15.35.280 Amendment to 2025 CFC Section 5005 (Use, Dispensing and Handling).
Section 5005 of the 2025 California Fire Code is amended as follows: Table 5005.2.1.4 (Required Secondary Containment-Hazardous Liquids Use) is deleted. 5005.1 – 5005.2.1.2 {CFC text not modified} 5005.2.2 – 5005.2.2.2 {CFC text not modified} 5005.2.2.3 Spill control for hazardous materials liquids. Buildings, rooms or areas where hazardous materials liquids are used shall be provided with spill control in accordance with Section 5004.2.1. 5005.2.2.4 Secondary containment for hazardous materials liquids. Buildings, rooms or areas where hazardous materials liquids are used in vessels or systems shall be provided with secondary containment in accordance with Section 5004.2.2 when the capacity of an individual vessel or system or the capacity of multiple vessels or systems exceeds the following: 1. Individual Vessel or System: Greater than 55 gallons (208.2 L) 2. Multiple Vessels or Systems: Greater than 1,000 gallons (3785 L) 5005.3 – 5005.3.3 {CFC text not modified} 5005.3.4 Spill control for hazardous materials liquids in open systems. Outdoor areas where hazardous materials liquids are dispensed or used in open systems shall be provided with spill control in accordance with Section 5004.2.1. 5005.3.5 Secondary containment for hazardous materials liquids in open systems. Buildings, rooms or areas where hazardous materials liquids are dispensed or used in open systems shall be provided with secondary containment in accordance with Section 5004.2.2 when the capacity of an individual vessel or system or the capacity of multiple vessels or systems exceeds the following: 1. Individual Vessel or System: Greater than 1.3 gallons (5 L) 2. Multiple Vessels or Systems: Greater than 5.3 gallons (20 L) 5005.3.6 Spill control for hazardous materials liquids in closed systems. Outdoor areas where hazardous materials liquids are used in closed systems shall be provided with spill control in accordance with Section 5004.2.1. 5005.3.7 Secondary containment for hazardous materials liquids in closed systems. Outdoor areas where hazardous materials liquids are dispensed or used in closed systems shall be provided with secondary containment in accordance with Section 5004.2.2 when the capacity of an individual vessel or system or the capacity of multiple vessels or systems exceeds the following: 1. Individual Vessel or System: Greater than 55 gallons (208.2 L) 2. Multiple Vessels or Systems: Greater than 1,000 gallons (3785 L) 5005.3.8 – 5005.4.4 {CFC text not modified} (Ord. 11-2025 § 2, 9-16-25.)
Ask a question about Fremont law
Corpus searches the Fremont sections it holds and shows the ones that match, with their citations. Free, no sign-in.