Sec. 15.01.580. - Chapter 10, Section 1018.5 amended—Aisles in other than assembly spaces and Group B and M.
Chapter 11, Section 1018.5 of the International Fire Code, 2024 Edition, is amended to read as follows: 1018.5 Aisles in other than assembly spaces and Group B and M In other than rooms or spaces used for assembly purposes and Group B and M occupancies, the minimum clear aisle capacity shall be determined by Section 1005.1 for the occupant load served, but the width shall be not less than that required for corridors by Section 1020.3. Exception: Nonpublic aisles serving less than 50 people and not required to be accessible by the Americans with Disabilities Act ("ADA") need not exceed 28 inches (711 mm) in width.
(Ord. No. 52-878, § 58, 1-13-26)