§ 15.01.480 — Chapter 10, Section 1011.5.2 amended—Riser height and tread depth
The Code of the City of Wichita, Kansas (Supp. No. 36, Update 1: codified through Ordinance No. 53-088, adopted July 28, 2026) · Wichita City Code § 15.01.480
Corpus is an independent public-information project, not the official City of Wichita website. Stable reference: corpuslaw.us/code/bf87f6d2-67a7-416a-a7ed-ae2f2a6fcfd9
Sec. 15.01.480. - Chapter 10, Section 1011.5.2 amended—Riser height and tread depth.
Chapter 10, Section 1011.5.2 of the International Fire Code, 2024 Edition, is incorporated to read as follows: 1011.5.2 Riser height and tread depth Stair riser heights shall be 7 inches (178 mm) maximum and 4 inches (102 mm) minimum. The riser height shall be measured vertically between the nosings of adjacent treads or between the stairway landing and the adjacent tread. Rectangular tread depths shall be 11 inches (279 mm) minimum measured horizontally between the vertical planes of the foremost projection of adjacent treads and at a right angle to the tread's nosing. Winder treads shall have a minimum tread depth of 11 inches (279 mm) between the vertical planes of the foremost projection of adjacent treads at the intersections with the walk line and a minimum tread depth of 10 inches (254 mm) within the clear width of the stair. Exceptions: 1. Spiral stairways in accordance with Section 1011.10. 2. Stairways connecting stepped aisles to cross aisles or concourses shall be permitted to use the riser/tread dimension in Section 1030.14.2. 3. In Group R-3 occupancies; within dwelling units in Group R-2 occupancies; and in Group U occupancies that are accessory to a Group R-3 occupancy or accessory to individual dwelling units in Group R-2 occupancies; the maximum riser height shall be 7¾ inches (197 mm); the minimum tread depth shall be 10 inches (254 mm); the minimum winder tread depth at the walk line shall be 10 inches (254 mm); and the minimum winder tread depth shall be 6 inches (152 mm). A nosing projection not less than ¾ inches (19.1 mm) but not more than 1¼ inches (32 mm) shall be provided on stairways with solid risers where the tread depth is less than 11 inches (297 mm). 4. See Section 503.1 of the International Existing Building Code for the replacement of existing stairways. 5. In Group 1-3 facilities, stairways providing access to guard towers, observation stations and control rooms, not more than 250 square feet (23 m 2 ) in area, shall be permitted to have a maximum riser height of 8 inches (203 mm) and minimum tread of 9 inches (229 mm).
(Ord. No. 52-878, § 48, 1-13-26)
Ask a question about Wichita law
Corpus searches the Wichita sections it holds and shows the ones that match, with their citations. Free, no sign-in.