§ 15.01.460 — Chapter 10, Section 1010.1.4 amended—Floor elevation

The Code of the City of Wichita, Kansas (Supp. No. 36, Update 1: codified through Ordinance No. 53-088, adopted July 28, 2026) · Wichita City Code § 15.01.460

Corpus is an independent public-information project, not the official City of Wichita website. Stable reference: corpuslaw.us/code/1945c20c-e2de-4b51-bb48-e5179f07ffa7

Sec. 15.01.460. - Chapter 10, Section 1010.1.4 amended—Floor elevation.

Chapter 10, Section 1010.1.4, of the International Fire Code, 2024 Edition, is amended to read as follows: 1010.1.4 Floor elevation There shall be a floor or landing on each side of a door. Such floor or landing shall be at the same elevation on each side of the door. Landings shall be level except for exterior landings, which are permitted to have a slope not to exceed 0.25 unit vertical in 12 unit's horizontal (2-percent slope). Exceptions: 1. At doors serving individual dwelling units or sleeping units in R-2 and R-3, a door is permitted to open at the top step of an interior flight of stairs, provided that the door does not swing over the top step. 2. At exterior doors serving Groups F, H, R-2 and S and where such doors are not part of accessible route, the landing at an exterior door shall not be more than 7 inches (178 mm) below the landing on the egress side of the door, provided that the door, other than an exterior storm or screen door, does not swing over the landing. 3. At exterior doors serving Group U and individual dwelling units and sleeping units in Groups R-2 and R-3, and where such units are not required to be Accessible units, Type A units or Type B units, the landing at an exterior doorway shall be not more than 7¾ inches (197 mm) below the landing on the egress side of the door. Such doors, including storm or screen doors, shall be permitted to swing over either landing. Exceptions: 1. Storm or screen doors are permitted to swing over exterior flight of stairs. 2. An exterior door is permitted to open at the top step of an exterior flight of stairs from a patio, provided there no more than four risers. 4. Variations in elevation due to differences in finish materials, but not more than ½ inch (12.7 mm). 5. Exterior decks, patios or balconies that are part of Type B dwelling units or sleeping units, that have impervious surfaces and that are not more than 4 inches (102 mm) below finish floor level of the adjacent interior space of the dwelling unit or sleeping unit. 6. Doors, gates, and panels that serve as access points to building equipment rooms that are not normally occupied, except where serving the following: 6.1 Rooms containing electrical equipment rated 800 amperes or more that contain overcurrent devices, switching devices or control devices and where the exit or exit access door is less than 25 feet (7,620 mm) from the equipment working space as required by NFPA 70. See section 1010.2.8.2. 6.2 Rooms or spaces having floor area larger than 1,000 square feet (93 m 2 ), containing a refrigerant evaporator and maintained at a temperature below 68°F (20°C). See Section 1006.2.2.3.

(Ord. No. 52-878, § 46, 1-13-26)

Ask a question about Wichita law

Corpus searches the Wichita sections it holds and shows the ones that match, with their citations. Free, no sign-in.