§ 15.01.450 — Chapter 10, Section 1010.1.1 amended—Size of doors
The Code of the City of Wichita, Kansas (Supp. No. 36, Update 1: codified through Ordinance No. 53-088, adopted July 28, 2026) · Wichita City Code § 15.01.450
Corpus is an independent public-information project, not the official City of Wichita website. Stable reference: corpuslaw.us/code/f443dad6-7170-48b0-834a-d2d03470a648
Sec. 15.01.450. - Chapter 10, Section 1010.1.1 amended—Size of doors.
Chapter 10, Section 1010.1.1 of the International Fire Code, 2024 Edition, is amended to read as follows: 1010.1.1 Size of doors The required capacity of each door opening shall be sufficient for the occupant load thereof and shall provide a minimum clear opening width of 32 inches (813 mm). The clear opening width of doorways with swinging doors shall be measured between the face of the door and the frame stop, with the door open 90 degrees (1.57 rad). Where this section requires a minimum clear opening width of 32 inches (813 mm) and a door opening includes two door leaves without a mullion, one leaf shall provide a minimum clear opening width of 32 inches (813 mm). In Group I-2, doors serving as means of egress doors where used for the movement of beds shall provide a minimum clear opening width of 41½ inches (1,054 mm). The minimum clear opening height of doors shall be not less than 80 inches (2,032 mm). Exceptions: 1. In Group R-2 and R-3 dwelling and sleeping units that are not required to be an Accessible unit, Type A unit or Type unit, the minimum width shall not apply to door openings that are not part of the required means of egress. 2. In Group I-3, door openings to resident sleeping units that are not required to be an Accessible unit shall have a minimum clear opening width of 32 inches (813 mm). 3. Door openings to storage closets less than 10 square feet (0.93 m 2 ) in area shall not be limited by the minimum clear opening width. 4. Door openings within a dwelling unit or sleeping unit shall have a minimum clear opening height of 78 inches (1,881 mm). 5. In dwelling and sleeping units that are not required to be Accessible, Type A or Type B units, exterior door openings other than the required exit door shall have a minimum clear opening height of 76 inches (1,930 mm). 6. In Groups I-1, R-2, R-3 and R-4, in dwelling and sleeping units that are not required to be Accessible, Type A or Type B units, the minimum clear opening widths shall not apply to interior egress doors. 7. Door openings required to be accessible with Type B units intended for user passage shall have a minimum clear opening width of 32 inches (813 mm). 8. Doors serving sauna compartments, toilet compartments or dressing, fitting or changing compartments that are not required to be accessible shall have a minimum clear opening width of 20 inches (508 mm).
(Ord. No. 52-878, § 45, 1-13-26)
Ask a question about Wichita law
Corpus searches the Wichita sections it holds and shows the ones that match, with their citations. Free, no sign-in.