§ 1204.1 — MINIMUM REQUIRED AIR GAP

Atlanta City Code (Code of Ordinances, Part II) (Supp. No. 108, Update 1: codified through Ordinance No. 2026-37 (26-O-1511), enacted September 30, 2026) · Atlanta Land Development Code, App. C, ch. I, § 1204.1

Corpus is an independent public-information project, not the official City of Atlanta website. Stable reference: corpuslaw.us/code/d9fe2920-d501-49a2-a994-d433c770cff9

1204.1. - MINIMUM REQUIRED AIR GAP.

(a) How Measured. The minimum required air gap shall be measured vertically from the lowest end of a potable water outlet to the flood rim or line of the fixture or receptacle into which it discharges. (b) Size. The minimum required air gap shall be twice the effective opening of a potable water outlet unless the outlet is a distance less than three times the effective opening away from a wall or similar vertical surface in which cases, the minimum required air gap shall be three times the effective opening of the outlet. In no case shall the minimum required air gap be less than shown in Table 12.1.