§ 3.09 — Amendments to National Electrical Code, 2020 edition
Code of Ordinances of the City of Allen, Texas (Codified through Ordinance No. 4212-2-26, adopted February 10, 2026 (Supp. No. 23)) · Allen Land Development Code § 3.09
Corpus is an independent public-information project, not the official City of Allen website. Stable reference: corpuslaw.us/code/46ff8d04-5f06-4d73-95b8-3a97674be0f0
Sec. 3.09. - Amendments to National Electrical Code, 2020 edition.
The following amendments to the National Electrical Code, 2020 edition, as adopted pursuant to section 3.01 are hereby adopted. 1. Article 90.4 is amended by adding section 90.4.1 to read as follows: Article 90.4.1 Administration and enforcement. Fees for the issuance of permits and performance of inspections as required by this code shall be as established from time to time by resolution of the City Council and set forth in the City's Fee Schedule. There shall be a re-inspection fee, as set forth in the City's Fee Schedule, where it is necessary for the electrical inspector to re-inspect any phase of an electrical job. 2. Article 100, Part 1, is amended by adding the definitions of "Engineering Supervision" to read as follows: Engineering Supervision. Supervision by a Qualified State of Texas Licensed Professional Engineer engaged primarily in the design or maintenance of electrical installations. 3. Article 110.2 is amended to read as follows: 110.2 Approval. The conductors and equipment required or permitted by this Code shall be acceptable only if approved. Approval of equipment may be evident by listing and labeling of equipment by a Nationally Recognized Testing Lab (NRTL) with a certification mark of that laboratory or a qualified third-party inspection agency approved by the AHJ. Exception: Unlisted equipment that is relocated to another location within a jurisdiction or is field modified is subject to the approval by the AHJ. This approval may be by a field evaluation by a NRTL, or qualified third-party inspection agency approved by the AHJ. Informational Note No. 1: See 90.7, Examination of Equipment for Safety, and 110.3, Examination, Identification, Installation, and Use of Equipment. See definitions of Approved, Identified, Labeled, and Listed. Informational Note No. 2: Manufacturer's self-certification of equipment may not necessarily comply with US product safety standards as certified by a Nationally Recognized Testing Lab. Informational Note No. 3: NFPA 790, and 791 provide an example of an approved method for qualifying a third-party inspection agency. 4. Article 210.52(G)(1) is amended to read as followed: (1) Garages. In each attached garage and in each detached garage with electric power, at least one receptacle outlet shall be installed for each car space. 5. Article 300.1(A) is amended to read as follows: 300.1(A) All Wiring Installations. This Article covers general questions requirements for wiring methods and materials for all wiring installations unless modified by other articles. All electrical conductors for commercial, office, or industrial installation shall be installed in approved conduits or raceways, regardless of type of construction. 1. No electrical panels or plastic electrical boxes shall be mounted on the opposite sides of the walls around bathtubs and shower enclosures, and Romex in such locations shall be enclosed in metal conduit around bath areas; 2. Smoke detectors (alarms), carbon monoxide alarms, GFCI and AFI protection shall be updated at time-of-service upgrade or remodel; and 3. All commercial structures that are framed in wood material shall be wired in either MC cable or conduit. 6. Article 300.11 is amended by adding Paragraph (C) to read as follows: (C) All ceiling grid lights shall be supported to structural framing of the building and not to the grid into which they are laid. 7. Article 330.1 is amended to read as follows: 330.1 Scope. This article covers the use, installation, and construction specifications of metal-clad cable, Type MC. All metal clad cable installations shall install insulated bushings such as red devils. 8. Article 500.8(A)(3) is amended to read as follows: (A)(3) Evidence acceptable to the authority having jurisdiction such as a manufacturer's self-evaluation or an engineering judgment signed and sealed by a Qualified State of Texas Licensed Professional Engineer engaged primarily in the design or maintenance of electrical installations. 9. Article 505.7(A) is amended to read as follows: (A) Implementation of Zone Classification System. Classification of areas, engineering and design, selection of equipment and wiring methods, installation, and inspection shall be performed by a Qualified State of Texas Licensed Professional Engineer engaged primarily in the design or maintenance of electrical installations. 10. Article 517.30(G) is amended to read as follows: (G) Coordination. Overcurrent protection devices serving the equipment branch of the essential electrical system shall be coordinated for the period of time that a fault's duration extends beyond 0.1 second. Exception No. 1: Between transformer primary and secondary overcurrent protective devices, where only one overcurrent protective device or set of overcurrent protective devices exists on the transformer secondary. Exception No. 2: Between overcurrent protective devices of the same size (ampere rating) in series. Informational Note: The terms coordination and coordinated as used in this section do not cover the full range of overcurrent conditions. Informational Note: the terms coordination and coordinated as used in this section do not cover the full range of overcurrent conditions. 11. Article 700 is amended by adding Article 700.27 to read as follows: Article 700.27 Wiring of Emergency Light Fixtures and Locations. 1. Battery pack fixtures must be wired to the normal lighting circuit where they are installed. The battery pack shall be tied onto the hot leg of the room switch. Where room switches are not provided and lights are turned off at the breaker switch, it shall be necessary to provide a light switch at the breaker control panel, wiring the fixtures as previously described. Permanent identification of a RED circular mark at the breaker located in the electrical panel box; 2. Where battery pack florescent fixtures are installed on a security light circuit which remains on at all times, it is not necessary to wire through a control switch provided the breaker is locked in the on position. All other installations shall be wired in the same manner as battery pack incandescent fixtures; 3. Where large open areas are lighted with two or more circuits, it shall be necessary to wire each emergency light fixture to the nearest lighting circuit; 4. All bathrooms including male, female and family. Also, all Fire Riser and Command Rooms; and 5. All Emergency and Exit Lights shall be installed according to the drawings and shall be field verified meeting all code requirements and additional lighting may be required.
(Ord. No. 3919-6-22, § 1, 6-14-2022)
Ask a question about Allen law
Corpus searches the Allen sections it holds and shows the ones that match, with their citations. Free, no sign-in.
