quality for approval. M. Other Design Criteria. 1. All easements containing only sewer mains must be at least twenty feet in width and graded so that every manhole will be accessible to maintenance equipment. Easements containing both water and sewer mains must be at least thirty feet in width. No other utilities or related items (sprinkler systems, buildings, sidewalks, electric cables, etc.) shall be installed in the easement unless approved by the city of Casper. 2. Materials approved for main construction include (see city of Casper standard specifications for public works construction and infrastructure improvements): a. Polyvinyl chloride (PVC)—Conform to ASTM D-3034, SDR 35 for four inches through fifteen inches. Conform to ASTM F679 TYPE 1, SDR 35 for eighteen inches through twenty-seven inches; b. Ductile iron in conformance to Section 601.02c of city of Casper standard specifications for public works construction and infrastructure improvements. 3. Materials approved for service connections include: a. Polyvinyl chloride—Conform to ASTM D-2665 Schedule 40 or ASTM D-3034 SDR 35; b. ABS plastic—Conform to ASTM D-2661. 4. Materials and methods approved for sewer system construction, and other design and construction details may be found in the city of Casper standard specifications for public works construction and infrastructure improvements. 5. All sewers shall be designed to prevent damage from superimposed loads as well as trench-loading conditions. All sewers are to be bedded, as required by the city of Casper standard specifications for public works construction and infrastructure improvements or as otherwise specified by the engineer and approved by the city of Casper. 6. Water mains shall be laid at least ten feet horizontally from any sanitary sewer, storm sewer, or sewer manhole, whenever possible. The distance shall be measured edge-to-edge. When local conditions prevent a horizontal separation of ten feet, a water main may be laid closer to a storm or sanitary sewer, provided that such construction is strictly in accordance with Section 601.10 of the city of Casper standard specifications for public works construction and infrastructure improvements. 7. Water mains crossing house sewers, storm sewers, or sanitary sewers shall be laid above the sewers to provide a separation of at least eighteen inches between the bottom of the water main and the top of the sewer, whenever possible. When local conditions prevent a vertical separation, as described in this section, construction shall be strictly in accordance with Section 601.10 of the city of Casper standard specifications for public works construction and infrastructure improvements. 8. Where velocities greater than ten feet per second are attained, special provision shall be made to protect against displacement by erosion and shock. 9. There shall be no physical connection between a public or private potable water supply system and a sewer, or appurtenance thereto which would permit the passage of any sewerage or polluted water into the potable supply. 10. Sewers on twenty percent slope or greater shall be anchored securely with concrete anchors, or equal, spaced as follows: a. Not over thirty-six feet center-to-center on grades twenty percent and up to thirty-five percent; b. Not over twenty-four feet center-to-center on grades thirty-five percent and up to fifty percent; c. Not over sixteen feet center-to-center on grades fifty percent and over. 11. New materials, equipment, or technology, not covered by these design standards or the city of Casper standard specifications for public works construction and infrastructure improvements, may be considered on an individual basis if such a variance has the potential to initiate more cost-effective service to the citizens of Casper. Facilities not covered by these standards must be reviewed and approved jointly by the city of Casper and the Department of Environmental Quality, in accordance with Section 5 of the Wyoming Department of Environmental Quality, Water Quality Rules and Regulations, Chapter XI.

(Ord. 2-06 (part), 2006)

Ask a question about Casper law

Corpus searches the Casper sections it holds and shows the ones that match, with their citations. Free, no sign-in.