§ 3.03 — Amendments to the International Existing Building Code, 2021 edition
Code of Ordinances of the City of Allen, Texas (Codified through Ordinance No. 4212-2-26, adopted February 10, 2026 (Supp. No. 23)) · Allen Land Development Code § 3.03
Corpus is an independent public-information project, not the official City of Allen website. Stable reference: corpuslaw.us/code/6c237947-8a2a-415a-b013-714d17a3375d
Sec. 3.03 - Amendments to the International Existing Building Code, 2021 edition.
The following amendments to the International Existing Building Code, 2021 edition, as adopted pursuant to section 3.01, are hereby adopted: 1. Section 102.4 is amended to read as follows: (A)102.4 Referenced codes and standards. The codes, when specifically adopted, and standards referenced in this code shall be considered part of the requirements of this code to the prescribed extent of each such reference and as further regulated in Sections 102.4.1 and 102.4.2. 2. Section 202 is amended by amending the definitions of "Existing Building" and "Existing Structure" to read as follows: Existing Building - A building, structure, or space, with an approved final inspection issued under a code edition which is at least 2 published code editions preceding the currently adopted building code; a building, structure or space that is undergoing a change of use or a change of occupancy. Existing Structure - A building, structure, or space, with an approved final inspection issued under a code edition which is at least 2 published code editions preceding the currently adopted building code; a building, structure or space that is undergoing a change in use or a change of occupancy. 3. Section 30 6.1 is amended by adding a paragraph titled "Exception" to read as follows: Exception: Components of projects regulated by and registered with Architectural Barriers Division of Texas Department of Licensing and Regulation shall be deemed to be incompliance with the requirements of this chapter. 4. Section 401.3 is deleted. 5. Section 405.2.5 is deleted. 6. Section 406.1 is amended to read as follows: 406.1 Material. Existing electrical wiring and equipment undergoing repair shall be allowed to be repaired or replaced with like material, in accordance with the requirements of NFPA 70. 7. Section 502.3 is deleted. 8. Section 504.1.2 is amended to read as follows: 504.1.2 Existing fire escapes. Existing fire escapes shall continue to be accepted as a component in the means of egress in existing buildings only. Existing fire escapes shall be permitted to be repaired or replaced. 9. Section 504.1.3 is deleted. 10. Section 507.3 is deleted. 11. Section 701.3 is deleted. 12. Section 702.7 is amended to read as follows: 702.7 Materials and methods. All new work shall comply with the materials and methods requirements in the International Building Code, International Energy Conservation Code, International Mechanical Code, National Electrical Code, International Fuel Gas Code, and International Plumbing Code, as applicable, that specify material standards, detail of installation and connection, joints, penetrations, and continuity of any element, component, or system in the building. 13. Section 802.5.1 is amended to read as follows: 802.5.1 Minimum requirement. Every portion of open-sided walking surfaces, including mezzanines, equipment platforms, aisles, stairs, ramps and landings that are not provided with guards, or those in which the existing guards are judged to be in danger of collapsing, shall be provided with guards. 14. Section 803.1 is amended by adding the following sentence: For the purpose of fire sprinkler protection and fire alarm requirements included in this section, the work area shall be extended to include at least the entire tenant space or spaces bounded by walls capable of resisting the passage of smoke containing the subject work area, and if the work area includes a corridor, hallway, or other exit access, then such corridor, hallway, or other exit access shall be protected in its entirety on that particular floor level. 15. Section 803.3 is amended to read in its entirety as follows: 803.3 Standpipes. Refer to Section 1103.6 of the Fire Code for retroactive standpipe requirements. 16. Section 804.2 is amended by deleting Exception 1. 17. Section 804.4.1.2 is amended to read as follows: 804.4.1.2 Fire escapes required. For other than Group 1-2, where more than one exit is required an existing fire escape complying with Section 804.4.1.2.1 shall be accepted as providing one of the required means of egress. 18. Section 80 4.1.2.1 is amended as follows: a. Numbered paragraph 2 is amended to read as follows: 2. Access to a fire escape shall be through a door. b. Numbered paragraph 3 is deleted. c. Numbered paragraph 5 is amended to read as follows: 5. In all building of Group E occupancy up to and including the 12 th grade, buildings of Group I occupancy, boarding houses, and childcare centers, ladders of any type are prohibited on fire escapes used as a required means of egress. 19. Section 804.6.2 Transoms is amended to read as follows: 804.6.2 Transoms. In all buildings of Group B, E, I-1, R-1, and R-2 occupancies … (remainder unchanged) 20. Section 904.1 is amended by adding the following sentence: For the purpose of fire sprinkler protection and fire alarm requirements included in this section, the work area shall be extended to include at least the entire tenant space or spaces bounded by walls containing the subject work area, and if the work area includes a corridor, hallway, or other exit access, then such corridor, hallway, or other exit access shall be protected in its entirety on that particular floor level. 21. Section 904.1.1 is amended to read as follows: 904.1.1 High-rise buildings. An automatic sprinkler system shall be provided in work areas of high-rise buildings. 22. Section 1103.3 is deleted. 23. Section 1201.4 is deleted. 24. Section 1301.3.2 is amended to read as follows: 1301.3.2 Compliance with other codes. Buildings that are evaluated in accordance with this section shall comply with the International Fire Code. 25. Section 1301.3.3 is deleted. 26. Section 1402.6 is deleted. 27. Section 1509 is amended to delete 1509.1 through 1509.5 and add Section 1509.1 to read as follows: 1509.1 When required. An approved water supply for fire protection, either temporary or permanent, shall be made available as soon as combustible material arrives on site. The water supply design and the timing of water supply installation relative to building construction shall comply with the adopted Fire Code.
(Ord. No. 3919-6-22, § 1, 6-14-2022)
Ask a question about Allen law
Corpus searches the Allen sections it holds and shows the ones that match, with their citations. Free, no sign-in.