For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 15.01.510 — Section 1012.6.3 amended—Length

The Code of the City of Wichita, Kansas (Supp. No. 36, Update 1: codified through Ordinance No. 53-088, adopted July 28, 2026) · Wichita City Code § 15.01.510

Corpus is an independent public-information project, not the official City of Wichita website. Stable reference: corpuslaw.us/code/6f3eaa0b-bc83-425d-9624-a5ed4e053bc7

Sec. 15.01.510. - Section 1012.6.3 amended—Length.

Chapter 10, Section 1012.6.3 of the International Fire Code, 2024 Edition, is amended to read as follows: 1012.6.3 Length The landing length shall be 60 inches (1,525 mm) minimum. Exceptions: 1. In Group R-2 and R-3 individual dwelling and sleeping units, landings are permitted to be 36 inches (914 mm) minimum. 2. Where the ramp is not part of an accessible route, the length of the landing shall not be required to be more than 48 inches (1219 mm) in the direction of travel. 3. The minimum clear opening width shall not apply to doors for nonassessable shower or sauna compartments. 4. The minimum clear opening width shall not apply to the doors for no accessible toilet stalls.

(Ord. No. 52-878, § 51, 1-13-26)

Ask a question about Wichita law

Corpus searches the Wichita sections it holds and shows the ones that match, with their citations. Free, no sign-in.