For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 16.16.070 — Stormwater facilities

Municipal Code of the City of Casper, Wyoming (Codified through Ordinance No. 06-26, adopted July 7, 2026. (Supp. No. 97)) · Casper Municipal Code § 16.16.070

Corpus is an independent public-information project, not the official City of Casper website. Stable reference: corpuslaw.us/code/37fc87ff-59e5-4430-b7d3-8ecb53420ad3

16.16.070 - Stormwater facilities.

A. General. Design of all stormwater facilities within the city shall be in conformance with the city's stormwater management master plan and the Storm Water Management Design Manual. B. Drainage Studies. Drainage studies shall be performed by a professional engineer registered in Wyoming and shall include the following: 1. Preliminary design and layout of both existing and proposed storm sewer system; 2. Data and calculations for developed and undeveloped flow for ten-year and one-hundred-year storms; 3. Description and location of all proposed detention ponds; 4. Analysis of the capacity of downstream system and effect on the drainage system and impacts on all adjacent roads; 5. Analysis of the effect of the drainage system on the drainage basin; 6. All calculations and methodology used to support the data; 7. Design policies that follow Casper's 1983 Storm Water Management Design Manual. C. Special Considerations. 1. Metal piping shall not be used in storm drainage systems unless approved of by the city engineer. Systems shall be designed to use reinforced concrete pipe wherever possible. 2. The use of "slot drains" is discouraged. Slot drains shall not be used unless expressly permitted by the city engineer. All slot drains shall have access through a manhole or catch basin for cleaning. 3. On-site detention of stormwater is required in some areas of Casper. Where detention is required, compliance with the following criteria shall be met: a. Limit the release rate from detention structures to the peak flow from the ten-year, two-hour storm, for the site in undeveloped condition; b. Calculate the storage volume required based on the difference between the release rate and the flows for different storm durations, calculated by the modified rational method for the ten-year storm; c. Provide provisions for overflow, for flows exceeding those generated by the ten-year storm; d. Outlet flows from detention reservoirs shall be piped underground to a storm sewer system. Outlet flows shall not be conveyed to a street curb and gutter system. 4. Trash racks shall be provided for the upstream inlet end of storm sewer pipes only. Do not design them for downstream outlets. 5. The minimum size for storm drain pipe is fifteen inches, including laterals and culverts, unless approved by the city of Casper engineer. 6. All surface water flows in street gutter sections exceeding ten feet per second in velocity shall be carried by an underground storm sewer system, regardless whether flow is contained in the parking lane or concrete curb and gutter.

(Ord. 2-06 (part), 2006)

Ask a question about Casper law

Corpus searches the Casper sections it holds and shows the ones that match, with their citations. Free, no sign-in.