§ 3.08 — Amendments to the International Plumbing Code, 2021 edition
Code of Ordinances of the City of Allen, Texas (Codified through Ordinance No. 4212-2-26, adopted February 10, 2026 (Supp. No. 23)) · Allen Land Development Code § 3.08
Corpus is an independent public-information project, not the official City of Allen website. Stable reference: corpuslaw.us/code/f501b84b-ce72-453b-b17d-3e452c66cd8c
Sec. 3.08. - Amendments to the International Plumbing Code, 2021 edition.
The following amendments to the International Plumbing Code, 2021 edition, as adopted pursuant to section 3.01, are hereby adopted: 1. Table of Contents Chapter 7, Section 713 is amended to read as follows: 713. Registered Professional Engineer Drainage Design. 2. Section 102.8 is amended to read as follows: 102.8 Referenced codes and standards. The codes and standards referenced in this code shall be those that are listed in Chapter 15 and such codes, when specifically adopted, and standards shall be considered as part of the requirements of this code to the prescribed extent of each such reference. Where the differences occur between provisions of this code and the referenced standards, the provisions of this code shall be the minimum requirements. Whenever amendments have been adopted to the referenced codes and standards, each reference to said code and standard shall be considered to reference the adopted amendments as well. Any reference to NFPA 70 or the ICC Electrical Code shall mean the Electrical Code as adopted. 3. Sections 109.2, and 109.5 are amended to read as follows: 109.2 Fee schedule. Fees for the issuance of permits and performance of inspections as required by this code shall be as established from time to time by resolution of the City Council and set forth in the City's Fee Schedule. 109.5 Fee refunds. The building official shall establish a policy for authorizing the refunding of fees. 4. Section 114 is amended in its entirety to read as follows: SECTION 114 MEANS OF APPEAL 114.1 Application for appeal. Any person shall have the right to appeal a decision of the building official to the Board of Adjustment as provided in Section 2.02 of the Allen Land Development Code. 5. Section 305.1 is amended to read as follows: 305.1 Protection against contact. Metallic piping, except for cast iron, ductile iron and galvanized steel, shall not be placed in direct contact with steel framing members, concrete or cinder walls and floors or other masonry. Metallic piping shall not be placed in direct contact with corrosive soil. Where sheathing is used to prevent direct contact, the sheathing shall have a thickness of not less than 0.008 inch (8 mil) (0.203 mm) and the sheathing shall be made of approved material. Where sheathing protects piping that penetrates concrete or masonry walls or floors, the sheathing shall be installed in a manner that allows movement of the piping within the sheathing. 6. Section 305.4.1 is amended to read as follows: 305.4.1 Sewer depth. Building sewers shall be a minimum of 12 inches (304 mm) below grade. 7. Section 305.7 is amended to read as follows: 305.7 Protection of components of plumbing system. Components of a plumbing system installed within 3 feet along alleyways, driveways, parking garages or other locations in a manner in which they could be exposed to damage shall be recessed into the wall or otherwise protected in an approved manner. 8. Section 306 is amended by adding Section 306.2.4 to read as follows: 306.2.4 Plastic sewer and DWV piping installation. Plastic sewer and DWV piping installed underground shall be installed in accordance with the manufacturer's installation instructions. Trench width shall be controlled to not exceed the outside the pipe diameter plus 16 inches or in a trench which has a controlled width equal to the nominal diameter of the diameter of the piping multiplied by 1.25 plus 12 inches. The piping shall be bedded in 4 inches of granular fill and then backfilled compacting the side fill in 6-inch layers on each side of the piping. The compaction shall be to minimum of 85 percent standard proctor density and extend to a minimum of 6 inches above the top of the pipe. All PBVC shall be schedule 40 with No Foam or Cell Core Allowed. 9. Sections 314.2.1 is amended to read as follows: 314.2.1 Condensate disposal. Condensate from all cooling coils and evaporators shall be conveyed from the drain pan outlet to an approved place of disposal (intervening text unchanged) Condensate shall not discharge into a street, alley, sidewalk, rooftop, or other areas so as to cause a nuisance. 10. Section 409.2 is amended to read as follows: 409.2 Water connection. The water supply to a commercial dishwashing machine shall be protected against backflow by an air gap or backflow preventer in accordance with Section 608. (remainder of section unchanged) 11. Section 413.4 is amended to read as follows: 413.4 Required location for floor drains. Floor drains shall be installed in the following areas with trap primers as required: 1. In public coin-operated laundries and in the central washing facilities of multiple family dwellings, the rooms containing the automatic clothes washers shall be provided with floor drains located to readily drain the entire floor area. Such drains shall have a minimum outlet of not less than 3 inches (76 mm) in diameter; 2. Commercial kitchens. In lieu of floor drains in commercial kitchens, the code official may accept floor sinks; and 3. Public restrooms. 12. Section 502.3 is amended to read as follows: 502.3 Water heaters installed in attics. Attics containing a water heater shall be provided (intervening language unchanged) … side of the water heater. The clear access opening dimensions shall be a minimum 20 inches by 30 inches (508 mm by 762 mm) or larger where such dimensions be not less than 20 inches by 30 inches (508 mm by 762 mm) where such dimensions are large enough to allow removal of the water heater. A walkway to the appliance, shall have continuous solid flooring with a minimum thickness of ½" plywood or ⅝" oriented strand board, and shall be placed over a load bearing wall or with engineered approval. As a minimum, for access to the attic space, provide one of the following: 1. A permanent stair; 2. A pull-down stair with a minimum 300 lbs. (136 kg) capacity; and 3. An access door from an upper floor level. 13. Section 502 is amended by adding Section 502.6 to read as follows: 502.6 Water heaters above ground or floor. When the attic, roof, mezzanine or platform in which a water heater is installed is more than eight (8) feet (2438 mm) above the ground or floor level, it shall be made accessible by a stairway or permanent ladder fastened to the building. Exception: A max 10-gallon water heater (or larger with approval) is capable of being accessed through a lay-in ceiling and a water heater is installed is not more than ten (10) feet (3048 mm) above the ground or floor level and may be reached with a portable ladder. 14. Section 504.6 is amended to read as follows: 504.6 Requirements for discharge piping. The discharge piping serving a pressure relief valve, temperature relief valve or combination thereof shall: 1. Not be directly connected to the drainage system; 2. Discharge through an air gap fitting; 3. Not be smaller than the diameter of the outlet of the valve served and shall discharge full size to the air gap; 4. Serve a single relief device and shall not connect to piping serving any other relief device or equipment; 5. Exception: Multiple relief devices may be installed to a single T & P discharge piping system when approved by the administrative authority and permitted by the manufacturer's installation instructions and installed with those instructions. 6. Discharge to an indirect waste receptor or to the outdoors; 7. Discharge in a manner that does not cause personal injury or structural damage; 8. Discharge to a termination point that is already observable by the building occupants; 9. Not be trapped; 10. Be installed so as to flow by gravity; 11. Terminate not more than 6 inches above and not less than two times the discharge pipe diameter of the floor or flood level rim of the waste interceptor; 12. Not have a threaded connection at the end of such piping; 13. Not have valves or tee fittings; 14. Be constructed of those materials listed in Section 605.4 or materials tested, rated and approved for such use in accordance with ASME A112.4.1; and 15. Be of nominal size larger than the size of the relief valve outlet, where the relief valve discharging piping is installed with insert fittings. The outlet end of such tubing shall be fastened in place. 15. Section 504.7.1 is amended to read as follows: Section 504.7.1 Pan size and drain. The pan shall be not less than 1½ inches (38 mm) in depth and shall be of sufficient size and shape to receive all dripping or condensate from the tank or water heater. The pan shall be drained by an indirect waste pipe having a diameter of not less than ¾ inch (19 mm). Piping for safety pan drains shall be of those materials listed in Table 605.4. Multiple pan drains ma terminate to a single discharge piping system when approved by the administrative authority and permitted by the manufacturer's installation instructions and installed with those instructions. 16. Section 605.3 is amended by adding a paragraph title "Exception" to read as follows: Exception: Where specific materials are required due to the special requirements such as a science lab or industrial use, then the specialty pipe required for that use will be permitted. 17. Section 605.4 is amended by adding a paragraph title "Exception" to read as follows: Exception: Where specific materials are required due to the special requirements such as a science lab or industrial use, then the specialty pipe required for that use will be permitted. 18. Section 605.5 is amended by adding a paragraph title "Exception" to read as follows: Exception: Where specific materials are required due to the special requirements such as a science lab or industrial use, then the specialty pipe fittings required for that use will be permitted. 19. Section 606.1 is amended by deleting numbered paragraphs 4, and 5. 20. Section 608.1 is amended to read as follows: 608.1 General. A potable water supply system shall be designed, installed, and maintained in such a manner so as to prevent contamination from non-potable liquids, solids or gases being introduced into the potable water supply through cross-connections or any other piping connections to the system. Back flow preventer applications shall conform to applicable local regulations, Table 608.1, and as specifically stated in Section 608. 21. Section 608.17.5 change to read as follows: 608.17.5 Connections to lawn irrigation systems. The potable water supply to lawn irrigation systems shall be protected against backflow by an atmospheric-type vacuum breaker, a pressure-type vacuum breaker, a double-check assembly or a reduced pressure principle backflow preventer. A valve shall not be installed downstream from an atmospheric vacuum breaker. Where chemicals are introduced into the system, the potable water supply shall be protected against backflow by a reduced pressure principle backflow preventer. All irrigation systems shall have rain and freeze protection installed. 22. Section 608.18 is amended to read as follows: 608.18 Protection of individual water supplies. An individual water supply shall be located and constructed so as to be safeguarded against contamination in accordance with applicable local regulations. Installation shall be in accordance with Section 608. 23. Section 702.1 is amended by adding a paragraph titled "Exception" to read as follows: Exception: Where specific materials are required due to the special requirements such as a science labfor industrial use, specialty pipe designed for that use will be permitted. 24. Section 703.6 is deleted. 25. Section 704 is amended by adding Section 704.5 to read as follows: 704.5 Single stack fittings. Single stack fittings with internal baffle, single stack shall be designed by a registered engineer and comply to a national recognized standard. 26. Section 712 is amended by adding Section 712.5 to read as follows: 712.5 Dual Pump System. All sumps shall be automatically discharged and, when in any "public use" occupancy where the sump serves more than 10 fixture units, shall be provided with dual pumps or ejectors arranged to function independently in case of overload or mechanical failure. For storm drainage sumps and pumping systems, see Section 1113. 27. Sections 713 is amended by changing the title caption to read "ENGINEERED DRAINAGE DESIGN." 28. Section 713.1 is amended to read as follows: 713.1 Design of drainage system. The sizing requirements for plumbing drainage systems shall be determined by a registered professional engineering using approved design methods. 29. Section 903.1 is amended to read as follows: 903.1 Roof extension. All open vent pipes that extend through a roof shall terminate not less than six(6) inches (152 mm) above the roof. Where the roof is to be used for assembly or as a promenade, observation deck, sunbathing deck or similar purposes, open vent pipes shall terminate not less than 7 feet (2134 mm) above the roof. 30. Section 1002.10 is deleted. 31. Section 1003.3.5.1 is amended in its entirety (inclusive of deleting Table 1003.3.5.1) to read as follows: 1003.3.5.1 Grease Interceptor Capacity. All food establishments having a food disposal or discharge of more than 50 gallons per minute shall discharge into a minimum 750-gallon grease trap. Establishments with a discharge of 50 gallons per minute or less shall discharge into at least a 100-pound size grease trap. An approved-type grease interceptor or grease trap complying with the provisions of this subsection shall be installed in the waste line leading from sinks, drains, and other fixtures or equipment in establishments such as restaurants, cafes, lunch counters, cafeterias, bars and clubs, hotels, hospitals, sanitarium, factory or school kitchens, or other establishments where grease may be introduced into the drainage or sewage system in quantities that can affect line stoppage or hinder sewage treatment or private sewage disposal when grease interceptors are required. All grease traps shall be located outside the building. A grease trap is not required for individual dwelling units or for any private living quarters. 1003.3.5.1.1 Grease Interceptors Minimum Specifications: Grease interceptors shall be constructed as a minimum as follows: 1. Concrete: Shall be composed of one part Portland cement and five parts aggregate. Reinforcement bars deformed number four bars on 18-inch centers; 2. Manholes: Cast iron frame with 20-inch cover; 3. Vents: Four-inch sanitary vent may be reduced to two inches if interceptor is connected to a properly vented sewer or waste line within 25 feet. Relief vents shall be two inches between compartments and to atmosphere above roof, and inside building; 4. Capacity: 750 gallons retention capacity or engineered; and 5. Clean out: Should be two-way located as near as possible to the interceptor on outflow line above seal. 32. Section 1106.1 is amended to read as follows: 1106.1 General. The size of the vertical conductors and leaders, building storm drains, building storm sewers, and any horizontal branches of such drains or sewers shall be based on six (6) inches per hour rainfall rate. 33. Section 1108.3 is amended to read as follows: 1108.3 Sizing of secondary drains. Secondary (emergency) roof drain systems shall be sized in accordance with Section 1106. Scuppers shall be sized to prevent the depth of ponding water from exceeding that for which the roof was designed as determined by Section 1101.7. Scuppers shall not have an opening dimension of less than 4 inches (102 mm). The flow through the primary system shall not be considered when sizing the secondary roof drainage system. 34. Section 1109 is deleted. 35. Section 1202.1 is amended by deleting Exceptions 1 and 2.
(Ord. No. 3919-6-22, § 1, 6-14-2022)
Ask a question about Allen law
Corpus searches the Allen sections it holds and shows the ones that match, with their citations. Free, no sign-in.