§ 1300.9 — Storage Tanks

Atlanta City Code (Code of Ordinances, Part II) (Supp. No. 108, Update 1: codified through Ordinance No. 2026-37 (26-O-1511), enacted September 30, 2026) · Atlanta Land Development Code, App. C, ch. I, § 1300.9

Corpus is an independent public-information project, not the official City of Atlanta website. Stable reference: corpuslaw.us/code/67eacf27-83ab-4996-b5f2-2bf922d14254

1300.9. - Storage Tanks.

(a) Above ground storage tanks shall be opaque or painted to prohibit algae growth. (b) Storage tanks shall be listed for use with potable water in accordance with NSF/ANSI 61, including liners or epoxy coatings when specified. Storage tanks that have been previously used for other purposes or manufactured from recycled materials are prohibited. Storage tanks shall be completely covered and any vent or other opening screened to prevent mosquito breeding. Covers shall be sturdy and constructed in such a way that they will not allow water to pond or collect on the surface. Covers shall be adequately secured to prevent unauthorized access. (c) Storage tanks shall provide adequate access for cleaning and maintenance purposes. (d) Storage tanks shall be as close to the catchment area as is practical and protected from direct sunlight in an approved manner. Adequate protections shall be implemented to protect the tank and connected piping from freezing. (e) Storage tanks shall be provided with an overflow equal or greater in size to the tank inlet. Overflows shall be piped away from the tank and the water shall be disposed of in a manner that will not cause damage to property or erosion. Overflow drains shall be equipped with durable animal guards or screens. The discharge location of the overflow water shall be in accordance with City of Atlanta Codes and ordinances. (f) Above ground storage tanks shall be placed on a stable, level surface of sufficient strength to accommodate the size and weight of a full tank. (g) Buried plastic storage tanks shall be reinforced and able to withstand the weight of the surrounding fill and soil and full capacity of water. Underground tanks shall also have physical protection from surface water intrusion. Concrete tanks which are above ground or underground shall be constructed to withstand the load of water capacity and any other applicable structural forces. (h) Tanks shall be vented. The vent shall be equipped with a screen with no opening greater than one-sixteenth inch (approximately 2 mm).

(Ord. No. 2011-43(11-O-0740), § 1, 9-28-11)

Ask a question about Atlanta law

Corpus searches the Atlanta sections it holds and shows the ones that match, with their citations. Free, no sign-in.