§ 15.01.590 — Chapter 10, Section 1020.2 amended—Construction

The Code of the City of Wichita, Kansas (Supp. No. 36, Update 1: codified through Ordinance No. 53-088, adopted July 28, 2026) · Wichita City Code § 15.01.590

Corpus is an independent public-information project, not the official City of Wichita website. Stable reference: corpuslaw.us/code/12ed5ab0-a013-49d2-8946-0e389540a398

Sec. 15.01.590. - Chapter 10, Section 1020.2 amended—Construction.

Chapter 10, Section 1020.2 of the International Fire Code, 2024 Edition, is amended to read as follows: 1020.2 Construction Corridors shall be fire-resistance rated in accordance with Table 1020.2. The corridor walls required to be fire-resistance rated shall comply with Section 708 for fire partitions. Exceptions: 1. A fire-resistance rating is not required for corridors in an occupancy in Group E where each room that is used for instruction has not less than one door opening directly to the exterior and rooms for assembly purposes have not less than one-half of the required means of egress doors opening directly to the exterior. Exterior doors specified in this exception are required to be at ground level. 2. A fire-resistance rating is not required for corridors contained within a dwelling unit or sleeping unit in an occupancy in Groups I-1 and R. 3. A fire-resistance rating is not required for corridors in open parking garages. 4. A fire-resistance rating is not required for corridors in an occupancy in Group B that is a space requiring only single means of egress complying with Section 1006.2. 5. Corridors adjacent to the exterior walls of buildings shall be permitted to have unprotected openings on unrated exterior walls where unrated wall are permitted by Table 705.5 and unprotected openings are permitted by Table 705.9. 6. A fire-resistance rating is not required for corridors not exceeding 20 feet (6,096 mm) in length, when they provide direct, obvious and unobstructed means of travel to an exit or until egress is provided from the building, provide that all openings, except the entrance to the corridor, are protected with self-closing doors of non-combustible construction or solid wood core, not less than 1 inch (335 mm) in thickness or fixed glazing. Use of rolling or sliding doors shall not be permitted, unless equipped with a closing device which operates with the actuation of an approved listed smoke detector.

(Ord. No. 52-878, § 59, 1-13-26)

Ask a question about Wichita law

Corpus searches the Wichita sections it holds and shows the ones that match, with their citations. Free, no sign-in.