§ 1205.7 — DIELECTRIC PROTECTION
Atlanta City Code (Code of Ordinances, Part II) (Supp. No. 108, Update 1: codified through Ordinance No. 2026-37 (26-O-1511), enacted September 30, 2026) · Atlanta Land Development Code, App. C, ch. I, § 1205.7
Corpus is an independent public-information project, not the official City of Atlanta website. Stable reference: corpuslaw.us/code/6fa924fd-e156-4158-b786-3931d425f2e0
1205.7. - DIELECTRIC PROTECTION
(1) Galvanized steel service-piping that is connected to copper-based distribution piping shall be protected from the junctions of the dissimilar metals. (2) Iron-based safety and control devices that are installed in copper-based piping, or on copper-based vessels, shall be protected from accelerated corrosion by installing dielectric fittings between the dissimilar metals. (3) When galvanized piping is connected to copper-based vessels, the steel piping shall be protected from accelerated corrosion by installing dielectric fittings at the connection(s). (4) Copper-based safety and control devices may be installed in galvanized piping, or on iron-based vessels, without dielectric fittings, provided they are of the copper devices exposed to water is not more than five percent of the area of the galvanized pipe, or the iron-based vessel, also exposed to water. (5) When copper-based is connected to iron-based vessels, the iron vessels shall be protected from accelerated corrosion by installing dielectric fittings at the connection(s). (6) Piping, vessels, and safety/control devices that consist of stainless steel, monel, or similar alloys, shall be deferred to corrosion engineer for dielectric-protection guidance. (7) All dielectric fittings used on plumbing systems shall have a rated working pressure not less than the pressure setting of water heater safety relief valve and a corresponding temperature rating not less than 210°F. SECTION 7: That Chapter 14 entitled Vents and Venting, be amended as follows: 1. That Section 1414.1 entitled Battery Venting be deleted in its entirety and the following substituted in lieu thereof: "A branch soil or waste pipe of uniform diameter throughout its length to which are connected a minimum of three (3) but not more than eight (8) water closets with a total connected load not exceeding 50% of the fixture units allowed by column two of Table 1305.2 may be vented by a circuit or loop vent system which shall be connected in front of the last upstream fixture drain. In addition, lower-floor battery vented branches shall be provided with a relief vent connect in front of the first fixture connection. Shower stalls or floor drains may be connected to the horizontal branch but must be vented separately. When lavatories or similar fixtures having a fixture unit rating of four or less and a maximum 2-inch fixture drain discharge from above such branches, each vertical branch shall be provided with a continuous vent. Fixtures having fixture unit ratings greater than four shall not discharge into such branch from above unless all fixtures in the battery group are individually vented. Fixtures from an upper floor shall not discharge into a battery vented branch." 2. That Section 1414 entitled Circuit and Loop Venting, Sub-section 1414.3.3, be modified as follows: 1414.3.3 Fixtures, other than water closets, connected to a circuit and loop venting system horizontal branch through a wye and one-eight bend installed in a horizontal position shall be individually vented. SECTION 8: That Chapter 16 entitled Alternate Designed Plumbing Systems, be amended as follows: 1. That Section 1603 entitled Single Stack Plumbing Systems, be deleted in its entirety without substitution. SECTION 9: That Appendices H and J be deleted in their entirety without substitution: SECTION 10: That Appendices A, B, C, E, F, G, and I be adopted in their entirety without amendment. SECTION 11: That Appendix K entitled illustrations, be deleted in its entirety and substitute the following in lieu thereof:
Ask a question about Atlanta law
Corpus searches the Atlanta sections it holds and shows the ones that match, with their citations. Free, no sign-in.