For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 15.35.100 — Amendment to 2025 CFC Section 202 (General definitions)

Fremont Municipal Code (Fremont Municipal Code current through Ordinance 02-2026 passed May 5, 2026 (Code Publishing Company, codepublishing.com, scraped 2026-11-18)) · Fremont Municipal Code § 15.35.100

Corpus is an independent public-information project, not the official City of Fremont website. Stable reference: corpuslaw.us/code/eb8bedc3-77b2-434a-a918-5d25da604c42

15.35.100 Amendment to 2025 CFC Section 202 (General definitions).

Section 202 of the 2025 California Fire Code is amended by adding or modifying the following definitions. The remaining definitions in Section 202 are not modified. ABANDONED shall mean tanks out of service and not being monitored in accordance with this Article and the provisions of the California Health and Safety Code shall be considered abandoned. CONTINUOUS GAS-DETECTION SYSTEM is a gas-detection system where the analytical instrument is maintained in continuous operation and sampling is performed without interruption. Analysis shall be performed on a cyclical basis at intervals not to exceed five minutes. CORROSIVE LIQUID is a liquid which, when in contact with living tissue, will cause destruction or irreversible alteration of such tissue by chemical action. Examples include acidic, alkaline or caustic materials. Such material will be considered prima facie corrosive when the pH is 2 or less or 12.5 or more, except for foodstuffs or medicine. This includes materials classified by DOT and Title 22 as corrosives. CURRENT CODE shall mean the edition of the California Building, Fire or other California Building Standards Codes published by the International Code Council as adopted by the city of Fremont under California Health and Safety Code Section 18941.5. The edition to be applied shall be that edition in effect at the time damage occurs. ENGINEERING EVALUATION means an evaluation of a suspected damaged building or structure, performed under the direction of a fire protection engineer, structural engineer, civil engineer or architect retained by the owner of the building or structure. Engineering evaluations shall, at a minimum, contain recommendations for repair with an appropriate estimate of the construction cost for those repairs. ESSENTIAL SERVICE FACILITY shall mean that building or structure which has been designated by the city council to house facilities that are necessary for emergency operations. HIGHLY TOXIC {CFC text not modified} 1. – 3. {CFC text not modified} 4. A chemical that has a health hazard ranking of 4 in accordance with NFPA Standard 704. JURISDICTION means the city of Fremont. LOCAL FIRE ALARM shall mean a fire alarm system provided for notification and evacuation of occupants. It shall have more than one notification appliance on each and every floor. The system may notify a monitoring company at the discretion of the fire marshal. REMOVAL – tanks abandoned or permanently out of service shall be removed from the ground. Tanks required to be removed by this code shall be removed and disposed of in a manner approved by the chief, or his authorized representative. Whenever a tank is required to be removed by this section, the chief may require removal of all levels of containment, foundations, structures, or similar items which would obstruct soil sampling or cleanup of contaminated soil. REPLACEMENT VALUE is the dollar value, as determined by the building official based upon the square footage and the guidelines used in establishing the valuation of new construction, of replacing the damaged structure with a new structure of the same size, construction material and occupancy on the same site. SECONDARY CONTAINMENT is that level of containment that is external to and separate from primary containment and is capable of safely and securely containing the material, without discharge, for a period of time reasonably necessary to ensure detection and remedy of the primary containment failure. SEGREGATED is storage in the same room or area but physically separated by distance and independent secondary containment from incompatible materials. SEMICONDUCTOR FABRICATION FACILITY OR COMPARABLE MANUFACTURING, RESEARCH AND DEVELOPMENT AREAS is a building or portion of a building classified as a Group H Occupancy in which electrical circuits or similarly manufactured devices are created. SPECULATIVE WAREHOUSING is a building constructed without specific use, occupancy hazard designation, or tenant. Buildings that do not have a designed fire sprinkler system for a specific use (occupancy) or storage commodity classification. STORAGE OR USE FACILITY is a building, portion of a building, or exterior area used for the storage, use, or handling of hazardous materials where the quantity of hazardous materials is equal to or greater than the permit amounts specified in Chapter 1, Section 105. STORAGE OR USE SYSTEM is any one or combination of tanks, sumps, waste treatment facilities, pipes, vaults or other portable or fixed containers, and their secondary containment systems which are used, or designed to be used, for the storage, use, or handling of hazardous materials at a storage or use facility. For purposes of this code, a workstation having limited quantities of hazardous materials shall not be treated as a storage system. TEMPORARY INSTALLATIONS shall mean those that do not exceed one year. TOXIC {CFC text not modified} 1. – 3. {CFC text not modified} 4. A chemical that has a health hazard rating of 3 in accordance with NFPA Standard 704. VALUE OF REPAIR is the dollar value, as determined by the building official, of making the necessary repairs to a damaged structure. WASTE OIL is a Class III-B waste liquid resulting from the use of Class III-B combustible liquids such as waste motor oil, hydraulic oil, lubricating oil, brake fluids and transmission fluids. (Ord. 11-2025 § 2, 9-16-25.)

Ask a question about Fremont law

Corpus searches the Fremont sections it holds and shows the ones that match, with their citations. Free, no sign-in.