§ 15.01.560 — Section 1015.2 amended—Where required
The Code of the City of Wichita, Kansas (Supp. No. 36, Update 1: codified through Ordinance No. 53-088, adopted July 28, 2026) · Wichita City Code § 15.01.560
Corpus is an independent public-information project, not the official City of Wichita website. Stable reference: corpuslaw.us/code/edc9654e-36a1-44f2-a0ec-d71922e721cd
Sec. 15.01.560. - Section 1015.2 amended—Where required.
Chapter 10, Section 1015.2 of the International Fire Code, 2024 Edition, is amended to read as follows: 1015.2 Where required Guards shall be located along open-sided walking surfaces, such as mezzanines, equipment platforms, aisles, stairs, ramps and landings that are located more than 30 inches (762 mm) measured vertically to the floor or grade below at any point within 36 inches (914 mm) horizontally to the edge of the open side and at the perimeter of occupiable roofs. Guards shall be adequate in strength and attachment in accordance with Section 1607.9. Exceptions: Guards are not required for the following locations: 1. On the loading side of loading docks or piers. 2. On the audience side of stages and raised platforms, including stairs leading up to the stage and raised platforms. 3. On raised stage and platform floor areas, such as runways, ramps and side stages used for entertainment or presentations. 4. At vertical openings in the performance area of stages and platforms. 5. At elevated walking surfaces appurtenant to stages and platforms for access to and utilization of special lighting or equipment. 6. Along vehicle service pits not accessible to the public. 7. In assembly seating areas at cross aisles in accordance with Section 1030.17.2. 8. On the loading side of station platforms on fixed guideway transit or passenger rail systems. 9. Portions of an occupiable roof located less than 30 inches (762 mm) measured vertically to adjacent unoccupiable roof areas where approved guards are present at the perimeter of the roof. 10. At portions of an occupiable roof where an approved barrier is provided. 11. At window wells a protective cover designed to meet the amended roof live load requirements of Chapter 16 of the International Building Code may be substituted for guards. The window well covers shall be provided with an emergency egress hatch located above the ladder or stairway, with the minimum egress opening maintained. The force required to open the egress hatched shall not exceed 30 pounds (133.45 N). Window well covers and gates shall be constructed of materials approved for exterior use.
(Ord. No. 52-878, § 56, 1-13-26)
Ask a question about Wichita law
Corpus searches the Wichita sections it holds and shows the ones that match, with their citations. Free, no sign-in.