1300.7. - Downspouts, Rain Leaders and Piping.

(a) Except for first-flush diverters, no section of piping shall be installed in a manner that will hold water and not drain completely. All sections of wet piping shall be drainable. Trapping of piping is prohibited. (b) Metal rain leaders shall be seamless aluminum or be coated with an approved non-toxic material. Copper and lead-bearing soldered joints are prohibited. (c) Piping from downspouts shall be a minimum of two inches interior diameter. Piping into the storage tanks shall be a minimum of three inches interior diameter. The overflow device shall consist of a pipe three inches in diameter minimum or a pipe with a cross sectional area equal to or greater than the total of all downspouts. (d) There shall he no direct connection of any rainwater catchment pipe system and any domestic potable water pipe system without an approved backflow prevention device.

(Ord. No. 2011-43(11-O-0740), § 1, 9-28-11)