§ 15.35.350 — Amendment to 2025 CFC Chapter 80 (Referenced Standards)

Fremont Municipal Code (Fremont Municipal Code current through Ordinance 02-2026 passed May 5, 2026 (Code Publishing Company, codepublishing.com, scraped 2026-11-18)) · Fremont Municipal Code § 15.35.350

Corpus is an independent public-information project, not the official City of Fremont website. Stable reference: corpuslaw.us/code/7c4a5f29-864e-456a-8d6e-07e7fd073de0

15.35.350 Amendment to 2025 CFC Chapter 80 (Referenced Standards).

Chapter 80 of the 2025 California Fire Code and the referenced standards contained therein are amended as follows: (a) NFPA 13-25 is amended to read: 2.2 – 9.2.1.16 {CFC text not modified} 9.2.3.1 Sprinklers shall be installed under exterior canopies, roofs, porte-cocheres, balconies, decks, or similar projections exceeding 4 feet in depth. 9.2.3.2 – Sprinklers shall be installed under exterior projections exceeding 4 feet in depth. 9.3.19.1. Sprinklers shall be installed under exterior canopies, roofs, porte-cocheres, balconies, decks, or similar projections exceeding 4 feet in depth. A9.3.19.2 {CFC text not modified} 9.3.19.3 (2) Solar Photovoltaic (PV) panels supported by non-combustible framing. 16.9.3.1.3.5 – 29.6.1 {CFC text not modified} (b) NFPA 13D-25 is amended to read: 5.1.1.2 A spare sprinkler of each type and their specialized sprinkler wrench shall be installed in a spare head box located near the riser, hot water heater, furnace or in locations approved by the Fire Code official. 6.2. Water Supply Sources. When approved by the Fire Code Official and the requirements are met, the following water supply sources shall be acceptable by this standard. 1. A connection to a reliable waterworks system with or without an automatically operated pump 2. An elevated tank 3. A pressure tank designed to American Society of Mechanical Engineers (ASME) standards for the pressure vessel with a reliable pressure source. 4. A stored water source with an automatically operated pump. 5. A well with a pump of sufficient capacity and pressure to meet the sprinkler system demand. The stored water requirement of 6.1.2 or 6.1.3 shall be permitted to be a combination of the water and the well (including the refill rate) plus the water in the holding tank if such tank can supply the sprinkler system. 6.2.2.1 – 6.2.33 {CFC text not modified} 8.3.4 – Deleted (c) NFPA 1424 is amended to read: 6.3.7.1 System Water Supply valves, isolation control valves and other valves in fire mains shall be supervised in an approved manner in an open position by one of the following approved methods: 1. Where a building has a fire alarm system or a sprinkler monitoring system installed, the valve shall be supervised by: a. A central station, proprietary or remote supervising station. b. Deleted 2. When a building does not have a fire alarm system or a sprinkler monitoring system installed, the valve shall be supervised by (a & b): a. Locking the valves in the open position or b. Sealing valves in an approved weekly recorded inspection where valves are located within fenced enclosures under the control of the owner. (d) NFPA 15-22 through 22-23 {CFC text not modified} (e) NFPA 24-25 is amended to read: 4.2.1 –5.5.5.1 {CFC text not modified} 6.6.1.1 – deleted 6.6.1.2 – 6.6.1.4 {CFC text not modified} 10.4.3.1.1 Delete exceptions 1 & 2 (f) NFPA 25-13 CA through 70-23 {CFC text not modified} (g) Section NFPA 72 is amended to read: 10.3.1 – 23.8.1.2.1 {CFC text not modified} 23.8.5.1.2 – Exception deleted 23.8.5.4.1 –29.10.6.8.1 {CFC text not modified} (h) NFPA 76-24 through NFPA 2010-23 {CFC text not modified}. (Ord. 11-2025 § 2, 9-16-25.)

Ask a question about Fremont law

Corpus searches the Fremont sections it holds and shows the ones that match, with their citations. Free, no sign-in.