§ 1300.12 — Water Treatment
Atlanta City Code (Code of Ordinances, Part II) (Supp. No. 108, Update 1: codified through Ordinance No. 2026-37 (26-O-1511), enacted September 30, 2026) · Atlanta Land Development Code, App. C, ch. I, § 1300.12
Corpus is an independent public-information project, not the official City of Atlanta website. Stable reference: corpuslaw.us/code/51887a91-80e0-4307-9007-7518b2bded15
1300.12. - Water Treatment.
(a) All potable rainwater catchment systems shall be treated to prevent sediment and water borne organisms that may exist from reaching the end point of use. Treatment shall occur between the storage tank and point of end use. (b) Sediment filtration of five microns or less shall be provided for reduction of contaminants that may mask bacteria or cloud the water before disinfection. All filters shall be of adequate size to extend service time. Cartridge filter elements shall be replaced as recommended by the manufacturer. All filters shall be NSF/ANSI 51: Food Equipment Materials (plastics, materials and components used in food equipment). (c) Carbon filtration shall be provided for improving taste and reduction of odor and organic chemicals. All filters shall be NSF/ANSI 51. (d) All filtration shall be installed before disinfection systems according to manufacturer's recommendations. Filtration and disinfection systems shall be located as close to the final point of use as possible. (e) Following the above filters an automatic disinfection device either chemical injection, ozone generators, or ultraviolet (UV) light shall be installed. (f) If ozone generators are used, provisions shall be made for venting per manufacturer recommendations. (g) UV light systems shall be sized based upon the maximum rated flow. UV lamps shall be maintained as per the manufacturers requirements but shall be replaced after not more than 10,000 hours of operation. UV light systems shall have a bulb life monitor that provides some indication when the bulb life is dying or dead. NSF/ANSI 55 standard for Class A UV treatment systems or units with comparable performance capabilities are recommended for UV light systems. Ozone generators or chorine pump injectors shall be sized and maintained as per the manufacturer's recommendation. A failsafe in any automatic unit is recommended to shut off a valve, preventing water flow if any fault occurs in the unit. (h) Installation of a manual city water hand valve after the backflow prevention device is recommended to be able to switch to city water in the event of a power outage.
(Ord. No. 2011-43(11-O-0740), § 1, 9-28-11)
Ask a question about Atlanta law
Corpus searches the Atlanta sections it holds and shows the ones that match, with their citations. Free, no sign-in.